Appendix
LEG-3000 Manual
15
Revision: 2006-01-20/16:03
Service Functions
{
} - F i x t u r e R e s e t ( a l l m o t o r s )
This function will re-initialize the fixture by returning all motors to its startup positions or otherwise
known as (home position).
F
UNCTION
S
ET
T
O
N
OTES
Off
Normal
On
Reset all motors
{
} - F i x t u r e R e s e t ( e x c l u d e s P a n & T i l t )
This function will re-initialize the fixture with exception of the Pan and Tilt motors.
F
UNCTION
S
ET
T
O
N
OTES
Off
Normal
On
Reset unit
{
}
–
L a m p T i m e
The (lamp time) readout displays the number of hours the lamp has been in use. It is not uncommon
to find new fixtures with a few logged hours. This means the fixture was thoroughly tested prior to
delivery.
1. Press the [
◄
MENU] button until the display reads
“
”
.
2. Press [
▼
SELECT] button to read the number of hours used.
3. Press both [
▼▲
SELECT]
buttons at the same time to reset the lamp counter to zero if changing
a lamp.
{
}
–
F i x t u r e T i m e r
The (Fixture Timer) readout displays the total number of operating hours of the fixture. It is not
uncommon to find new fixtures with a few logged hours.