background image

LG-60

Scorpion™ Scan

 

 

USER MANUAL

 

CHAUVET, 3000 N 29

th

 Ct, Hollywood, FL 33020 U.S.A  

(800) 762-1084 – (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com 

Содержание Scorpion Scan LG-60

Страница 1: ...LG 60 Scorpion Scan USER MANUAL CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com ...

Страница 2: ...ART 9 DMX MODE 10 Setting the starting address 10 OPERATION 11 Stand Alone Operation Sound_Active Auto Mode 11 Master Slave Operation Master_Sound Master_Auto 11 Universal DMX Control DMX Mode 12 APPENDIX 13 DMX PRIMER 13 Fixture Linking 13 DMX QUICK REFERENCE CHART 14 DMX CHANNEL VALUES 15 TROUBLESHOOTING 15 DYNAMIC PATTERNS DMX VALUES 16 STATIC PATTERNS DMX VALUES 17 GENERAL MAINTENANCE 18 RETUR...

Страница 3: ...k plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture che...

Страница 4: ...wer source before servicing or replacing lamp or fuse and be sure to replace with same lamp source Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature is Ta 35 Do not operate fixture at temperatures higher than this In the event of serious operating problem stop using the unit immediately Never try ...

Страница 5: ...w acceptable levels for human ocular or tissue exposure Features CONTROL FEATURES 7 channel DMX controlled green laser 51 Dynamic 52 Static patterns Laser off sound active mode Scan and speed adjustment yields 500 laser effects 74 patterns in sound active mode 52 patterns in auto mode Laser On Off green X and Y position adjustment of laser effect Dynamic Scan speed adjust Dynamic pattern speed adj...

Страница 6: ...g the unit to AC power make certain that the front aperture is pointed away from you or others Fan Sound Sensitivity Knob Dipswitch settings for DMX addressing other functions DMX connectors Switch selectable power AC Power Input Power Switch LG 60 User Manual 6 11 14 2007 6 04 00 PM ...

Страница 7: ...tructions Please do not return the unit to your dealer without first contacting CHAUVET customer support Notice 1 Please insure the power supply has good connect with ground before operating the unit in order to prevent electrical shock 2 This system is intended to only be operated indoors Avoid any direct contact with water and make certain the unit is firmly mounted 3 Ensure the operating temper...

Страница 8: ...ooled Output 20mW Beam Diameter at aperture 10 14mm Beam Divergence Optically adjusted for compliance Radiant Exposure at Aperture 4 95mW 7mm Human Limiting Aperture There is only one laser aperture on this product CAUTION AVOID EXPOSURE TO BEAM Avoid direct eye contact with laser light Never intentionally expose your eyes or others to direct laser radiation Non Interlocked Housing Warning Labels ...

Страница 9: ...er than what is specified herein may result in hazardous radiation exposure CONTROL FUNCTION nits function DMX address and DMX MODE of function Each Dipswitch C This unit uses dipswitches to assign a u dipswitch represents a binary value hart DIPSWI 0 OFF 1 ON X 0FF or ON TCH CHART FUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 X X X X 0 0 0 S X X X X X OUND ACTIVE X X X X X X X X X 0 0 1 AUTO DE MO X X X X ...

Страница 10: ...eading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the ON position will provide the start address Determining which switches to toggle ON given a specific start address can be accomplished ...

Страница 11: ...UND AUTO Master Slave Operation Master_Sound Master_Auto This mode will allow you to link up to 32 units together without controller 1 Use standard XLR DMX cables to daisy chain your units together via the XLR connector on the rear of the units For longer cable runs we suggest a terminator at the last fixture 2 Choose a unit to function as Master mode Turn dipswitches to the Master position on the...

Страница 12: ...onnector on the rear of the units For long cable runs we suggest a terminator on the last fixture Mode Dipswitches DMX mode 10 On 11 Off 12 On 2 Assign a DMX address to the unit by following the dipswitch chart 3 Use DMX controller to control your units OUT IN POWER 1 DMX 2 DMX N DMX DMX 512 Note System doesn t use DMX controller in Master Slave Mode System may not set to two Master units in Maste...

Страница 13: ...the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is D...

Страница 14: ...109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 4...

Страница 15: ...n system is set up in Master Slave mode 3 If it is in Master Slave mode Slave mode is exceptional please check as below A Make sure to set up Master mode for just one unit and the others are set in slave mode B Make sure to control the unit with DMX controller C Make sure to take a good quality power cord and connection 4 If the unit is in DMX mode the laser cannot be controlled by the DMX control...

Страница 16: ...Appendix Dynamic Patterns DMX Values LG 60 User Manual 16 11 14 2007 18 04 ...

Страница 17: ...Appendix Appendix LG 60 User Manual 17 11 14 2007 6 04 00 PM Static Patterns DMX Values LG 60 User Manual 17 11 14 2007 6 04 00 PM ...

Страница 18: ...it s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA P...

Страница 19: ...S Laser Output 20mW Cooling Fan Cooled CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 7 ORDERING INFORMATION Scorpion Scan LG 60 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone ...