Cubix™ 2.0 QRG
EN
4
Menu Options
Main Level
Programming Levels
Description
DMX Address
512
d__1-d512
Sets the DMX starting address
Auto Programs
AUTO
Sets Auto Program
Auto Program Speed
S--
S__1-S100
Selects Auto Program speed (slow to fast)
Sound-Active Mode
SNd
Sets Sound-Active mode
DMX Linking
The Cubix™ 2.0 can work with a DMX controller when linked by DMX serial
connections. Instructions for connecting and configuring this product for
DMX operation are in the User Manual. If you are not familiar with DMX,
download the DMX Primer from
www.chauvetlighting.com
.
Starting Address
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is
506
.
Master/Slave
Connection
The Cubix™ 2.0 uses the DMX data connection for its Master/Slave mode.
Instructions for connecting and configuring this product for Master/Slave
operation are in the User Manual.
DMX Values
7-CH
Channel Function
Value
Percent/Setting
1
Colors
000
004 No function
Side Lenses
005
028 Red
029
056 Green
057
084 Blue
085
112 Cyan
113
140 Purple
141
168 Yellow
169
197 White
198
224 3-Color switching
225
255 7-Color switching
2
Strobe
000
004 No function
005
255 0~30 Hz
3
Motor Rotation
000
127 Rotation with indexing
128
255
Back and forth with
increasing distance
4
Auto Programs
000
014 Blackout
Middle Lens
015
255 Auto Programs
5
Auto Program
Speed
000
015 No function
016
255
0~100% (when Ch. 4 is
015~255)
6
Strobe
000
015 No function
016
255 0~30 Hz
7
Auto Programs
(All Lenses)
000
009 No function
All Lenses
010
250 Auto programs (slow~fast)
251
255 Sound active
Содержание Cubix 2.0