4.
O
PERATION
This product is not designed for continual use. Make sure there are regular
breaks during operation to maximize the life of your laser.
Always disconnect the Scorpion™ Storm RGB EU from power when not in use.
A Laser Safety Scanner Board is built-in. Laser light will automatically be turned
off when the scanned angle is less than 2°.
Control Panel
Operation
To access the control panel functions, use the four buttons located underneath the
display. When the product is on, the LED monitor on the rear panel will show the current
operating mode (standalone or DMX). The product will retain the last saved settings when
powered off.
Button
Function
<FUNC>
Selects an operation mode or to backs out of the current menu option
<UP>
Scrolls up the list of options or selects a higher value
<DOWN>
Scrolls down the list of options or selects a lower value
<ENTER>
Activates a menu option or a selected value
Menu Map
Mode
Programming Steps
Description
DMX
001~512
Selects the DMX starting address
Slave
SLA
The slave product follows the actions of
the master product
Sound-Active
Sou
The internal program runs to the beat of
the music (fast or slow)
Automatic
Aut
Automatic fast/slow; automatic sound-
sensitive mode fast/slow
Remote
rEn
Sets the product to operate with the
remote controller
Configuration
(DMX)
Set the product in DMX mode to control with a DMX controller.
1. Connect the product to a suitable power outlet.
2. Turn the product on.
3. Connect a DMX cable from the DMX output of the DMX controller to the DMX input
socket on the product.
Once the DMX cable is connected with the laser and the DMX controller, the DMX
indicator LED on the front panel will be On.
Starting Address
When selecting a starting DMX address, always consider the number of DMX channels
the selected DMX mode uses. If you choose a starting address that is too high, you could
restrict the access to some of the product’s channels.
The Scorpion™ Storm RBG EU uses up to 6 DMX channels in its DMX mode, which
defines the highest configurable address to 507.
If you are unfamiliar with DMX, download the DMX Primer from
www.chauvetlighting.com
.
To select the starting address, do the following:
1. Press
<FUNC>
repeatedly until
001
shows on the display.
2. Press
<ENTER>
.
3. Use
<UP>
or
<DOWN>
to select the starting address.
4. Press
<ENTER>
.