background image

LEDSplash 86B User Manual 

Rev. 3 

1.

 

B

EFORE 

Y

OU 

B

EGIN

 

What is Included 

 

1 x LEDsplash™ 86B 

 

1 x Warranty Card 

 

1 x User Manual 

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 
all parts are present, and have been received in good condition. Notify the shipper immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 
must be returned to the factory, it is important that the fixture be returned in the original factory box 
and packing. 

Manual Conventions 

CHAUVET® manuals use the following conventions to differentiate certain types of information from 
the regular text. 

C

ONVENTION

 

M

EANING

 

[10] 

A DIP switch to be configured  

<Menu> 

A key to be pressed on the fixture’s control panel 

1~512 

A range of values 

50/60 

A set of values of which only one can be chosen 

Settings 

A menu option not to be modified (for example, showing the operating 
mode/current status) 

MENU >

 

Settings

 

A sequence of menu options to be followed 

ON 

A value to be entered or selected 

 

Icons 

This manual uses the following icons to indicate information that requires special attention on the part 
of the user. 

I

CONS

 

M

EANING

 

 

Critical installation, configuration or operation information. Failure to 
comply with this information may render the fixture partially or completely 
inoperative, cause damage to the fixture or cause harm to the user. 

 

Important installation or configuration information. Failure to comply with 
this information may prevent the fixture from functioning correctly. 

 

Useful non-critical information. 

 

 

Содержание LEDsplash 86B

Страница 1: ...L 33351 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...gging 6 4 OPERATING INSTRUCTIONS 8 CONFIGURING THE STARTING ADDRESS 8 DMX OPERATION 8 ACCESSING THE 2 PERSONALITIES 8 MASTER SLAVE MODE SOUND ACTIVE AUTO MODE STATIC COLORS 8 STROBE SPEED 8 STANDALONE OPERATION 8 Automatic 8 Sound Active 9 Static Colors 9 DMX CHANNEL VALUES 9 5 APPENDIX 10 GENERAL MAINTENANCE 10 DATA CABLING 10 FIXTURE LINKING 10 GENERAL TROUBLESHOOTING 11 RETURN PROCEDURE 11 CLAI...

Страница 3: ...in types of information from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be...

Страница 4: ...ect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by u...

Страница 5: ...ing with or without DMX controller Built in automated programs via master slave or DMX with variable speed Built in sound activated programs via master slave or DMX Pulse effect with adjustable speed Additional Features Additional power output max 37 units Double bracket yoke doubles as floor stand Product Overview Microphone Sensitivity Adjustment Knob Power In Microphone DMX In DIP Switches Powe...

Страница 6: ...ted in front of the power input cable Please see the diagram below for further explanation The maximum quantity of fixtures that may be linked is 37 The power linking in this document is for the Chauvet North American version ONLY Therefore it is the customer s responsibility to check with the Dealer Distributor regarding power linking on the local version of the product Connections and availabili...

Страница 7: ...count the length of each power cable and mount the fixtures close enough to one another to accommodate for this When aiming the fixtures you may use the bracket adjustment knob Loosen the knob adjust to the desired angle and then tighten the knob by turning clockwise Do not use tools for this step as it may cause damage Safety cables must always be used ...

Страница 8: ... are two personalities for this fixture There is the standard 7 channel personality with strobe and color macros and then there is the basic 3 channel RGB personality Please see the DIP switch settings to access each of these personalities below Mode DIP switches 7 CH 11 12 Off 3 CH 11 On Master Slave Mode Sound Active Auto Mode Static Colors This mode allows a single unit to run a standalone prog...

Страница 9: ...atic Green 3 4 On Static Blue 5 6 On DMX Channel Values 7 CH Mode CHANNEL VALUE FUNCTION 1 000 255 Red Dimmer 0 100 2 000 255 Green Dimmer 0 100 3 000 255 Blue Dimmer 0 100 4 000 015 016 255 Color Macros overrides CH 1 3 No Function Color Macros 5 000 255 Speed CH 6 values 32 223 Slow Fast 000 015 016 255 Strobe RGB Macro only No Function Slow Fast 6 000 031 032 063 064 095 096 127 128 159 160 191...

Страница 10: ...nal optics at least every 20 days Clean the fixture at least every 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Data Cabling To link fixtures together you must obtain data cables You can purchase CHAUVET certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data gr...

Страница 11: ...lease contact CHAUVET Technical Support Return Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAUVET and request an RMA prior to shipping the fixture Be prepared to provide the model number serial nu...

Страница 12: ...ED 86 x 5 mm 44 red 21 green 21 blue 100 000 hrs PHOTO OPTIC Luminance 1 m 530 lux Beam Angle 19 Field Angle 36 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION LEDsplash 86B LEDSPLASH86B WARRANTY INFORMATION Warranty 2 year limited warranty Contact Us World Wide General Information CHAUVET Lighting 5200 NW 108th Avenue Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll f...