background image

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

User Manual 

 

Содержание Obsession LED

Страница 1: ...User Manual ...

Страница 2: ...INSTRUCTIONS 4 2 INTRODUCTION 5 PRODUCT OVERVIEW 5 3 SETUP 6 AC POWER 6 Power Linking 6 MOUNTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 CONFIGURING THE STARTING ADDRESS 8 DMX Operation 8 Master Slave Mode Sound Active Auto Mode 8 Standalone 9 DMX CHANNEL VALUES 9 5 APPENDIX 10 GENERAL TROUBLESHOOTING 10 DMX PRIMER 11 FIXTURE LINKING DAISY CHAIN 11 DATA CABLING 11 DMX Data Cable 11 CA...

Страница 3: ...regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This m...

Страница 4: ...ect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by u...

Страница 5: ...2010 2 38 PM 2 INTRODUCTION Product Overview DMX In DIP Switches Bracket Adjustment Knob Safety Bracket Adjustment Knob Power In Mounting Bracket Power Out Fuseholder DMX Out Microphone Sensitivity Adjustment Knob Microphone ...

Страница 6: ...uit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the Edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum quantity of Obsession LED fixtures that may be linked is 40 The power ...

Страница 7: ...ze When rigging consider routine maintenance and control panel access Please see the following notes on installation If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this When aiming the fixtures you may use the bracket adjustment knob Loosen the knob adjust to t...

Страница 8: ...peration This is the operating mode which will allow for control with an external DMX controller You must set the starting address for this mode If this is your first time using DMX then it is recommended that you refer to the DMX Primer section in the Appendix of this manual Mode DIP switches DMX 1 9 set to the DMX starting address 10 On Master Slave Mode Sound Active Auto Mode This mode allows a...

Страница 9: ...s is accessed via the DIP switches on the back of the fixture Use the microphone sensitivity adjustment knob to control the sensitivity of music in this mode DIP switch 10 must be OFF in this mode DIP switch 9 must be OFF Please see the chart below for further explanation Mode Mirror Dish Rotating Mirror Dish Static Gobo Wheel Rotating Gobo Wheel Static DIP switches 1 ON 1 OFF 2 ON 2 OFF DMX Chann...

Страница 10: ...ng Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier r...

Страница 11: ...e pin 2 is Data Negative S and pin 3 is Data positive S Fixture Linking Daisy Chain You will need a daisy chain to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a daisy chain determines the number of fixtures the data link can su...

Страница 12: ...o read the data on the channel indicated by the start address For example a fixture that uses six DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and note the start address selected for future reference If this is your first time addressing a fixture using the DMX co...

Страница 13: ...n 4 Not used Pin 5 Setting up a DMX Daisy Chain 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to connect from the output as stated above to ...

Страница 14: ...0 days Clean the fixture at least every 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAUV...

Страница 15: ...s max LIGHT SOURCE Type high power single source LED Quantity 1 Rating white 10 W 2 8 A 50 000 hrs PHOTO OPTIC Coverage angle 33 INDOOR OUTDOOR Rating For indoor use only THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR female socket Data output locking 3 pin XLR male socket Data pin configuration pin 1 shield pin 2 pin 3 Protocol DMX 512 USITT DMX Ch...

Страница 16: ...0 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 Press 4 fax 954 929 5560 Attention Service World Wide Web www chauvetlighting com ...

Отзывы: