Appendix
TFX-UVLED User Manual
13
2006-10-11
/
12:19
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil
and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or
becomes dirty, clean the lamps with an alcohol wipe.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Binary & DMX DIP-switch Addressing
Each DIP-switch has an associated value. Adding the value of each switch in the ON position will
provide the final address. Determining which switches to toggle ON given a specific desired address
or value can be accomplished in the following manner. By subtracting the largest switch value
possible from the selected start address which does not cause a negative number.
Alternatively, using the “Binary Addressing Quick Reference Chart” in the Appendix section of this
manual, you can go directly to DIP-switch settings associated with all 512 values available.
E
XAMPLE
A
DDRESS
Address 10
Pin # 4
= 8
Pin # 2
= 2
Total
= 10
Address 24
Pin # 5
= 16
Pin # 4
= 8
Total =
24
Resolving address
using simple math.
Address 233
233 – (128) = 105, Turn ON Dip # 8
105 – (64) = 41, Turn ON Dip # 7
41 – (32) = 9, Turn ON Dip # 6
9 – (8) = 1, Turn ON Dip # 4
1 – (1) = 0, Turn ON Dip # 1
You will most likely use the first available
number which maybe number 1. This
number was selected for tutorial
purposes.
D
IP
S
WITCH
(DMX
V
ALUE
)
1
2
3
4
5
6
7
8
9
10
1
2
4
8
16
32
64
128
256
1 2 3 4 5 6 7 8 9 10
1
2
4
8
16
32
64
128
256
ON
1 2 3 4 5 6 7 8 9 10
1
2
4
8
16
32
64
128
256
ON