EN
COLORrail™ IRC IP QRG
5
DMX Linking
The COLORrail™ IRC IP can work with a DMX controller when linked by
DMX serial connections. Instructions for connecting and configuring this
product for DMX operation are in the User Manual. If you are not familiar
with DMX, download the DMX Primer from
www.chauvetlighting.com
.
Starting Address
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is
487
.
Master/Slave
Connection
The COLORrail™ IRC IP uses the DMX data connection for its
Master/Slave mode. Instructions for connecting and configuring this product
for Master/Slave operation are in the User Manual.
DMX Values
2-CH
Channel Function
Value
Percent/Setting
1
Color Macros
000
008 No function
009
017 Red
018
026 Yellow
027
035 Green
036
044 Cyan
045
053 Blue
054
062
Magenta
063
071 White
072
255 Auto Programs
2
Auto Program
Speed
000
255
Program speed slow to fast (when CH.1 is
from 072–255)
3-CH
Channel Function
Value
Percent/Setting
1
Red
000
255 0–100%
2
Green
000
255 0–100%
3
Blue
000
255 0–100%
4-CH
Channel Function
Value
Percent/Setting
1
Master Dimmer
000
255 0–100%
2
Red
000
255 0–100%
3
Green
000
255 0–100%
4
Blue
000
255 0–100%
Содержание COLORrail IRC IP
Страница 1: ...Quick Reference Guide ...