Data Cabling 

To link fixtures together you must obtain data cables. You can purchase CHAUVET® certified DMX 
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own 
cable please use data-grade cables that can carry a high quality signal and are less prone to 
electromagnetic interference. 

DMX Data Cable 

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. 
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable must 
have the following characteristics: 

Type: 

shielded, 2-conductor twisted pair 

Maximum capacitance between conductors: 

30 pF/ft 

Maximum capacitance between conductor and shield: 

55 pF/ft 

Maximum resistance: 

20 ohms/1000 ft 

Nominal impedance: 

100 ~ 140 ohms 

Cable Connectors 

Cabling must have a male XLR connector on one end and a female XLR connector on the other end. 

Do not allow contact between the common and the fixture’s chassis ground. Grounding the 
common can cause a ground loop, and your fixture may perform erratically. Test cables with 
an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted 
to the shield or each other. 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures 
the data link can support.  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-
485 standard, no more than 32 fixtures should be connected on one data link. Connecting 
more than 32 fixtures on one serial data link without the use of a DMX optically-isolated 
splitter may result in deterioration of the digital DMX signal.  

Maximum recommended serial data link distance: 500 m (1640 ft)  

Maximum recommended number of fixtures on a serial data link: 32 

COMMON

 

DMX +

 

DMX

 -

 

INPUT

 

OUTPUT

 

1

 

3

 

2

 

1

 

3

 

2

 

1

 

3

 

2

 

120 ohm ¼ W 
resistor between 
pin 2 (DMX -) and 
pin 3 (DMX +) on 
the output of the 
last fixture 

To avoid signal transmission problems 
and interference, it is always advisable to 
connect a DMX signal terminator. 

DMX connector configuration 

Содержание LEDRain 56C

Страница 1: ... 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...NTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 CONFIGURING THE STARTING ADDRESS 8 DMX OPERATION 8 ACCESSING THE 2 PERSONALITIES 8 MASTER SLAVE MODE SOUND ACTIVE AUTO MODE STATIC COLORS 9 STROBE SPEED 9 STANDALONE OPERATION 10 Automatic 10 Sound Active 10 Static Colors 10 Fixture Linking 10 DMX CHANNEL VALUES 11 5 APPENDIX 12 DMX PRIMER 12 GENERAL MAINTENANCE 12 DATA CABLING 13 DMX Data...

Страница 3: ...ext CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This manual use...

Страница 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by un...

Страница 5: ...ing with or without DMX controller Built in automated programs via master slave or DMX with variable speed Built in sound activated programs via master slave or DMX Pulse effect with adjustable speed Additional Features Additional power output max 37 units Double bracket yoke doubles as floor stand Product Overview Power In Microphon e DIP Switches DMX Out Power Out Fuseholder DMX In Microphone Se...

Страница 6: ...ture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the Edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum quantity of fixtures that may be linked is 37 The power lin...

Страница 7: ...utine maintenance and control panel access Please see the following steps for installation Be sure to orient the gel frame release so that it is pointing up Please see the diagram below for a visual reference If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this ...

Страница 8: ...in 56C fixture uses seven or three DMX channels If this is your first time using DMX we recommend reading the DMX Primer section in the Appendix DMX Operation This is the operating mode which will allow for control with an external DMX controller You must set the starting address for this mode If this is your first time using DMX then it is recommended that you refer to the DMX Primer section in t...

Страница 9: ...he Master unit may be operated in Automatic Sound Active and Static Colors 2 Adjust the DIP switches to the Slave position on the slave units and they will react the same as the Master See below for DIP switch assignment Mode DIP switches Slave 2 11 Off 1 On Strobe Speed This fixture has a strobe speed adjustment which will decrease the maximum speed Please see the setting below for lowering the s...

Страница 10: ... fixture and the sensitivity may be adjusted using the audio adjustment knob Please see the chart below for further explanation Mode DIP switches Master Sound 10 On Static Colors This unit has separate DIP switches for each of the 3 colors red green and blue These are accessed via the DIP switches on the back of the fixture Each of the 3 colors may be mixed with different intensities Please see th...

Страница 11: ...nly No Function Slow Fast 6 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255 Mode RGB mode Pulse effect 0 100 using RGB faders Pulse effect 100 0 using RGB faders Pulse effect 100 0 100 using RGB faders Auto fade transition Auto snap transition 3 colors Auto snap transition 7 colors Sound triggering mode When CH 6 is set 032 223 CH 5 controls the speed 7 000 255 Dimmer Intensity RGB...

Страница 12: ...e with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up ...

Страница 13: ...your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number...

Страница 14: ... CHART Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not used Pin 4 Not used Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connect...

Страница 15: ...l wiring internal and or external Device does not power up No power Check for power on power outlet Loose power cord Check power cord Fixture is not responding to DMX Wrong DMX addressing Check Control Panel and unit addressing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faul...

Страница 16: ... UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of ...

Страница 17: ...er Consumption 120 VAC 60 Hz 8 W 0 2 A max 0 2 A inrush Power Consumption 230 VAC 50 Hz 5 W 0 1 A max 0 2 A inrush Power output 37 units max Fuse F 2 A 250 V LIGHT SOURCE LED 108 x 10 mm 36 red 36 green 36 blue 100 000 hrs PHOTO OPTIC Luminance 1 m 1 390 lux Beam Angle 20 Field Angle 32 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION LEDrain 56C LEDRAIN56C WARRANTY INFORMATION ...

Отзывы: