background image

DMX Address Quick Reference Chart 

Dip Switch Position 

DMX DIP 

SWITCH SET 

#9  0 0 0 0  0 0 0 0 1 1 1 1 1 1 1 1 

0=OFF #8 

0 0 0 0  1 1 1 1 0 0 0 0 1 1 1 1 

1=ON #7 

0 0 1 1  0 0 1 1 0 0 1 1 0 0 1 1 

X=OFF or ON  #6  0 1 0 1  0 1 0 1 0 1 0

 

0 1 0 1 

#1 #2 #3 #4 #5 

 

0 0 0 0 0    32 

64 96 128 160 192 224 256 288 320 352  384 416 448 480

1 0 0 0 0  1 33 65 97 129 161 193 225 257 289 321 353  385 417 449 481
0 1 0 0 0  2 34 66 98 130 162 194 226 258 290 322 354  386 418 450 482
1 1 0 0 0  3 35 67 99 131 163 195 227 259 291 323 355  387 419 451 483
0 0 1 0 0  4 36 68 100 132 164 196 228 260 292 324 356  388 420 452 484
1 0 1 0 0  5 37 69 101 133 165 197 229 261 293 325 357  389 421 453 485
0 1 1 0 0  6 38 70 102 134 166 198 230 262 294 326 358  390 422 454 486
1 1 1 0 0  7 39 71 103 135 167 199 231 263 295 327 359  391 423 455 487
0 0 0 1 0  8 40 72 104 136 168 200 232 264 296 328 360  392 424 456 488
1 0 0 1 0  9 41 73 105 137 169 201 233 265 297 329 361  393 425 457 489
0 1 0 1 0  10 42 74 106 138 170 202 234 266 298 330 362  394 426 458 490
1 1 0 1 0  11 43 75 107 139 171 203 235 267 299 331 363  395 427 459 491
0 0 1 1 0  12 44 76 108 140 172 204 236 268 300 332 364  396 428 460 492
1 0 1 1 0  13 45 77 109 141 173 205 237 269 301 333 365  397 429 461 493
0 1 1 1 0  14 46 78 110 142 174 206 238 270 302 334 366  398 430 462 494
1 1 1 1 0  15 47 79 111 143 175 207 239 271 303 335 367  399 431 463 495
0 0 0 0 1  16 48 80 112 144 176 208 240 272 304 336 368  400 432 464 496
1 0 0 0 1  17 49 81 113 145 177 209 241 273 305 337 369  401 433 465 497
0 1 0 0 1  18 50 82 114 146 178 210 242 274 306 338 370  402 434 466 498
1 1 0 0 1  19 51 83 115 147 179 211 243 275 307 339 371  403 435 467 499
0 0 1 0 1  20 52 84 116 148 180 212 244 276 308 340 372  404 436 468 500
1 0 1 0 1  21 53 85 117 149 181 213 245 277 309 341 373  405 437 469 501
0 1 1 0 1 

 

22 54 86 118 150 182 214 246 278 310 342 374  406 438 470 502

1 1 1 0 1 

23 55 87 119 151 183 215 247 279 311 343 375  407 439 471 503

0 0 0 1 1 

24 56 88 120 152 184 216 248 280 312 344 376  408 440 472 504

1 0 0 1 1 

25 57 89 121 153 185 217 249 281 313 345 377  409 441 473 505

0 1 0 1 1 

26 58 90 122 154 186 218 250 282 314 346 378  410 442 474 506

1 1 0 1 1 

27 59 91 123 155 187 219 251 283 315 347 379  411 443 475 507

0 0 1 1 1 

28 60 92 124 156 188 220 252 284 316 348 380  412 444 476 508

1 0 1 1 1 

29 61 93 125 157 189 221 253 285 317 349 381  413 445 477 509

0 1 1 1 1 

30 62 94 126 158 190 222 254 286 318 350 382  414 446 478 510

1 1 1 1 1  31 63 95 127 159 191 223 255 287 319 351 383  415 447 479 511

Dip Switch Position                                                   DMX  Address 

Vue™ 4.1 User Manual 

15 

7/11/2008 11:57 AM

 

Содержание Camera Accessories

Страница 1: ... Sound Activated DMX512 Master Slave Autoswitching Transformer Replaceable Fuse User Serviceable Duty Cycle Vue 4 1 USER MANUAL 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com ...

Страница 2: ...Link 8 Master Slave Fixture Linking 9 Mounting 9 Orientation 9 Rigging 9 Slide Rails Adjustment 9 4 Operating Instructions 10 Menu Functions 10 Operation 11 Stand Alone Mode Sound Active Auto Mode 11 Master Slave Mode Master Sound Master Auto 11 DMX Mode 11 DMX Channel Values 12 Setting the starting address 14 DMX Quick Reference Chart 14 Blow out Diagram 16 Vue 4 1 Maintenance Guide 21 Technical ...

Страница 3: ... switching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V AC 50 60 Hz All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resisto...

Страница 4: ...mp or fuse and be sure to replace with same lamp source Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Re...

Страница 5: ...automated programs via DMX Built in sound activated programs via master slave or DMX Additional Features Adjustable hanging bracket with slide rail Additional power output max 25 units 120V see manual for details DMX Channel Summary CHANNEL FUNCTION 1 Operating mode 2 Cluster 1 3 Cluster 2 4 Cluster 3 5 Cluster 4 6 Cluster 5 7 Cluster 6 8 Strobe 9 Motor Rotation speed Vue 4 1 User Manual 5 7 11 20...

Страница 6: ...utput Connector Tilt Adjustment Knob Hanging Bracket Microphone Digital Display Front Lens Slide Rail Sound Sensitivity Knob DMX Output Connector DMX Input Connector AC Power Input Fuse Vue 4 1 User Manual 6 7 11 2008 11 57 AM ...

Страница 7: ...link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 meters 1640 ft Maximum recommended number of fixtures on a serial data link 32 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase CHAUVET c...

Страница 8: ... you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter CHAUVET Model No DMX5M or DMX5F The chart below details a proper cable conversion Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter CHAUVET Model No DMX5M or DMX5F The chart below details a proper cable conversion 3 PIN TO 5 PIN CONVERSION...

Страница 9: ... fixture may be mounted in any safe position provided there is adequate room for ventilation RIGGING It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into cons...

Страница 10: ...rrent program SET A A 000 a 042 Selects the current program in standalone SUND This is displaying that the fixture is operating in sound activation mode AUTO This is displaying that the fixture is operating in auto activation mode Navigating the menu 1 Press Mode to scroll through the menu options 2 Press Enter to select a function to modify 3 Use the Up and Down buttons to modify the selected men...

Страница 11: ...y turning the knob clockwise increases the sensitivity Master Slave Mode Master Sound Master Auto This mode will allow you to link up to 32 units together without a controller The first fixture in the daisy chain will automatically be assigned as the master and each fixture following will be assigned as slave fixtures Note for this mode you must not connect a DMX controller to the fixtures Note In...

Страница 12: ...069 070 Ù 074 075 Ù 079 080 Ù 084 085 Ù 089 090 Ù 094 095 Ù 235 236 Ù 245 246 Ù 255 Control Operating Mode Individual cluster control with channels 2 7 Auto 1 Auto 2 Auto 3 Auto 4 Auto 5 Auto 6 Auto 7 Auto 8 Auto 9 Auto 10 Auto 11 Auto 12 Auto 13 Auto 14 Auto 15 Auto 16 Full On Auto 17 Auto with rotation Sound mode with rotation Vue 4 1 User Manual 12 7 11 2008 11 57 AM ...

Страница 13: ...Red Amber Red White Green White Blue White Amber White Green Red Blue Red Amber Red Blue Green Amber Green Amber Blue Red Red White Red Green White Red Blue White Red Amber White Red Green Red Red Blue Red Red Amber Red Red Blue Green Red Amber Green Red Amber Blue Red Green Red White Red Blue Red White Red Amber Red White Red Blue Green Red Red Amber Green Red Red Amber Blue Red Red Amber Blue Wh...

Страница 14: ...alue switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the previous subtraction 5 Repeat steps three and ...

Страница 15: ...37 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498 1 1 0 0 1 ...

Страница 16: ...sembly P222 VUE41 2 Front Fresnel lens P150 VU2LNS 3 Bracket adjustment knob of 2 P111 VUEBRT 4 Electronic transformer P140 VUEIITR 5 Display PCB P172 VUE41 6 Master PCB P177 VUE41 7 Stepper motor P110 VUE41 2 5 4 6 7 Vue 4 1 User Manual 16 7 11 2008 11 57 AM ...

Страница 17: ...Electrical Connections Diagram Vue 4 1 User Manual 17 7 11 2008 11 57 AM ...

Страница 18: ...LED Driver PCB Schematics Vue 4 1 User Manual 18 7 11 2008 11 57 AM ...

Страница 19: ...Display PCB Schematics Display PCB Schematics Vue 4 1 User Manual 19 7 11 2008 11 57 AM ...

Страница 20: ...Master PCB Schematics Vue 4 1 User Manual 20 7 11 2008 11 57 AM ...

Страница 21: ...d or external Device has no power Check device s fuse internal Check for power on Mains Note In the event of autoswitching transformer failure the unit can be sent in for repair however a replacement part can be ordered directly from CHAUVET Part P140 VUEIITR Fixture is not responding to DMX Check Control Panel settings for correct addressing Check DMX cables Check polarity switch settings on the ...

Страница 22: ...e fixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is w...

Страница 23: ...he external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET and request RMA prior to shipping the fixtur...

Страница 24: ... Power Output 25 units max at 120V Power Output 50 units max at 240V LIGHT SOURCE LED 282 66 red 90 green 66 blue 18 white 42 amber LEDs 100 000 hrs PHOTO OPTIC Coverage Angle 46 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USI...