Chauvet MiN Laser FX Скачать руководство пользователя страница 11

 
4. Operating Instructions 

11 

12/7/2010 9:44 AM  

4.

 

O

PERATING 

I

NSTRUCTIONS

 

 

 

Manual Mode 

 

 

 

Access the five different operating modes available in this fixture by using the 

<MODE>

 button on the front panel. 

 
Press 

<MODE>

 to cycle through the modes. Please see a description of each mode below. 

 

 

 

Mode Description 

 

 1 Sound-active 

 

 

Sound-active B 

 

 

Automatic A (constant rotation-slow) 

 

 

Automatic B (stepping rotation-back and forth) 

 

 

Automatic C (constant rotation-fast) 

 

 

 

 

The LED indicator on the front of the fixture will be green when a sound-active mode is selected. 

 

 

 

The LED indicator on the front of the fixture will be red when an automatic mode is selected. 

 

 

Wireless Remote (IR) 

 

 

 

 

Auto Programs 

 

 

 

Auto Program 

Description 

 

Static Effect (red & green on) 

 

Slow rotation (red & green on) 

 

Slow rotation (red & green strobing) 

 

Medium rotation (red & green on) 

 

Medium rotation (red & green strobing) 

 

Fast rotation (red & green on)

 

 

Fast rotation (red & green strobing)

 

 

Programmed rotation (red & green on)

 

 

Programmed rotation (red & green strobing)

 

 

 

 

 

The wireless Remote (IR) will immediately override the <MODE> button. No additional settings are required! 

 

 

Cycles through all 9 of 

the auto programs 

with the built-in timing 

Both Lasers will be on 

in all programs. 

Press to activate one of 

the 9 auto programs 

Cycles through all 9 of 
the auto programs to 
the beat of the music

Turn the laser on/off

Only the green laser 
will be on in all 
programs 

Only the red laser will 

be on in all programs 

Содержание MiN Laser FX

Страница 1: ... User Manual ...

Страница 2: ...EGIN 3 WHAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 MANUAL CONVENTIONS 3 ICONS 3 SAFETY INSTRUCTIONS 4 LASER SAFETY AND OPERATING INSTRUCTIONS 5 LASER SAFETY LABEL REPRODUCTION 6 LASER EMISSION DATA 7 LASER COMPLIANCE STATEMENT 7 2 INTRODUCTION 8 PRODUCT OVERVIEW 8 3 SETUP 9 AC POWER 9 MOUNTING 10 Orientation 10 Rigging 10 4 OPERATING INSTRUCTIONS 11 MANUAL MODE 11 WIRELESS REMOTE IR 11 5 APPENDIX ...

Страница 3: ...tain types of information from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to ...

Страница 4: ...mped or damaged Never disconnect the power cord by pulling or tugging on the cord Never carry the fixture directly from the cord Always use the hanging mounting bracket Avoid direct eye exposure to the light source while it is on Lasers can be hazardous and have unique safety considerations Permanent eye injury and blindness is possible if lasers are used incorrectly Pay close attention to each sa...

Страница 5: ... safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand See Proper Usage section later in this manual After set up and prior to public use test laser to ensure proper function Do not use if any defect is detected Do not use if laser emits only one or two laser beams rather ...

Страница 6: ...1 Before You Begin 6 12 7 2010 9 44 AM Laser Safety Label Reproduction Front Rear Top Bottom ...

Страница 7: ... Classification Class 3R equiv to US Class IIIa Green Laser Medium DPSS Nd YVO4 532 nm Red Laser Medium LD GaAIAs 650 nm Beam Diameter 5mm at aperture Pulse Data All pulses 4 Hz 0 25 sec Divergence each beam 2 mrad Divergence total light 160 degrees Laser Power of Each Beam from Aperture 5 mW As measured under IEC measurement conditions for classification Laser Compliance Statement This laser prod...

Страница 8: ...2 Introduction 8 12 7 2010 9 44 AM 2 INTRODUCTION Product Overview Laser Output Mode Button Microphone LED Indicator Wireless Remote Receiver Cooling Fan Green Laser Dimmer 12 V Power In ...

Страница 9: ...particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a switched circuit Never connect the fixture to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to...

Страница 10: ...fixture securely Do this with a screw nut and bolt or a hanging clamp When rigging consider routine maintenance Please see the following notes on installation When aiming the fixtures you may use the bracket adjustment knob s Loosen the knob s adjust to the desired angle and then tighten the knob s by turning clockwise Do not use tools for this step as it may cause damage Use the floor stand to su...

Страница 11: ...omatic mode is selected Wireless Remote IR Auto Programs Auto Program Description 1 Static Effect red green on 2 Slow rotation red green on 3 Slow rotation red green strobing 4 Medium rotation red green on 5 Medium rotation red green strobing 6 Fast rotation red green on 7 Fast rotation red green strobing 8 Programmed rotation red green on 9 Programmed rotation red green strobing The wireless Remo...

Страница 12: ...ddressing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install ampl...

Страница 13: ... days Clean the fixture at least every 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAUVE...

Страница 14: ...THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input wireless remote included ORDERING INFORMATION MiN Laser FX MINLASERFX MiN Laser RGX MINLASERRGX MiN Laser STAR MINLASERSTAR Wireless Remote MiN Laser IR WARRANTY INFORMATION Warranty fixture excluding the laser diodes 1 year limited warranty Warranty laser diodes 90 day limited warranty CONTACT US WORLD WIDE General Info...

Отзывы: