background image

 

 

Appendix 

CH-160A User Manual 

2005-12-08/17:20 

Technical Specifications 

 
WEIGHT & DIMENSIONS 
Length........................................................................................................................... 279 mm (11 in) 
Width............................................................................................................................. 279 mm (11 in) 
Height ........................................................................................................................ 120 mm (4.75 in) 
Weight............................................................................................................................. 5 Kgs (11 lbs) 
Shipping weight............................................................................................................... 5 Kgs (11 lbs) 
 
POWER 
Power............................................................................................................115V 60Hz or 230V 50Hz 
Current draw .......................................................................................................(peak 190W @ 120V) 
 
LAMPS 
BRL x (2)................................................................................................................................ 50W 12V 
 
THERMAL 
Maximum ambient temperature ......................................................................................... 40

° (104° F)

 

 
FUSE 
Main ................................................................................................... 20mm Glass 3A 250V Fast Blow 
PCB ................................................................................................... 20mm Glass 3A 250V Fast Blow 
 
ORDERING INFORMATION 
Duo Moons

. ........................................................................................................................ CH-160A 

Fuse 3A ........................................................................................................................ P170FUSE003 

Technical Support 

Address: 

Service Dept. 

 

3000 N 29

th

 Ct, Hollywood, FL 33020 (U.S.A.) 

Support (Email):  

[email protected]

 

Telephone: 

(954) 929-1115 - (Press 4) 

Fax: 

(954) 929-5560 - (Attention: Service) 

Website: 

http://www.chauvetlighting.com 

 
 

Содержание Duo Moons CH-160A

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 12 08 17 20 CH 160A Duo Moons USER MANUAL ...

Страница 2: ... INSTRUCTIONS 3 AC POWER 3 SAFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 MOUNTING 5 Orientation 5 Rigging 5 OPERATING INSTRUCTIONS 6 APPENDIX 7 GENERAL MAINTENANCE 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 8 TECHNICAL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 ...

Страница 3: ...er user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable mat...

Страница 4: ... Independent flashing rotating static modes Additional optional dishes sold separately Product Overview Hanging Bracket Microphone NOTICE This is not a power switch Mode Switch ON Sound Activated Dishes will rotate back and forth to the sound OFF Auto Programs Dishes will rotate back and forth automatically and not by sound Fuse holder Lamp cover plate Plate removed and lamps exposed ...

Страница 5: ...ng the lamp remove old lamp first 3 Reach in and using a cloth or napkin hold the bulb and pull out of the lamp socket located inside the reflector 4 Replace with a new lamp 5 Replace lamp cover align the screw holes and fasten the thumbscrews Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING It is important never to obstruct t...

Страница 6: ... of a relay system for remote switching or to go with DMX control use the latest in DMX compatible Dimmer Relay Pack all available from CHAUVET A relay system will allow you to remotely trigger the Duo Moons and any other non dimmable effect light from a switch panel Make sure to use a cable of at least 25 feet to provide ample distance between the control panel and the switch pack for most mobile...

Страница 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Страница 8: ...ely in order to measure correctly check to see if perhaps it is stuck Fogger or Snow output has dropped Clean with distilled water and vinegar Replace hose Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick s...

Страница 9: ...ent draw peak 190W 120V LAMPS BRL x 2 50W 12V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3A 250V Fast Blow PCB 20mm Glass 3A 250V Fast Blow ORDERING INFORMATION Duo Moons CH 160A Fuse 3A P170FUSE003 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone 954 929 1115 Press 4 Fax 954 929 5560 Attention Se...

Отзывы: