![Chauvet LEG-4500 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/chauvet/leg-4500/leg-4500_user-manual_2593536013.webp)
Legend™ 4500 User Manual
13
12/10/2008 4:28 PM
4.
O
PERATING
I
NSTRUCTIONS
Control Options
The
Legend™ 4500 is addressable in the DMX range of 001 to 512. In its simplest control form,
this allows for the control of up to 36 fixtures in the 14-channel Advanced personality.
DMX-512 control
The
Legend™ 4500 operates on 14 channels of DMX (“Advanced” personality). Address each
fixture in increments of 14 channels. (I.e. 1,15,29,43,
etc…) To save time you can use the same
DMX address for each fixture. All fixtures will then respond simultaneously to control. You may
also group your fixtures and address those groups alike for faster programming and control.
1. Access the control panel function by pressing the (
MENU
) button until the {
1.4 OPERATION
}
is displayed.
2. Press (
ENTER
) and use the (
UP/DOWN
) buttons to select
{DMX}
function. Press (
ENTER
).
3. Then, Press (
MENU
) button and use the (
UP/DOWN
) buttons
until {
ADDRESS
} is displayed.
4. Pres the (
ENTER
) button.
6. Use the (
UP/DOWN
) buttons to increase or decrease channels between 001 and 512.
7. Press the (
ENTER
) button to confirm action. Then press (
MENU
) to exit.