background image

 
5. Appendix 

17 

10/27/2009 1:10 PM 

 

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing; call tags will not be issued. 

Package must be clearly labeled with a Return Merchandize Authorization Number (RMA #). 

Products returned without the RMA # will be refused. Call CHAUVET and request an RMA # prior to 

shipping the fixture. Be prepared to provide the model number, serial number and a brief description 

of the cause for the return. Be sure to pack fixture properly; any shipping damage resulting from 
inadequate packaging is the customer’s responsibility. As a suggestion, proper UPS packing or 

double-boxing is always a safe method to use.  

CHAUVET reserves the right to use its own discretion to repair or replace product(s). 

If you are given an RMA #, please include the following information on a piece of paper inside 
the box:

 

 

1) 

Your name 

2) 

Your address 

3) 

Your phone number 

4) 

The RMA # 

5) 

A brief description of the symptoms 

 

Claims 

Damage incurred in shipping is the responsibility of the shipper; therefore, the damage must be 

reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and 

submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any other claim 

for items such as missing component/part, damage not related to shipping, and concealed damage, 

must be made within seven (7) days of receiving merchandise. 

Содержание LED PAR 64-36B

Страница 1: ... 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com LED PAR 64 36B LED PAR 64 36C User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Autoswitching Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ... DMX Data Cable 10 Cable Connectors 10 3 Pin to 5 Pin Conversion Chart 11 Setting up a DMX Serial Data Link 11 4 OPERATING INSTRUCTIONS 12 DMX Operation 12 Accessing the 2 Personalities 12 Master Slave Mode Sound Active Auto Mode 80 12 Strobe Speed 12 STANDALONE OPERATION 13 Automatic 13 Sound Active 13 Static Colors 13 Fixture Linking 13 DMX CHANNEL VALUES 14 SETTING THE STARTING ADDRESS 15 GENER...

Страница 3: ...e regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This...

Страница 4: ...ect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by u...

Страница 5: ...nd RGB color mixing with or without DMX controller Built in automated programs via master slave or DMX with variable speed Built in sound activated programs via master slave or DMX Pulse effect with adjustable speed Additional Features Available in black or chrome High power 1 W 350 mA LEDs Additional power output 10 units max Double bracket yoke doubles as floor stand Includes gel frame Product O...

Страница 6: ...tric readings have been provided at 1 m 3 m and 5 m Below you will find a 3 dimensional drawing of the beam and field angles along with lux and beam diameter for the field and beam angles The lux measurements provided are maximum outputs at the distances stated ...

Страница 7: ...nput Hardwired Power Input Hardwired Microphone Audio Adjustment Knob Fuseholder Gel Frame Gel Frame Release Bracket Adjustment Knob Bracket Adjustment Knob Attachment Bolt not meant to be adjusted DMX Out Light Output Power Output Edison Safety attachment point Hanging mounting 13 mm hole DIP switches ...

Страница 8: ... 0 to 100 switch To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via...

Страница 9: ... The hole in each bracket is 13 mm in size When rigging consider routine maintenance and control panel access Please see the following steps for installation Be sure to orient the gel frame release so that it is pointing up Please see the diagram below for a visual reference If the power link out is intended to be used with multiple fixture take into account the length of each power cable and moun...

Страница 10: ... please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable must have the following characteristics Type shielded 2 conductor twisted pair ...

Страница 11: ...ART Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not used Pin 4 Not used Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector ...

Страница 12: ...see the DIP switch settings to access each of these personalities below Mode DIP switches 7 CH 11 12 Off 3 CH 11 On Master Slave Mode Sound Active Auto Mode Static Colors This mode allows a single unit to run a standalone program while 1 or more other units follow the same operation This requires the fixtures to be linked with DMX cables Please see the section on Fixture Linking 1 Turn switch to t...

Страница 13: ...e fixture and the sensitivity may be adjusted using the audio adjustment knob Please see the chart below for further explanation Mode DIP switches Master Sound 10 On Static Colors This unit has separate DIP switches for each of the 3 colors red green and blue These are accessed via the DIP switches on the back of the fixture Each of the 3 color may be mixed with different intensities Please see th...

Страница 14: ...only No Function Slow Fast 6 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255 Mode RGB mode Pulse effect 0 100 using RGB faders Pulse effect 100 0 using RGB faders Pulse effect 100 0 100 using RGB faders Auto fade transition Auto snap transition 3 colors Auto snap transition 7 colors Sound triggering mode When CH 6 is set 032 223 CH 5 controls the speed 7 000 255 Dimmer Intensity RG...

Страница 15: ...e electrical wiring internal and or external Device does not power up No power Check for power on Mains Loose power cord Check power cord Fixture is not responding to DMX Wrong DMX addressing Check Control Panel and unit addressing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections ...

Страница 16: ...e with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up ...

Страница 17: ...r UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of...

Страница 18: ...tion 120 VAC 60 Hz 44 W 0 6 A max 0 3 A inrush Power Consumption 230 VAC 50 Hz 48 W 0 3 A max 0 3 A inrush Power output 10 units max Fuse T 2 A 250 V LIGHT SOURCE LED 36 1 W 350 mA 50 000 hrs PHOTO OPTIC Luminance 1 m 5 800 lux Beam Angle 18 Field Angle 36 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION LED PAR 64 36B Black LEDPAR6436B LED PAR 64 36C Chrome LEDPAR6436C WARRANTY...