Chauvet LED PAR 64 Tri-B Скачать руководство пользователя страница 17

 
5. Appendix 

17 

6/21/2013 4:33 PM  

General Maintenance 

 

 

 

To maintain optimum performance and minimize wear, fixtures should be cleaned frequently.  

Usage and environment are contributing factors in determining frequency. As a general rule, 

fixtures should be cleaned at least twice a month. Dust build up reduces light output performance 

and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. 

Be sure to power off fixture before conducting maintenance. 

 

Unplug fixture from power.  

 

Use a vacuum or air compressor and a soft brush to remove dust collected on external 
vents. 

 

Clean all lenses when the fixture is cool with a mild solution of glass cleaner or 
Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue.  

 

Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens.  

 

Gently polish optical surfaces until they are free of haze and lint.  

The cleaning of external optical lenses and/or mirrors must be carried out periodically to optimize 

light output. Cleaning frequency depends on the environment in which the fixture operates. 

Damp, smoky or particularly dirty surroundings can cause greater accumulation of dirt on the 

unit’s optics. Clean with soft cloth using normal glass cleaning fluid. Clean the external optics at 

least every 20 days. Clean the fixture at least every 30/60 days. 

 

 

 

Always dry the parts carefully after cleaning them. 

 

 

 

Never spin a fan using compressed air. 

 
 

 

Returns Procedure 

 

 

 

Returned merchandise must be sent prepaid and in the original packing; call tags will not be 

issued. Package must be clearly labeled with a Return Merchandize Authorization Number (RMA 

#). Products returned without the RMA # will be refused. Call CHAUVET® and request an RMA # 

prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief 

description of the cause for the return. Be sure to pack fixture properly; any shipping damage 

resulting from inadequate packaging is the customer’s responsibility. As a suggestion, proper 

UPS packing or double-boxing is always a safe method to use. CHAUVET® reserves the right to 

use its own discretion to repair or replace product(s). 

 

 

 

If you are given an RMA #, please include the following information on a piece of paper 
inside the box:

 

 

 

1) 

Your name 

2) 

Your address 

3) 

Your phone number 

4) 

RMA # 

5) 

A brief description of the symptoms

 

 

 

Claims 

 

 

 

Damage incurred in shipping is the responsibility of the shipper; therefore, the damage must be 

reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify 

and submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any 

other claim for items such as missing component/part, damage not related to shipping, and 

concealed damage, must be made within seven (7) days of receiving merchandise. 

Содержание LED PAR 64 Tri-B

Страница 1: ...LED PAR 64 Tri B User Manual ...

Страница 2: ...rientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 CONFIGURING THE STARTING ADDRESS 8 CONTROL PANEL FUNCTIONS 8 MENU MAP 9 DMX Operation 10 Master Slave 10 Standalone 11 Automatic 11 Sound Active 11 Preset Colors 11 Custom Static Color Mixing 11 DMX CHANNEL VALUES 12 7 Channel Personality 12 3 Channel Personality 12 5 APPENDIX 13 GENERAL TROUBLESHOOTING 13 DMX PRIMER 14 FIXTURE LINKING DAISY CHAIN ...

Страница 3: ... regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This ...

Страница 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by un...

Страница 5: ...2013 4 33 PM 2 INTRODUCTION Product Overview DMX In Power In Microphone Sensitivity Adjustment Knob Microphone Bracket Adjustment Knob Power Out Fuseholder Control Panel LED Display DMX Out Hanging Bracket Secondary Bracket ...

Страница 6: ...or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 100 switch Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the Edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum quantity of LED PAR 64 TRI B fixtures that may be linked is...

Страница 7: ... orient the gel frame release so that it is pointing up Please see the diagram below for a visual reference If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this There is a secondary portion of the bracket which may be used primarily for floor standing positions ...

Страница 8: ...tions Access control panel functions using the four buttons located directly underneath the LED display on the included wired remote BUTTON FUNCTION MENU Used to scroll through the current operating mode as well as back out of the current menu option UP Used to select increasing advancement in the value DOWN Used to select decreasing advancement in the value ENTER Used to select a value and store ...

Страница 9: ...ound active programs Π6 3 Color sound active 3 ΧΗ δ001 δ512 Select 3 channel DMX mode RGB control 7 ΧΗ δ001 δ512 Select 7 channel DMX mode RGB macros run speed strobe automatic sound dimmer Χ Χ1 Red Select between 7 static colors The display will read C1 C7 The colors that each of these represent are indicated to the left Χ2 Green Χ3 Blue Χ4 Cyan Χ5 Magenta Χ6 Yellow Χ7 White Σ Σ001 Σ100 default r...

Страница 10: ...01 δ512 Master Slave This is the operating mode which will allow 1 fixture to act as the master and control all of the other slave fixtures You must set both the master and the slave s fixtures to the correct mode for this operation Master Settings 1 Connect the fixtures with DMX cables as shown in the Fixture Linking section 2 Use any one of the standalone modes for the master unit This includes ...

Страница 11: ...tatic color presets These are accessed via the control panel Please see the instructions below for further explanation 1 Press MENU until Χ appears on the LED screen 2 Press ENTER 3 Using UP and DOWN select the desired color preset Χ1 Χ7 4 Press ENTER to confirm settings Custom Static Color Mixing This fixture has the ability to accept custom static color settings These are accessed via the contro...

Страница 12: ... 6 Hz 18 Hz 6 000 ó 031 032 ó 063 064 ó 095 096 ó 127 128 ó 159 160 ó 191 192 ó 223 224 ó 255 Operating Mode RGB mode Pulse effect 0 100 using RGB faders Pulse effect 100 0 using RGB faders Pulse effect 100 0 100 using RGB faders Auto fade transition Auto snap transition 3 colors Auto snap transition 7 colors Sound triggering mode When CH 6 is set between 032 223 CH 5 controls the speed 7 000 ó 25...

Страница 13: ...ng Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier r...

Страница 14: ... pin 2 is Data Negative S and pin 3 is Data positive S Fixture Linking Daisy Chain You will need a daisy chain to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a daisy chain determines the number of fixtures the data link can sup...

Страница 15: ...o read the data on the channel indicated by the start address For example a fixture that uses six DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and note the start address selected for future reference If this is your first time addressing a fixture using the DMX co...

Страница 16: ...n 4 Not used Pin 5 Setting up a DMX Daisy Chain 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to connect from the output as stated above to ...

Страница 17: ...20 days Clean the fixture at least every 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAU...

Страница 18: ...or LED red green blue Quantity 18 Rating 3 W 350 mA x 3 50 000 hrs PHOTO OPTIC Lux 2 682 2 m Beam angle 22 Field angle 39 INDOOR OUTDOOR Rating For indoor use only THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR female socket Data output locking 3 pin XLR male socket Data pin configuration pin 1 shield pin 2 pin 3 Protocol DMX 512 USITT DMX Channels ...

Страница 19: ...0 NW 108 th Ave Sunrise FL 33351 voice 954 557 4455 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 577 4455 Press 4 fax 954 929 5560 Attention Service World Wide Web www chauvetlighting com ...

Отзывы: