Chauvet MiN Spot Скачать руководство пользователя страница 3

 

1.

 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

¾

 

1 x MinSpot™ 

¾

 

Power Cord  

¾

 Warranty 

Card 

¾

 User 

Manual 

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 
all parts are present, and have been received in good condition. Notify the shipper immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 
must be returned to the factory, it is important that the fixture be returned in the original factory box 
and packing. 

AC Power 

Figure 1 - AC Voltage Switch 

Not all fixtures have a voltage 
select switch. Please be sure to 
connect to the proper voltage. 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average 
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and 
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer 
channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the 
source voltage matches the fixture’s requirement. Check the fixture or 
device carefully to make sure that if a voltage selection switch exists that it 
is set to the correct line voltage you will use. 

Warning! 

Verify that the voltage select switch on your unit matches the 
line voltage applied. Damage to your fixture may result if the 
line voltage applied does not match the voltage indicated on 
the voltage selector switch. All fixtures must be connected to 
circuits with a suitable Earth Ground.  

Contact Us 

W o rld   Wid e 

General Information

 

Chauvet Lighting 
3000 North 29

th

 Court 

Hollywood, FL 33020 
voice: 954.929.1115 
fax: 954.929.5560 
toll free:  800.762.1084 

Technical Support

 

Chauvet Lighting 
3000 North 29

th

 Court 

Hollywood, FL 33020 
voice: 954.929.1115

 (Press 4)

 

fax: 954.929.5560

 (Attention: Service)

 

World Wide Web 

www.chauvetlighting.com 

MinSpot 3 

2007-08-23/15:49

 

Содержание MiN Spot

Страница 1: ...Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle MiNSpot USER MANUAL Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954...

Страница 2: ...FIGURATIONS 12 To set the pan to inverting or non inverting 12 To set the tilt to inverting or non inverting 12 To set the LED Readout to Inverting or Non Inverting 12 To set the DMX channel configura...

Страница 3: ...verage current draw under normal conditions All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or di...

Страница 4: ...ource before servicing or replacing fuse and be sure to replace with same fuse size and type Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its...

Страница 5: ...AL FEATURES User selectable basic or advanced operating modes User selectable pan tilt ranges Pan 540 360 180 Tilt 270 180 90 Compact and lightweight LED display menu with invert Reset to factory sett...

Страница 6: ...1 Pan 2 Tilt 3 Shutter 4 Color Macro 5 Gobo Product Overview Projector Head Lens Focus LED Readout Control Panel DMX In DMX Out IEC Power Connector with Fuse holder Rear Voltage Selector Switch rear C...

Страница 7: ...data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended seria...

Страница 8: ...not allow contact between the common and the fixture s chassis ground Grounding the common verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each othe RSI...

Страница 9: ...a male 3 pin connector Then ounting RIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING It is important never to obstruct the fan or vents pa...

Страница 10: ...ER DOWN UP MODE ESC The Control Panel LED Display shows the menu items you select from the menu map on page 11 When a menu function is selected the display will show immediately the first available op...

Страница 11: ...Menu Map MinSpot 11 2007 08 23 15 49...

Страница 12: ...CHANNEL CONFIGURATION 1 Press the Mode button until it shows or 2 Use the Up Down buttons to set to the desired inversion press enter to confirm TO SET THE MAXIMUM PAN ANGLE 1 Press the Mode button un...

Страница 13: ...ture For more information about terminators see page 8 2 Choose a unit to function as the Master Select NAFA NASL or NStS see below for readout depending upon which master mode you require The master...

Страница 14: ...reen Light Blue Teal Sky Blue Blue Olive Turquoise Orange Yellow Magenta White Color Change Macro 1 Color Change Macro 2 Color Change Macro 3 Color Change Macro 4 11 000 255 Vector Speed Color 12 000...

Страница 15: ...127 128 139 140 151 152 163 164 175 176 187 188 199 200 212 213 225 226 239 240 255 Color Macros No Function Magenta Purple Orange Pink Yellow Pale Green Light Blue Teal Sky Blue Blue Olive Turquoise...

Страница 16: ...rmine the largest value switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest va...

Страница 17: ...7 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0...

Страница 18: ...of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before po...

Страница 19: ...of the fixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison m...

Страница 20: ...y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags...

Страница 21: ...GHT SOURCE LED 1 14W RGB 50 000hrs PHOTO OPTIC Beam Angle 13 Illuminance at 1M 100 fc 1 076 lux RANGE Pan 540 Tilt 270 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input loc...

Отзывы: