background image

 

CH-258 User Manual 

2006-05-04/23:59 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

 

1 x Cyborg

 (CH-258) 

 

Power cord with plug 

 

2 x 64514 300w lamp 

 

Warranty Card & Manual

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 

the fixture or refer to the fixture

s specifications chart. A fixture

s listed current rating is its average 

current draw under normal conditions. All fixtures must be powered directly off a switched circuit and 

cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer 

channel is used solely for a 0% to 100% switch. Before applying power to a 

fixture, check that the source voltage matches the fixture

s requirement. 

Check the fixture or device carefully to make sure that if a voltage selection 

switch exists that it is set to the correct line voltage you will use. 

Warning! 

Verify that the power select switch on your unit matches the 
line voltage applied. All fixtures must be connected to circuits 
with a suitable Earth Ground.  

 

Safety Instructions 

 

Please keep this User Guide for future consultation. If you 
sell the unit to another user, be sure that they also receive 
this instruction booklet. 

 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on decal or rear panel of the 
fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50cm from adjacent surfaces. Be sure 
that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or 
replacing lamp or fuse and be sure to replace with same 
lamp source. 

 

Secure fixture to fastening device using a safety chain. 
Never carry the fixture solely by its head. Use its carrying 
handles. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate 

fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using the 
unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to 
damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the 
same type spare parts. 

 

Don

t connect the device to a dimmer pack.

 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the 
cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET. 

AC Voltage Switch 

 

Not all fixtures have a voltage 
select switch. Please be sure to 
connect to the proper voltage. 

 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance? 

 

 

Содержание Cyborg CH-258

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 05 04 23 59 CH 258 Cyborg USER MANUAL ...

Страница 2: ...AFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 MOUNTING 5 Orientation 5 Rigging 5 OPERATING INSTRUCTIONS 6 Duty Cycle 6 APPENDIX 7 GENERAL MAINTENANCE 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 8 LAMP IN SERIES WIRING FOR 230V OPERATION 9 TECHNICAL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 ...

Страница 3: ...o another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flamma...

Страница 4: ...ams Built in microphone and sound sensitivity knob Beams rotate and criss cross to the music Wide area light coverage Fan cooled Product Overview Voltage switch Fixture top cover removed for lamp access Bottom view Top View Hanging Bracket Fuse and power connector Sound sensitivity knob Microphone ...

Страница 5: ...e S1 screws that surround the fixture s top cover 2 If replacing the lamp remove old lamp first 3 Reach in and using a cloth or napkin hold the bulb and pull out of the lamp socket located inside the reflector 4 Replace with a new lamp 5 Replace fixture cover align the screw holes and fasten the screws 6 No lamp alignment is necessary for this fixture since the lamp is already optimized inside the...

Страница 6: ...able from CHAUVET A relay system will allow you to remotely trigger the Cyborg and any other non dimmable effect light from a switch panel Make sure to use a cable of at least 25 feet to provide ample distance between the control panel and the switch pack for most mobile lighting applications If you would prefer to control it directly from your DMX lighting console then we suggest a DMX compatible...

Страница 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Страница 8: ...ly in order to measure correctly check to see if perhaps it is stuck Fogger or Snow output has dropped Clean with distilled water and vinegar Replace hose Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick st...

Страница 9: ... 230V counter parts Technical Specifications WEIGHT DIMENSIONS Length 406 mm 16 in Width 279 mm 11 in Height 279 mm 11 in Weight 5 Kgs 11 lbs Shipping weight 6 8 Kgs 15 lbs POWER Switch selectable power 115V 60Hz or 230V 50Hz AC input 3 prong IEC 60320 C14 DUTY CYCLE 1 Fixture ON not to exceed 15 minutes 2 Fixture OFF cool down for 15 minutes LAMPS 115V 64514 x 2 300W 120V 230V 64514 x 2 In Series...

Отзывы: