background image

  

Appendix 

 

DMX Quick Reference Chart 

DMX Address Quick Reference Chart 

Dip Switch Position 

DMX DIP SWITCH 

SET 

#9  0 0 0 0  0 0 0 0 1 1 1 1 1 1 1 1 

0=OFF #8 

0 0 0 0  1 1 1 1 0 0 0 0 1 1 1 1 

1=ON #7 

0 0 1 1  0 0 1 1 0 0 1 1 0 0 1 1 

X=OFF or ON 

#6  0 1 0 1  0 1 0 1 0 1 0

 

0 1 0 1 

#1 #2 #3 #4 #5 

 

0 0 0 0 0    32 

64 96  128

160

192

224

256

288

320

352

384 416 448

480

1 0 0 0 0  1 33 65 97  129

161

193

225

257

289

321

353

385 417 449

481

0 1 0 0 0  2 34 66 98  130

162

194

226

258

290

322

354

386 418 450

482

1 1 0 0 0  3 35 67 99  131

163

195

227

259

291

323

355

387 419 451

483

0 0 1 0 0  4 36 68 100

132

164

196

228

260

292

324

356

388 420 452

484

1 0 1 0 0  5 37 69 101

133

165

197

229

261

293

325

357

389 421 453

485

0 1 1 0 0  6 38 70 102

134

166

198

230

262

294

326

358

390 422 454

486

1 1 1 0 0  7 39 71 103

135

167

199

231

263

295

327

359

391 423 455

487

0 0 0 1 0  8 40 72 104

136

168

200

232

264

296

328

360

392 424 456

488

1 0 0 1 0  9 41 73 105

137

169

201

233

265

297

329

361

393 425 457

489

0 1 0 1 0  10 42 74 106

138

170

202

234

266

298

330

362

394 426 458

490

1 1 0 1 0  11 43 75 107

139

171

203

235

267

299

331

363

395 427 459

491

0 0 1 1 0  12 44 76 108

140

172

204

236

268

300

332

364

396 428 460

492

1 0 1 1 0  13 45 77 109

141

173

205

237

269

301

333

365

397 429 461

493

0 1 1 1 0  14 46 78 110

142

174

206

238

270

302

334

366

398 430 462

494

1 1 1 1 0  15 47 79 111

143

175

207

239

271

303

335

367

399 431 463

495

0 0 0 0 1  16 48 80 112

144

176

208

240

272

304

336

368

400 432 464

496

1 0 0 0 1  17 49 81 113

145

177

209

241

273

305

337

369

401 433 465

497

0 1 0 0 1  18 50 82 114

146

178

210

242

274

306

338

370

402 434 466

498

1 1 0 0 1  19 51 83 115

147

179

211

243

275

307

339

371

403 435 467

499

0 0 1 0 1  20 52 84 116

148

180

212

244

276

308

340

372

404 436 468

500

1 0 1 0 1  21 53 85 117

149

181

213

245

277

309

341

373

405 437 469

501

0 1 1 0 1 

22 54 86 118

150

182

214

246

278

310

342

374

406 438 470

502

1 1 1 0 1 

23 55 87 119

151

183

215

247

279

311

343

375

407 439 471

503

0 0 0 1 1 

24 56 88 120

152

184

216

248

280

312

344

376

408 440 472

504

1 0 0 1 1 

25 57 89 121

153

185

217

249

281

313

345

377

409 441 473

505

0 1 0 1 1 

26 58 90 122

154

186

218

250

282

314

346

378

410 442 474

506

1 1 0 1 1 

27 59 91 123

155

187

219

251

283

315

347

379

411 443 475

507

0 0 1 1 1 

28 60 92 124

156

188

220

252

284

316

348

380

412 444 476

508

1 0 1 1 1 

29 61 93 125

157

189

221

253

285

317

349

381

413 445 477

509

0 1 1 1 1 

 

30 62 94 126

158

190

222

254

286

318

350

382

414 446 478

510

1 1 1 1 1  31 63 95 127

159

191

223

255

287

319

351

383

415 447 479

511

Dip Switch Position                            DMX  Address 

LG-60 User Manual

 

14 

11/14/2007 6:04:00 PM 

Содержание Scorpion Scan LG-60

Страница 1: ...LG 60 Scorpion Scan USER MANUAL CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com ...

Страница 2: ...ART 9 DMX MODE 10 Setting the starting address 10 OPERATION 11 Stand Alone Operation Sound_Active Auto Mode 11 Master Slave Operation Master_Sound Master_Auto 11 Universal DMX Control DMX Mode 12 APPENDIX 13 DMX PRIMER 13 Fixture Linking 13 DMX QUICK REFERENCE CHART 14 DMX CHANNEL VALUES 15 TROUBLESHOOTING 15 DYNAMIC PATTERNS DMX VALUES 16 STATIC PATTERNS DMX VALUES 17 GENERAL MAINTENANCE 18 RETUR...

Страница 3: ...k plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture che...

Страница 4: ...wer source before servicing or replacing lamp or fuse and be sure to replace with same lamp source Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature is Ta 35 Do not operate fixture at temperatures higher than this In the event of serious operating problem stop using the unit immediately Never try ...

Страница 5: ...w acceptable levels for human ocular or tissue exposure Features CONTROL FEATURES 7 channel DMX controlled green laser 51 Dynamic 52 Static patterns Laser off sound active mode Scan and speed adjustment yields 500 laser effects 74 patterns in sound active mode 52 patterns in auto mode Laser On Off green X and Y position adjustment of laser effect Dynamic Scan speed adjust Dynamic pattern speed adj...

Страница 6: ...g the unit to AC power make certain that the front aperture is pointed away from you or others Fan Sound Sensitivity Knob Dipswitch settings for DMX addressing other functions DMX connectors Switch selectable power AC Power Input Power Switch LG 60 User Manual 6 11 14 2007 6 04 00 PM ...

Страница 7: ...tructions Please do not return the unit to your dealer without first contacting CHAUVET customer support Notice 1 Please insure the power supply has good connect with ground before operating the unit in order to prevent electrical shock 2 This system is intended to only be operated indoors Avoid any direct contact with water and make certain the unit is firmly mounted 3 Ensure the operating temper...

Страница 8: ...ooled Output 20mW Beam Diameter at aperture 10 14mm Beam Divergence Optically adjusted for compliance Radiant Exposure at Aperture 4 95mW 7mm Human Limiting Aperture There is only one laser aperture on this product CAUTION AVOID EXPOSURE TO BEAM Avoid direct eye contact with laser light Never intentionally expose your eyes or others to direct laser radiation Non Interlocked Housing Warning Labels ...

Страница 9: ...er than what is specified herein may result in hazardous radiation exposure CONTROL FUNCTION nits function DMX address and DMX MODE of function Each Dipswitch C This unit uses dipswitches to assign a u dipswitch represents a binary value hart DIPSWI 0 OFF 1 ON X 0FF or ON TCH CHART FUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 X X X X 0 0 0 S X X X X X OUND ACTIVE X X X X X X X X X 0 0 1 AUTO DE MO X X X X ...

Страница 10: ...eading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the ON position will provide the start address Determining which switches to toggle ON given a specific start address can be accomplished ...

Страница 11: ...UND AUTO Master Slave Operation Master_Sound Master_Auto This mode will allow you to link up to 32 units together without controller 1 Use standard XLR DMX cables to daisy chain your units together via the XLR connector on the rear of the units For longer cable runs we suggest a terminator at the last fixture 2 Choose a unit to function as Master mode Turn dipswitches to the Master position on the...

Страница 12: ...onnector on the rear of the units For long cable runs we suggest a terminator on the last fixture Mode Dipswitches DMX mode 10 On 11 Off 12 On 2 Assign a DMX address to the unit by following the dipswitch chart 3 Use DMX controller to control your units OUT IN POWER 1 DMX 2 DMX N DMX DMX 512 Note System doesn t use DMX controller in Master Slave Mode System may not set to two Master units in Maste...

Страница 13: ...the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is D...

Страница 14: ...109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 4...

Страница 15: ...n system is set up in Master Slave mode 3 If it is in Master Slave mode Slave mode is exceptional please check as below A Make sure to set up Master mode for just one unit and the others are set in slave mode B Make sure to control the unit with DMX controller C Make sure to take a good quality power cord and connection 4 If the unit is in DMX mode the laser cannot be controlled by the DMX control...

Страница 16: ...Appendix Dynamic Patterns DMX Values LG 60 User Manual 16 11 14 2007 18 04 ...

Страница 17: ...Appendix Appendix LG 60 User Manual 17 11 14 2007 6 04 00 PM Static Patterns DMX Values LG 60 User Manual 17 11 14 2007 6 04 00 PM ...

Страница 18: ...it s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA P...

Страница 19: ...S Laser Output 20mW Cooling Fan Cooled CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 7 ORDERING INFORMATION Scorpion Scan LG 60 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone ...

Отзывы: