Chauvet Hurricane Haze 3D Скачать руководство пользователя страница 4

 
 
 
 

Page 4 of 16 

Hurricane™ Haze 3D User Manual Rev. 1 

 

Product at a 

Glance 

Use on Dimmer 

x

 

Auto Programs 

x

 

Outdoor Use 

x

 

Auto-ranging Power Supply 

x

 

Sound-Activated 

x

 

Replaceable Fuse 

P

 

DMX 

P

 

User-Serviceable 

x

 

Master/Slave 

x

 

 

 

Safety Notes  

 

Please read the following Safety Notes carefully before working with the 

product. The Notes include important safety information about installation, 
usage, and maintenance. 

 

  Not intended for permanent installations. 

  Always connect the product to a grounded circuit to avoid the risk of electrocution. 

  Always disconnect this product from the power source before cleaning it or 

replacing the fuse. 

  Make sure the power cord is not crimped or damaged. 

  Never disconnect the power cord by pulling or tugging on the cord. 

  Do not touch the output nozzle on this product. It is very hot during operation and 

it may remain hot for several hours after turning the unit off. 

  If mounting this product overhead, always secure it to a fastening device using a 

safety cable. 

  Do not mount this product on a flammable surface (e.g., wood, linoleum, carton, 

plastic, or carpet). 

  Do not drink the haze fluid. If you do, call your local emergency service  

(911 in the US) for help. 

  Do not add perfume, alcohol, gasoline, or any other flammables to the haze fluid. 

 

  Always make sure that the voltage of the outlet to which you are connecting the 

product is within the range stated in the decal or rear panel of the product. 

  Keep this User Manual for future consultation. If you sell this product to another 

user, be sure that they also receive this document. 

  This product is for indoor use only! To prevent risk of fire or shock, do not expose 

this product to rain or moisture. 

  Make sure there are no flammable materials close to the unit while operating 

  Always install this product in a location with adequate ventilation, at least  

20 in (50 cm) from adjacent surfaces.  

 

  Be sure that no ventilation slots on the unit’s housing are blocked. 

  Make sure to replace the fuse with another of the same type and rating. 

  The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate this 

product at higher temperatures. 

  In the event of a serious operating problem, stop using the unit immediately. 

  Never try to repair this product. Repairs carried out by unskilled people can lead 

to damage or malfunction. Please contact the nearest authorized technical 
assistance center. 

  Never connect this product to a dimmer or rheostat. 

  Depending on the amount of haze generated, all haze machines may set off 

smoke detectors. 

  In certain environment, haze fluid-based machines may leave a slippery residue 

on floors and surfaces. 

  Do not use for space heating purposes. 

  Use only CHAUVET® DJ water-based haze fluid. 

  Drain the tank before transporting the product. 

  To eliminate unnecessary wear and improve its lifespan, during periods of non-

use completely disconnect the product from power via breaker or by unplugging it. 

 

FCQ (Fog Cleaner Quart) was  specifically developed by Chauvet  to clean your 
Hurricane™  Haze 3D.  Make sure you use FCQ regularly to  increase the life of 
your product. 

Содержание Hurricane Haze 3D

Страница 1: ...User Manual ...

Страница 2: ...oduct Dimensions 6 3 Setup 7 AC Power 7 Fuse Replacement 7 Mounting 8 Orientation 8 Rigging 8 4 Operation 10 Control Panel Operation 10 Fluid Tank Indicator LEDs 10 Menu Map 10 HC T Wired Timer Remote Operation 11 Configuration Standalone Mode 12 Manual Mode 12 Configuration DMX 12 Starting Address 12 DMX Channel Assignments and Values 12 2 CH 12 5 Technical Information 13 General Maintenance 13 S...

Страница 3: ...on Meaning Menu A key to be pressed on the product s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status Menu Settings A sequence of menu options to be followed ON A value to be entered or selected Symbols Convention Meaning Critical installation configuration or ...

Страница 4: ...this User Manual for future consultation If you sell this product to another user be sure that they also receive this document This product is for indoor use only To prevent risk of fire or shock do not expose this product to rain or moisture Make sure there are no flammable materials close to the unit while operating Always install this product in a location with adequate ventilation at least 20 ...

Страница 5: ...on Product Overview Wired Remote Controller Socket Power In Power Switch Fluid Level Indicator Access Door and Storage Compartment for the HC T DMX In Out Fuse Holder Internal Fluid Tank Indicator Lights Digital Control Panel Display and Menu Buttons Safety Loop ...

Страница 6: ...Page 6 of 16 Hurricane Haze 3D User Manual Rev 1 Product Dimensions 15 in 380 mm 13 4 in 340 mm 12 9 in 328 mm ...

Страница 7: ...round to avoid the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement Disconnect this product from the power outlet before replacing the fuse 1 Disconnect the product from power 2 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 3...

Страница 8: ...gging point whether an elevated platform or a truss When rigging this product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When mounting this product overhead always use a safety cable Never mount directly above people as condensation may drip and fluid may be hot Before deciding on a location for thi...

Страница 9: ...ricane Haze 3D User Manual Rev 1 Page 9 of 16 Mounting Diagram Bracket Adjustment Knob 2 Mounting Bracket Mounting Clamp such as CLP 15N clamp from Chauvet Safety Cable Rubber Feet for floor mounting 15 15 ...

Страница 10: ... level Examples If using the digital control panel and afterwards you connect a DMX controller to the product then the DMX controller will take priority control If using the remote controller and the digital control panel is used next then the digital control panel will take priority control Fluid Tank Indicator LEDs Indicator LEDs show the status of the fill tank as follows Red the fluid tank is ...

Страница 11: ...and OUTPUT adjustment knobs to the desired positions INTERVAL knob sets the amount of time in between bursts of haze DURATION knob sets the length of time that the haze machine will run during the burst OUTPUT knob adjusts the haze output 5 Press the CONTINUOUS latching button and the haze machine outputs haze until the button is pressed again The Manual Power LED Indicator above the button will l...

Страница 12: ...X controller 1 Connect this product to a suitable power outlet 2 Turn this product on 3 Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket of this product Starting Address The Hurricane Haze 3D has one DMX personality a 2 channel mode for basic control The Hurricane Haze 3D uses up to two channels in its 2 channel DMX mode which defines the highest configurable a...

Страница 13: ...mp to run dry 6 Refill with haze fluid to continue using the hazer Run the machine briefly to clear any remaining cleaning solution from the pump and heater Note Do not operate the machine without fluid at any time Fog Cleaner Quart FCQ was specifically developed by Chauvet to clean your Hurricane Haze 3D Make sure you use FCQ regularly to increase the life of your product Storage Before storing t...

Страница 14: ...l cables are not DMX compatible Replace non DMX cables with true DMX cables Interference with AC or radio signals Keep DMX cables away from AC wires or radio equipment DMX cable too long Use a shorter DMX cable or install an optically coupled DMX amplifier right before the product with intermittent problems Terminator not connected Install a terminator False Sensor Reading Priming Air bubbles in f...

Страница 15: ...rating current 11 A 6 2 A Fuse size F 13 A 250 V F 7 A 250 V Power I O US Canada UK Worldwide Power input connector IEC IEC Power cord plug Edison Local plug Operation Heat up Time Tank Capacity Fluid Consumption 4 min 0 7 gal 2 5 l 14 ml min Misc Output 1 700 cfm Approved Fluids CHAUVET DJ Haze Fluid Gallon High Performance Haze Fluid HFG Premium Haze Fluid PHF Thermal Maximum External Temp Cooli...

Страница 16: ...duct clearly write the following information on a piece of paper and place it inside the box Your name Your address Your phone number RMA number A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be your responsibility FedEx packing or double boxing is recommended Chauvet reserves the right to use its own discretion ...

Отзывы: