General Troubleshooting 

Applies to 

Symptom Solution(s) 

Lights Foggers 

& Snow 

Controllers Dimmers

& Chaser 

Auto shut off 

Check fan thermal switch reset 

9

 

 

 

 

Beam is very dim or not 
bright 

Clean optical system or replace lamp 

Check 220/110v switch for proper setting 

9

 

 

 

 

Breaker/Fuse keeps 
blowing 

Check total load placed on device 

 

 

 

9

 

Chase is too slow 

Check users manual for speed adjustment 

9

 

 

9

 

9

 

Device has no power 

Check for power on Mains. 

Check device’s fuse. (internal and/or external) 

9

 

 

9

 

9

 

Lamps cuts off 
sporadically  

Possible bad lamp or fixture is overheating. 

Lamp may be at end of its life. 

9

 

 

 

 

Motor movements are 
jerky or jumpy 

Possible bad motor driver or sensors 

Check  polarity switch on controller 

9

 

 

9

 

 

Moves slow 

Check 220/110v switch for proper setting 

9

 

 

 

 

No flash 

Re-install bulb, may have shifted in shipping 

9

 

 

 

 

No light output 

Check slip ring & brushes for contact  

Install bulb 

Call service technician 

9

 

 

 

 

Relay will not work 

Check reset switch 

Check cable connections 

 

 

 

9

 

Remote does not work 

Make sure connector is firmly connected to device 

9

 

9

 

 

 

Unit wobbles when 
rotating 

Check for damages possibly incurred during shipping 

9

 

 

 

 

Содержание CH-302A

Страница 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com CH 302A Cosmos 2 0 USER MANUAL ...

Страница 2: ...DUCT OVERVIEW H4 HSETUP H5 HLAMP H5 HLamp Installation H5 HPOWER H5 HMOUNTING H5 HOPERATING INSTRUCTIONS H6 HGeneral operation H6 HFlash On Off Rotary knob H6 HRotation rotary knob H6 HCON EF2 Wired Remote Optional H6 HAPPENDIX H7 HGENERAL MAINTENANCE H7 HRETURNS PROCEDURE H7 HCLAIMS H7 HGENERAL TROUBLESHOOTING H8 HLAMP IN SERIES WIRING DRAWING FOR 230V OPERATION H9 HTECHNICAL SPECIFICATIONS H9 ...

Страница 3: ...ion If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Mak...

Страница 4: ...4 interchangeable colored lens installed on dome 24 additional clear lens included centered rigging point for single clamp mount easy lamp access on board control features flash full on switch flash speed knob rotation speed knob optional wired remote 360 rotation on both axis wide area light dispersion Product Overview Power input Dome fixture cover Disc fixture cover 5 pin XLR to remote controll...

Страница 5: ...the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All fixtu...

Страница 6: ...smos 2 0 to flash intermittently The rate of the flash can be adjusted using the FLASH rotary knob ROTATION ROTARY KNOB The ROTATION rotary knob affects the speed of the mechanical rotations on the Cosmos 2 0 CON EF2 WIRED REMOTE OPTIONAL The CON EF2 provides an extension to the same on board controls on the Cosmos 2 0 This optional controller would provide the user the ability to shift from fast ...

Страница 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Страница 8: ... device s fuse internal and or external 9 9 9 Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life 9 Motor movements are jerky or jumpy Possible bad motor driver or sensors Check polarity switch on controller 9 9 Moves slow Check 220 110v switch for proper setting 9 No flash Re install bulb may have shifted in shipping 9 No light output Check slip ...

Страница 9: ...mps in series is the most effective and economical method Tests have shown that the lamp will hold much longer than their 230V counter parts Technical Specifications WEIGHT DIMENSIONS Length 216 mm 8 5 in Width 432 mm 17 in Height 356 mm 14 in Weight 5 67 Kg 12 5 lbs POWER Switch selectable power setting 115V 60 Hz or 230V 50 Hz AC input 3 prong IEC 60320 C14 LAMPS 64514 x 2 115V 300 hr 300W THERM...

Отзывы: