background image

 

DMX-680 User Manual  

 

2006-10-10

/

18:04 

1. Before You Begin 

Unpacking Instructions 

Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. 

Save the carton and all packing materials

. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

Note:

  

If you should require sending any items back to CHAUVET, call CHAUVET for a 

(RMA) Return Merchandise Authorization number. The factory will not allow any shipments without 
an RMA.  

Y o u r   s h i p m e n t   i n c l u d e s   t h e   f o l l o w i n g :  

1 x Intimidator Spot™ DMX-680 
1 x ELC 24v 250w lamp 
1 x Power cable 
2 x brackets 
Warranty Card 
Users Manual 

Contact Us 

W o r l d   W i d e  

General Information 

Chauvet Lighting 

3000 North 29

th

 Court 

Hollywood, FL 33020 

voice: 954.929.1115 

fax: 954.929.5560 

toll free:  800.762.1084 

Technical Support 

Chauvet Lighting 

3000 North 29

th

 Court 

Hollywood, FL 33020 

voice: 954.929.1115

 (Press 4)

 

fax: 954.929.5560

 (Attention: Service)

 

World Wide Web 

www.chauvetlighting.com 

Содержание Intimidator Spot DMX-680

Страница 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 10 10 18 04 DMX 680 USER MANUAL ...

Страница 2: ...INKING 8 Data Cabling 8 DMX Data Cable 9 Cable Connectors 9 3 Pin to 5 Pin Conversion Chart 9 SETTING UP A DMX SERIAL DATA LINK 10 STANDALONE MASTER SLAVE FIXTURE LINKING 10 4 OPERATING INSTRUCTIONS 11 NAVIGATING THE CONTROL PANEL 11 CONTROL OPERATING MODE N O D E 11 DMX Mode N dN 11 Stand Alone Master Slave N So N SL N Au 12 DMX ADDRESSING A D D R 12 USER CONFIGURATIONS 13 Individual Pan Tilt Rev...

Страница 3: ...at the fixture be returned in the original factory box and packing Note If you should require sending any items back to CHAUVET call CHAUVET for a RMA Return Merchandise Authorization number The factory will not allow any shipments without an RMA Your shipment includes the following 1 x Intimidator Spot DMX 680 1 x ELC 24v 250w lamp 1 x Power cable 2 x brackets Warranty Card Users Manual Contact U...

Страница 4: ...Using the wrong type of lamp in this product VOIDS the warranty Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Mainta...

Страница 5: ... Blackout reset sound activation and built in automatic programs via DMX Built in automated programs via master slave or DMX Built in sound activated programs via master slave or DMX Additional Features Dual hanging brackets with turn fasteners Compact and lightweight LED display menu with invert Pan tilt invert option Micro stepping motors Thermal switch fan cooled DMX Channel Summary Channel Fun...

Страница 6: ... 2006 10 10 18 04 DMX Output Power cable DMX Input Fuse Compartment Clamp brackets with turn locks Rubber feet Green LED DMX Signal Indicator Focusing lens gun Carrying Handles Projector Head LED Control Panel Yoke Arm Product Overview ...

Страница 7: ...to circuits with a suitable Earth Ground Power Cable Configuration CABLE Pin International Screw Color BROWN Live L Yellow or Brass BLUE Neutral N Silver YELLOW GREEN Earth EG Ground Green Lamp Installation You will need to install a lamp prior to the initial operation of the fixture Warning When replacing the lamp please wait 15 minutes after powering down to allow the unit to cool down Always di...

Страница 8: ...ad of looping through a hanging yoke arm Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX 512 controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support The DMX...

Страница 9: ...mon can cause a ground loop and your fixture to perform erratically Test cables with OHM meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other 3 Pin to 5 Pin Conversion Chart Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter CHAUVET Model No DMX5M The chart below details a proper...

Страница 10: ...e to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to connect from the output as stated above to the input of the following fixture and so on CHAUVET Certified DMX Data Cables Order Code Description D...

Страница 11: ...nu options Press the Enter button to access the menu function currently displayed or to enable a menu option To return to the previous option or menu without changing the value press the Fun button Control Operating Mode N o d E The DMX 680 has four control or operating modes that must be defined in each fixture in order to work correctly under stand alone master slave or manual DMX control Please...

Страница 12: ...ode enables the use of a universal DMX controller device Each fixture requires a start address from 1 to 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 6 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Ch...

Страница 13: ...ilt of all fixtures at the same time you will notice that the fixtures whose orientation is different from the others will most likely move opposite of the rest You can apply a pan and tilt Invert by following the settings in the table below MENU LEVEL 1 OPTION LEVEL 2 DESCRIPTION Standard Pan Movement Normal left to right Reverse Pan Movement Inverted movement from right to left Standard Tilt Mov...

Страница 14: ...ting of the Tilt movement Pan Testing of the Pan movement Color Tests the color wheel Gobo Tests the gobo wheel Shutter Tests the shutter Reverse the segment display d S P L You can rotate the display 180 so that it becomes easier to read when the fixture is positioned upside down MENU OPTION DESCRIPTION Standard Standard display orientation Reverse Rotated display orientation Fixture reset r E S ...

Страница 15: ...sitive S CHAUVET carries 3 pin XLR DMX compliant cables DMX 10 33 DMX 4 5 15 and DMX 1 5 5 Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be p...

Страница 16: ...Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days DMX Channel Values CHANNEL VALUE FUNCTION 1 000 Ù 127 128 Ù 179 180 Ù 223 224 Ù 250 251 Ù 255 Control Operating Mode DMX Mode Stand alone automatic Stand alone sound active Lamp turn on after 10 seconds Lamp shut...

Страница 17: ...2 and on Stand Alone mode running at an automatic preset speed Standard pan movement Reverse pan movement Standard tilt movement Reverse tilt movement Combined control of pan tilt standard default Combined control of pan tilt reversed settings Tests all motors in the fixture Provides testing of the pan movement Provides testing of the tilt movement Provides testing of the color wheel Provides test...

Страница 18: ...m Angle 11 Pan 510 Tilt 260 Illuminance 2 330fc or 25 070lux 1 meter FUSE Main 20mm Glass 7A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 7 ORDERING INFORMATION Intimidator Spot DMX 680 Technical Support Address Service Dept 3000 N 29th Ct Holly...

Отзывы: