background image

Kinta™ X User Manual 

11 

7/23/2009 5:23 PM

 

DMX Quick Reference Chart 

DMX Address Quick Reference Chart 

DIP Switch Position 

DMX DIP 

SWITCH SET 

#9  0  0  0 

0=OFF 

#8  0  0  0 

1=ON 

#7  0  0  1 

X=OFF or ON  #6  0  1  0 

0

 

#1  #2  #3  #4  #5 

 

0  0  0  0  0 

 

  32  64  96  128  160  192  224  256  288  320  352  384  416  448  480 

1  0  0  0  0 

 

1  33  65  97  129  161  193  225  257  289  321  353  385  417  449  481 

0  1  0  0  0 

 

2  34  66  98  130  162  194  226  258  290  322  354  386  418  450  482 

1  1  0  0  0 

 

3  35  67  99  131  163  195  227  259  291  323  355  387  419  451  483 

0  0  1  0  0 

 

4  36  68  100  132  164  196  228  260  292  324  356  388  420  452  484 

1  0  1  0  0 

 

5  37  69  101  133  165  197  229  261  293  325  357  389  421  453  485 

0  1  1  0  0 

 

6  38  70  102  134  166  198  230  262  294  326  358  390  422  454  486 

1  1  1  0  0 

 

7  39  71  103  135  167  199  231  263  295  327  359  391  423  455  487 

0  0  0  1  0 

 

8  40  72  104  136  168  200  232  264  296  328  360  392  424  456  488 

1  0  0  1  0 

 

9  41  73  105  137  169  201  233  265  297  329  361  393  425  457  489 

0  1  0  1  0 

  10  42  74  106  138  170  202  234  266  298  330  362  394  426  458  490 

1  1  0  1  0 

  11  43  75  107  139  171  203  235  267  299  331  363  395  427  459  491 

0  0  1  1  0 

  12  44  76  108  140  172  204  236  268  300  332  364  396  428  460  492 

1  0  1  1  0 

  13  45  77  109  141  173  205  237  269  301  333  365  397  429  461  493 

0  1  1  1  0 

  14  46  78  110  142  174  206  238  270  302  334  366  398  430  462  494 

1  1  1  1  0 

  15  47  79  111  143  175  207  239  271  303  335  367  399  431  463  495 

0  0  0  0  1 

  16  48  80  112  144  176  208  240  272  304  336  368  400  432  464  496 

1  0  0  0  1 

  17  49  81  113  145  177  209  241  273  305  337  369  401  433  465  497 

0  1  0  0  1 

  18  50  82  114  146  178  210  242  274  306  338  370  402  434  466  498 

1  1  0  0  1 

  19  51  83  115  147  179  211  243  275  307  339  371  403  435  467  499 

0  0  1  0  1 

  20  52  84  116  148  180  212  244  276  308  340  372  404  436  468  500 

1  0  1  0  1 

  21  53  85  117  149  181  213  245  277  309  341  373  405  437  469  501 

0  1  1  0  1 

 

22  54  86  118  150  182  214  246  278  310  342  374  406  438  470  502 

1  1  1  0  1 

23  55  87  119  151  183  215  247  279  311  343  375  407  439  471  503 

0  0  0  1  1 

24  56  88  120  152  184  216  248  280  312  344  376  408  440  472  504 

1  0  0  1  1 

25  57  89  121  153  185  217  249  281  313  345  377  409  441  473  505 

0  1  0  1  1 

26  58  90  122  154  186  218  250  282  314  346  378  410  442  474  506 

1  1  0  1  1 

27  59  91  123  155  187  219  251  283  315  347  379  411  443  475  507 

0  0  1  1  1 

28  60  92  124  156  188  220  252  284  316  348  380  412  444  476  508 

1  0  1  1  1 

29  61  93  125  157  189  221  253  285  317  349  381  413  445  477  509 

0  1  1  1  1 

30  62  94  126  158  190  222  254  286  318  350  382  414  446  478  510 

1  1  1  1  1 

  31  63  95  127  159  191  223  255  287  319  351  383  415  447  479  511 

Dip Switch Position                                                   DMX  Address 

Содержание Kinta X

Страница 1: ...0 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com Kinta X User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Autoswitching Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ... Pin to 5 Pin Conversion Chart 7 SETTING UP A DMX SERIAL DATA LINK 7 MOUNTING 8 Orientation 8 Rigging 8 5 OPERATING INSTRUCTIONS 9 OPERATION 9 Stand Alone Mode Sound Active Auto Mode 9 DMX Mode 9 DMX CHANNEL VALUES 9 Setting the Starting Address 10 DMX Quick Reference Chart 11 6 APPENDIX 12 DMX PRIMER 12 GENERAL MAINTENANCE 13 RETURNS PROCEDURE 13 CLAIMS 13 GENERAL TROUBLESHOOTING 14 CONTACT US 15...

Страница 3: ...ecal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disco...

Страница 4: ...ted programs via standalone or DMX Built in sound activated programs via standalone Additional Features High power 3 W 730 mA LEDs Linkable with LED Mushroom and Double Derby X Mount multiple units together with adjustable optional bracket XBRACKET Additional power output max 37 units DMX Channel Summary CHANNEL FUNCTION 1 Control Operating Mode 2 Motor rotation ...

Страница 5: ...Kinta X User Manual 5 7 23 2009 5 23 PM Product Overview Sound sensitivity adjustment Dipswitches DMX Out DMX In Power link out Power In Hanging mounting bracket Bracket adjustment knob ...

Страница 6: ...serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 m 1640 ft Maximum recommended number of fixtures on a serial data link 32 Data Cabling To link fixtures together you must obtain data cables You can purchase CHAUVET certified DMX cables directly from a dealer distributor or c...

Страница 7: ... 5 PIN CONVERSION CHART Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not Used Pin 4 Not Used Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a fem...

Страница 8: ...e of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables must always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Do n...

Страница 9: ...he knob counterclockwise decreases the sensitivity turning the knob clockwise increases the sensitivity DMX Mode This mode allows the unit to be controlled by any universal DMX controller If you are unfamiliar with DMX please read the DMX Primer 1 Set DIP switches position to DMX mode Mode DIP switches DMX 10 On 2 Use DIP switches 1 9 to set the DMX address DMX Channel Values CHANNEL VALUE FUNCTIO...

Страница 10: ...y doing the following 1 Determine the largest value switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the...

Страница 11: ...64 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146...

Страница 12: ...control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next ...

Страница 13: ...uid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET an...

Страница 14: ...fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Moves slow Check 220 110v switch...

Страница 15: ...7 mm Height 10 4 in 264 mm Weight 6 lbs 2 7 kg POWER Autoswitching 100 240 VAC 50 60 Hz Fuse 2 A 250 V Power Consumption 24 W 0 2 A max 120 V Inrush Current 0 5 A 120 V Power Output 37 units max LIGHT SOURCE LED 3 x 3 W 730 mA 1 Red 1 Green 1 Blue 50 000 hrs PHOTO OPTIC Coverage Angle 135 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Da...

Отзывы: