background image

 
5. Appendix 

16 

1/6/2010 11:34 AM 

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing; call tags will not be issued. 

Package must be clearly labeled with a Return Merchandize Authorization Number (RMA #). 

Products returned without the RMA # will be refused. Call CHAUVET® and request an RMA # prior to 

shipping the fixture. Be prepared to provide the model number, serial number and a brief description 

of the cause for the return. Be sure to pack fixture properly; any shipping damage resulting from 

inadequate packaging is th

e customer’s responsibility. As a suggestion, proper UPS packing or 

double-boxing is always a safe method to use.  

CHAUVET® reserves the right to use its own discretion to repair or replace product(s). 

If you are given an RMA #, please include the following information on a piece of paper inside 
the box:

 

 

1) 

Your name 

2) 

Your address 

3) 

Your phone number 

4) 

The RMA # 

5) 

A brief description of the symptoms 

 

Claims 

Damage incurred in shipping is the responsibility of the shipper; therefore, the damage must be 

reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and 

submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any other claim 

for items such as missing component/part, damage not related to shipping, and concealed damage, 

must be made within seven (7) days of receiving merchandise.

 

Содержание Line Danser LED

Страница 1: ... 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...REAR PANEL 6 3 SETUP 7 AC POWER 7 Power Linking 7 MOUNTING 8 Orientation 8 Rigging 8 4 OPERATING INSTRUCTIONS 9 CONFIGURING THE STARTING ADDRESS 9 DMX OPERATION 9 MASTER SLAVE 9 STANDALONE OPERATION 10 Automatic 10 Sound Active 10 Custom Static Color Mixing 10 DMX CHANNEL VALUES 10 Fixture Linking 11 5 APPENDIX 12 DMX PRIMER 12 GENERAL MAINTENANCE 12 DATA CABLING 13 DMX Data Cable 13 Cable Connect...

Страница 3: ... regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This ...

Страница 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by un...

Страница 5: ...nnel DMX 512 LED effect light Individual control of red green and blue LEDs Variable speed of motor Built in automated programs via master slave or DMX Built in sound activated programs via master slave or DMX Additional Features Additional power output max 30 units ...

Страница 6: ... Overview rear panel Single yoke Hanging Standing Brackets 2 Bracket Adjustment Knobs 2 Signal Indicator LED Sound Sensitivity Adjustment Knob Microphone Power Link Out Power In Fuseholder DMX In DMX Out Safety Attachment Point DIP Switches Power Indicator LED ...

Страница 7: ...00 switch To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the ed...

Страница 8: ...done with a screw nut and bolt or a hanging clamp The hole in each bracket is 13 mm in size When rigging consider routine maintenance and control panel access Please see the following steps for installation If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this Wh...

Страница 9: ...time using DMX then it is recommended that you refer to the DMX Primer section in the Appendix of this manual 1 Plug the DMX controller into the fixture 2 Using the DIP switches 1 9 assign the DMX starting address The blue LED located directly to the right of the DIP switches will blink rapidly when the fixture detects DMX signal This fixture will switch to DMX mode automatically when a DMX contro...

Страница 10: ...Static Color Mixing This fixture has the ability to accept custom settings These are accessed via the DIP switches Please see the list below for these DIP switch settings Function DIP switch Red 1 Green 2 Blue 3 Strobe Speed 4 8 The rotation speed is fixed to the default setting in this mode It is not possible to adjust this speed in standalone operation DMX Channel Values CHANNEL VALUE FUNCTION 1...

Страница 11: ...this fixture in a DMX or master slave operation you must daisy chain using DMX cables to link from one fixture to another In a master slave operation the DMX controller is not connected Additional signal link out DMX controller only in DMX operation Fixture 1 Fixture 2 Fixture 3 ...

Страница 12: ...e with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up ...

Страница 13: ...your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number...

Страница 14: ... CHART Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not used Pin 4 Not used Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connect...

Страница 15: ...l wiring internal and or external Device does not power up No power Check for power on power outlet Loose power cord Check power cord Fixture is not responding to DMX Wrong DMX addressing Check Control Panel and unit addressing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faul...

Страница 16: ... UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of ...

Страница 17: ...0 VAC 50 60 Hz Power Consumption 120 VAC 60 Hz 8 W 0 2 A max 0 2 A inrush Power Consumption 230 VAC 50 Hz 10 W 0 1 A max 0 2 A inrush Power output 30 units max Fuse F 2 A 250 V LIGHT SOURCE LED 72 24 red 24 green 24 blue 100 000 hrs PHOTO OPTIC Coverage Angle 70 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION Line Dancer LED LINCEDANCERLED WARRANTY INFORMATION Warranty 2 year l...

Отзывы: