Chauvet Scorpion Storm MG Скачать руководство пользователя страница 7

Scorpion™ Storm MG User Manual 

4/27/2009 5:11 PM

 

 

 
 
 

LASER LIGHT 
AVOID

 

DIRECT

 

EYE

 

EXPOSURE 

 

Further guidelines and safety programs for safe use of lasers can be found in the 

ANSI Z136.1 Standard “For Safe Use of 

Lasers”, available from the Laser Institute of America: www.laserinstitute.org. Many local governments, corporations, 
agencies, military and others, require all lasers to be used under the guidelines of ANSI Z136.1. Laser Display guidance 
can be obtained via the International Laser Display Association: www.laserist.org. 
 

LASER

 

EMISSION

 

DATA 

 

L

ASER 

C

LASSIFICATION

 

C

LASS 

3R

 

(

EQUIV

.

 TO 

US

 

C

LASS 

III

A

)

 

Green Laser Medium

 

DPSS Nd:YVO4, 532nm 

Red Laser Medium

 

LD GaAlAs 650nm, typical 

Beam Diameter 

<5mm at aperture 

Pulse Data 

All pulses < 4Hz (>0.25sec) 
 

Divergence (each beam) 

<2 mrad 

Divergence (total light) 

<160 degrees 

Laser Power of Each 
Beam from Aperture* 

<5

M

 
 
* As measured under IEC measurement conditions for classification. 
 
LASER

 

COMPLIANCE

 

STATEMENT 

 

T

HIS LASER PRODUCT COMPLIES WITH 

EN/IEC

 

60825-1

 

E

2,

 

2007-03,

 AND 

US

 

FDA/CDRH

 

FLPPS

 VIA THE TERMS OF 

L

ASER 

N

OTICE 

N

O

.

 

50

 DATED 

J

UNE 

24,

 

2007.

 

T

HIS LASER DEVICE IS 

C

LASSIFIED 

3R.

 

(C

LASS 

3R

 IS THE INTERNATIONAL EQUIVALENT OF 

US

 

C

LASS 

III

A

).

 

N

O MAINTENANCE IS REQUIRED TO 

KEEP THIS PRODUCT IN COMPLIANCE WITH LASER PERFORMANCE STANDARDS

.

 

 

LASER EXPOSURE WARNING 

 

 

 

Содержание Scorpion Storm MG

Страница 1: ...33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com USER MANUAL Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master Slave Autoswitching Transformer Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...ONS 5 LASER SAFETY LABEL REPRODUCTION 6 AVOID DIRECT EYE EXPOSURE 7 LASER EMISSION DATA 7 LASER COMPLIANCE STATEMENT 7 2 Introduction 8 Features 8 Product Overview 8 Product Dimensions 9 Proper Usage 10 3 Setup 11 Mounting 11 Orientation 11 Rigging 11 4 Operating Instructions 12 Navigating the Control Panel 12 Menu Functions 12 General Troubleshooting 13 Technical Support 14 5 Appendix 14 Returns ...

Страница 3: ...al factory box and packing AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V AC 50 60 Hz All fixtures must be powered directly off a switch...

Страница 4: ...assistance center Always use the same type spare parts Never connect the device to a dimmer pack Make sure the power cord is never crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on Lasers can be hazardous and have unique safety considerations Permanent eye injury and blindness is possible if lasers are ...

Страница 5: ... This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand See Proper Usage section later in this manual After set up and prior t...

Страница 6: ...pion Storm MG User Manual 6 4 27 2009 5 11 PM LASER SAFETY LABEL REPRODUCTION LASER HAZARD WARNING LABEL LASER APERTURE LABEL EXPLANATORY MANUFACTURER S ID CERTIFICATION LABEL NON INTERLOCKED HOUSING LABEL ...

Страница 7: ...ASER CLASSIFICATION CLASS 3R EQUIV TO US CLASS IIIA Green Laser Medium DPSS Nd YVO4 532nm Red Laser Medium LD GaAlAs 650nm typical Beam Diameter 5mm at aperture Pulse Data All pulses 4Hz 0 25sec Divergence each beam 2 mrad Divergence total light 160 degrees Laser Power of Each Beam from Aperture 5MW As measured under IEC measurement conditions for classification LASER COMPLIANCE STATEMENT THIS LAS...

Страница 8: ... and hundreds of beams Pattern and speed knobs for automatic mode Built in automatic programs via master slave Built in sound activated programs via master slave Safety cover protects laser during transport Moveable bracket to allow different mounting positions Complies with FDA CDRH standards for ClassIIIR Product Overview Power LED Hanging bracket Bracket adjustment knob 1 of 2 Audio LED ...

Страница 9: ...Scorpion Storm MG User Manual 9 4 27 2009 5 11 PM PRODUCT DIMENSIONS ...

Страница 10: ...ms appropriate for safe and effective mounting are easily sourced from your lighting vendor International laser safety regulations require that lasers must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 2 5 meters of horizontal separation is required between laser light and a...

Страница 11: ... fan or vents pathway Mount the fixture using a suitable C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration access and routine maintenance Safety cables must always be used Never mount in places where the fixture will be exposed to rain...

Страница 12: ...on and speed second digit All programs can further be altered and customized by rotating the 2 motor knobs below the display These will not work in master slave operation Select any of these automatic programs to constantly change effects patterns speeds etc These programs do not have manual adjustment and will not work with the motor knobs below the display These programs will work in master slav...

Страница 13: ...e on the control switches If audio provided via jack make sure a live audio signal exists Adjust sound sensitivity knob Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated ...

Страница 14: ...k fixture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 ...

Страница 15: ... to adapter Fuse 1 5A 250V slow blow Power Consumption 11W 0 1A max 120V Inrush Power 0 2A 120V Power Output 75 units max 120V LASER Green diode 532 nm 30mW Laser Type DPSS Cooling Fan Cooled RANGE Coverage Angle 100 THERMAL Maximum ambient temperature 104 F 40 C MASTER SLAVE LINKING Cable type male to male 1 8 3 5mm TRS cable ORDERING INFORMATION Scorpion Storm MG SCORPIONSTORMMG WARRANTY INFORMA...