Chauvet DMX-250C Скачать руководство пользователя страница 7

 

 

Setup 

DMX-250C User Manual 

Revision: 5/17/2005 10:49 PM

 

Figure 2 - Hanging Clamp 

Note! 
Clamp is sold separately. 

Rotate lens gun 
clockwise and 
counter-clockwise 
to achieve desired 
focus. 

IN 

OUT 

 The fuse is located 
inside this 
compartment. 
Remove using a flat 
head screwdriver. 

Mounting 

O RI E NT AT I O N 

This fixture may be mounted in any position provided there is adequate room for ventilation.  

RI G G I NG   

It is important never to obstruct the fan or vents pathway. Mount the 

fixture using, a suitable 

C

 or 

O

 type clamp. Adjust the angle of the 

fixture by loosening both knobs and tilting the fixture. After finding the 

desired position, retighten both knobs. 

 

When selecting installation location, take into consideration lamp 
replacement access and routine maintenance.  

 

Safety cables should always be used.  

 

Never mount in places where the fixture will be exposed to rain, high 
humidity, extreme temperature changes or restricted ventilation. 

 

Manual Focusing 

To adjust the focus, please follow the instructions below. 

1) 

If operating in stand alone mode, turn the music 
down so that the unit temporarily stops any activity, 
other wise turn the lamp on using Channel 4.  

2) 

Rotate the lens gun either clockwise or counter-
clockwise until the spot is defined by a hard edge.  

Fuse Replacement 

With a flat head screwdriver wedge the fuse 

holder out of its housing. Remove the damaged 

fuse from its holder and replace with exact 

same type fuse. Insert the fuse holder back in 

its place and reconnect power.  

 

 

 

Disconnect the power cord before replacing a fuse and 

always replace with the same type fuse. 

 

 

Содержание DMX-250C

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com DMX 250C Omega 250C USER MANUAL...

Страница 2: ...6 Lamp installation 6 POWER 6 MOUNTING 7 Orientation 7 Rigging 7 MANUAL FOCUSING 7 FUSE REPLACEMENT 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 M...

Страница 3: ...ctions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the...

Страница 4: ...only 15 lbs any mobile DJ can truly appreciate its portability and extreme power Ideal show conditions would include 4 or more Omega 250Cs and an atmospheric effect device such as a fogger or hazer Fe...

Страница 5: ...Hook Attach safety cable to this hook Audio Sensitivity POT Adjust audio sensitivity to improve fixture response Integrated Mic Dipswitches Provided for DMX channel addressing Voltage Selector Choose...

Страница 6: ...lamp to the lamp socket and follow the same procedure as above to insert lamp into lamp cage 5 Replace top cover and screws 6 No lamp alignment is necessary for this fixture Power Your product is equi...

Страница 7: ...ake into consideration lamp replacement access and routine maintenance Safety cables should always be used Never mount in places where the fixture will be exposed to rain high humidity extreme tempera...

Страница 8: ...e programs are constructed based on the control of four units Connecting the Omega 250Cs for Master Slave operation does not require any menu or setting selections Simply connect each Omega 250C in a...

Страница 9: ...e independently SETTING THE STARTING ADDRESS This DMX mode enables the use of a universal DMX controller device Each fixture requires a start address from 1 to 511 A fixture requiring one or more chan...

Страница 10: ...E STARTING ADDRESS THE CHANNEL ADDRESSES WERE SELECTED AT RANDOM IT IS RECOMMENDED TO SEQUENCE YOUR FIXTURES FOLLOWING A NUMERICAL ORDER Address 10 Pin 4 8 Pin 2 2 Total 10 Address 24 Pin 5 16 Pin 4 8...

Страница 11: ...of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an orde...

Страница 12: ...9 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 255 Color Closed White Open Magenta Amber Cyan Dark Green Pink Blue Red Yellow Green Dark Red Dark Pink UV Purple Light Blue Orang...

Страница 13: ...nds on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass c...

Страница 14: ...ust sound sensitivity knob Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps requir...

Страница 15: ...115V 60 Hz or 230V 50 Hz AC input 3 prong IEC 60320 C14 male socket LAMPS ELC3 300 hr 250W 24V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3 15A Fast Blow CONTROL PROGRAMMING Dat...

Отзывы: