Chauvet LEDsplash 200B Скачать руководство пользователя страница 3

 

 

LED-PAR200B User Manual 

3

 

 

2010-03-09/15:03 

1.

 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

 

1 x LED-PAR200B 

 

1 x Warranty Card 

 

1 x Users Manual

Unpacking Instructions 

Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

To determine the power requirements for a particular product, see the label affixed to the back plate 

of the product or refer to the 

product’s specifications chart. A product’s listed current rating is its 

average current draw under normal conditions. All fixtures must be powered directly off a switched 

circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or 

dimmer channel is used solely for a 0% to 100% switch. Before applying power, check that the source 

voltage matches the 

product’s requirement. Check the product or device carefully to make sure that if 

a voltage selection switch exists that it is set to the correct line voltage you will use. 

 
Warning! 

All fixtures must be connected to circuits with a suitable Earth Ground. 

 

Safety Instructions 

 

Please keep this User Guide for future consultation. If 
you sell the unit to another user, be sure that they 
also receive this instruction booklet. 

 

Always make sure that you are connecting to the 
proper voltage and that the line voltage you are 
connecting to is not higher than that stated on decal 
or rear panel of the fixture. 

 

This product is intended for indoor use only! To 
prevent risk of fire or shock, do not expose fixture to 
rain or moisture. 

 

Make sure there are no flammable materials close to 
the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50 cm from adjacent surfaces. Be 
sure that no ventilation slots are blocked. 

 

Secure fixture to fastening device using a safety 
chain. 

 

Maximum ambient temperature is Ta: 40

° 

C. Do not 

operate fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using 
the unit immediately. Never try to repair the unit by 
yourself. Repairs carried out by unskilled people can 
lead to damage or malfunction. Please contact the 
nearest authorized technical assistance center. 

 

Don’t connect the device to a dimmer pack. 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on 
the cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

 Always disconnect from power source before 
servicing or replacing lamp or fuse and be sure to 
replace with same lamp source. 

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or attempt any 
repairs yourself. In the unlikely event your unit may require service, please contact 
CHAUVET®.

 

 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance. 

 

 

 

 

 

 

 

 

Содержание LEDsplash 200B

Страница 1: ...2 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2010 03 09 15 03 LEDsplash 200B LEDPAR200B Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Re...

Страница 2: ...CHANNEL VALUES 4 PRODUCT OVERVIEW 5 3 SETUP 6 POWER 6 MOUNTING 6 Orientation 6 Rigging 6 4 OPERATING INSTRUCTIONS 7 MASTER SLAVE MODE 7 DAISY CHAIN CONNECTION 7 DIP SWITCH OPTIONS 7 DMX CONTROL MODE 8...

Страница 3: ...for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line v...

Страница 4: ...st Color Change w fade 210 239 Sound 240 255 No Function CONTROL MODES OPTIONS Rows For a detailed view of DMX values turn to the Appendix section in this manual Control mode parameters are set by DMX...

Страница 5: ...on Safety attachment point Fuseholder DMX Master Slave Signal LED Indicator Standalone Auto Sound Selection Switch Bracket Adjustment Knob Power Input Hardwired cable Power LED Indicator Microphone Se...

Страница 6: ...resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requireme...

Страница 7: ...itivity knob on the back of the unit to make the unit more or less sensitive in Sound Active mode Turning the knob counterclockwise decreases the sensitivity turning the knob clockwise increases the s...

Страница 8: ...first time addressing a fixture using the DMX 512 control protocol than I suggest jumping to the Appendix Section and read the heading DMX Primer It contains very useful information that will help yo...

Страница 9: ...rial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no eff...

Страница 10: ...tion No Function Speed 000 255 120 149 Color Macro Color Macros See Table 1 1 No Function 150 179 R G B Chase RGB Chase pattern No Function Speed 000 255 180 209 Automatic Color change 210 239 Automat...

Страница 11: ...ipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packin...

Страница 12: ...332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 20...

Страница 13: ...FUSE Main 20 mm Glass 1 6 A Fast Blow SATELLITE OPERATION Run time 100 output full RGB 4 hrs Maximum Run Time auto program or single color Up to 8 hrs Connection 4 pin DIN connector CONTROL PROGRAMMI...

Отзывы: