Technical Specifications 

 

WEIGHT & DIMENSIONS  
Length........................................................................................................................ 521 mm (20.5 in) 
Width.......................................................................................................................... 470 mm (18,5 in) 
Height ........................................................................................................................... 533 mm (21 in) 
Weight................................................................................................................... 43.68 Kg (96.30 lbs) 
 
POWER 
Power settings (internal tap)........................................................................115V 60 Hz or 230V 50 Hz 
AC input ......................................................................................................... 3 prongs IEC 60320 C14 
European version ............................................................................................................... 240V 50 Hz 
Current draw .......................................................................................................(peak 750W @ 120V) 
 
LAMP 
HSR575 ............................................................................................................ 1000 hr, 7200K, 575W 
 
PHOTO OPTIC 
Beam Angle ............................................................................................................................. 7

° ~ 40° 

 
THERMAL 
Maximum ambient temperature ......................................................................................... 50

° (122° F)

 

 
CIRCUIT PROTECTION 
ART-575W ....................................................................................... Magnetic Circuit Breaker with GFI 
Fuse (120V) .............................................................................................. 20mm Glass 15A Fast Blow 
Fuse (230V) .............................................................................................. 20mm Glass 10A Fast Blow 
 
CONTROL & PROGRAMMING 
Data input ............................................................................................. locking 3-pin XLR male socket 
Data output ........................................................................................ locking 3-pin XLR female socket 
Data pin configuration ............................................................................pin 1 shield, pin 2 (-), pin 3 (+) 
Protocols.....................................................................................................................DMX-512 USITT 
DMX Channels ....................................................................................................................................8 
 
ORDERING INFORMATION 
Spectrum

 575

W............................................................................................................... ART-575W 

 

Technical Support 

Address: 

Service Dept. 

 

3000 N 29

th

 Ct, Hollywood, FL 33020 (U.S.A.) 

Support (Email):  

[email protected]

 

Telephone: 

(954) 929-1115 - (Press 4) 

Fax: 

(954) 929-5560 - (Attention: Service) 

Website: 

http://www.chauvetlighting.com 

 

Содержание ART-575W

Страница 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 06 15 17 08 ART 575W Spectrum 575W USER MANUAL ...

Страница 2: ...ION 8 Orientation 8 Floor Mounting 8 Truss Mounting 8 Power configuration 9 Wiring the connector 9 Data Cables Linking 9 OPERATING INSTRUCTIONS 10 OPERATING MODES 10 Master Slave Stand Alone 10 Accessing internal programs in Master mode 11 Built in Programs chart 12 DMX Mode 13 Setting the starting address 13 APPENDIX 16 DMX PRIMER 16 Fixture Linking 16 DMX CHANNEL VALUES 17 PHOTO METRICS 18 DIPSW...

Страница 3: ... on decal or rear panel of the fixture To prevent risk of fire or shock make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace...

Страница 4: ...iable mechanical dimmer 0 100 Variable mechanical zoom 7 40 32 built in color change programs at varying speeds Features Durable and weatherproof IP 54 rated housing Very low noise operation convection cooled look for a fan No control necessary Master Slave operation Frosted lens diffuser Micro stepping motors Thermal switch protection DMX Channel Summary CHANNEL FUNCTION 1 Vector speed 2 Yellow 3...

Страница 5: ...6 446 410 445 7 289 2 Front View Side View 528 11 38in 17 6in 16 1in 17 5in Top View 20 8in 428 289 2 326 396 80 150 344 254 100 100 Bottom View 16 9in 13 5in 12 8in 11 4in 5 9in 3 15in 10 0in 3 9in 15 6in Projection angle Carrying handles Product Overview ...

Страница 6: ... cloth before installation LAMP INSTALLATION 1 Remove the back cover plate by removing all 8 screws on the rear of the fixture 2 Remove the screws D and E on the lamp plate Pull out the lamp cover plate 3 With lamp socket plate out and the lamp accessible if replacing the lamp remove old lamp first 4 Holding the new lamp by its base align the small pin on the lamp with the small hole in the socket...

Страница 7: ...spot by having it widen and spread across the entire spot or moving the hot spot so that it covers as much of the beam spot area as possible Power Warning Verify that the internal multi tap transformer is set to match the line voltage applied and that the proper fuse is installed for the appropriate voltage setting All fixtures must be connected to circuits with a suitable Earth Ground To determin...

Страница 8: ...access and routine maintenance Safety cables should always be used The fixture must have a minimum of 1 meter distance from combustible materials FLOOR MOUNTING 1 If connected be sure to always disconnect from main power before installing fixture 2 The ART 575W is constructed with mounting bracket yoke 3 Bolt fixture onto a leveled floor surface using floor mount holes and 3 8 diameter bolts TRUSS...

Страница 9: ...Wires Connector Live L Black Brown Yellow or brass Neutral N White Blue Silver Ground W Green Yellow Green Green Consult an electrician if you have any doubts about the proper wiring connection during your installation Data Cables Linking Data linking is required for synchronized operation as well as DMX controller operation The ART 575W fixture is equipped with two 24 AWG data cables that exit th...

Страница 10: ...wered the program selected will automatically execute If you own multiple Spectrum fixtures you can link them together so that they all follow one leader in synchrony called the master This operating state is called Master Slave mode The Master Slave mode allows you to link multiple units in a daisy chain fashion In this mode the first unit in the daisy chain will automatically command all other u...

Страница 11: ...ue of each switch in the ON position will provide the channel address Determining which switches to toggle ON given a specific channel address can be accomplished in the following manner By subtracting the largest switch value possible from the selected channel address which does not cause a negative number This is the exact method for computing DMX address values as well and this section will be ...

Страница 12: ...0 0 Every 60 seconds Rapid Color Change Red Orange Green Cyan Light Blue Blue UV Filter Purple Magenta Auvergne 19 1 1 0 0 1 0 0 0 0 0 Every 5 seconds 20 0 0 1 0 1 0 0 0 0 0 Every 10 seconds 21 1 0 1 0 1 0 0 0 0 0 Every 30 seconds 22 0 1 1 0 1 0 0 0 0 0 Every 60 seconds Smooth Color Change Red Orange Green Cyan Light Blue Blue UV Filter Purple Magenta Auvergne 23 1 1 1 0 1 0 0 0 0 0 Every 5 second...

Страница 13: ...dress from 1 to 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 6 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and notate the start addres...

Страница 14: ...n DMX mode Therefore each fixture must be spaced and addressed in 8 channel increments as illustrated below The page following contains a cheat sheet which contains all possible DMX address values and associated dipswitch settings ON 1 2 3 4 5 6 7 8 9 10 11 12 1 2 4 8 16 32 64 128 256 DMX values 1 DMX 001 ON 1 2 3 4 5 6 7 8 9 10 11 12 1 2 4 8 16 32 64 128 256 DMX values 2 DMX 009 ON 1 2 3 4 5 6 7 ...

Страница 15: ...0 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 ...

Страница 16: ...of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whi...

Страница 17: ...t Blue Rose Red 5 seconds 10 seconds 30 seconds 60 seconds Smooth Color Change Red Yellow Green Blue Light Blue Rose Red 5 seconds 10 seconds 30 seconds 60 seconds Rapid Color Change Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink 5 seconds 10 seconds 30 seconds 60 seconds Smooth Color Change Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink 5 seconds 10 secon...

Страница 18: ... 1 2 2 3 3 0 2900 7200 1250 500 400 320 620 LUX 5 3 10 15 20 25 30 3 64 2 18 7 28 10 92 14 56 18 20 21 84 40 4 4 5 5 6 6 Distance m Diameter m 7 Beampath 1 1 2 2 0 8200 23000 2300 800 620 560 1200 LUX 5 3 10 15 20 25 30 0 61 0 37 1 22 1 83 2 45 3 06 3 67 7 Distance m Diameter m ...

Страница 19: ...06 15 17 08 Dipswitch Location Remove fixture front cover clips are located on both sides Front of fixture exposed Dipswitch is accessible without removing PCB cover however a photograph has been taken with the PCB cover removed Dipswitches ...

Страница 20: ...n the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid...

Страница 21: ...ible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movements...

Страница 22: ...t temperature 50 122 F CIRCUIT PROTECTION ART 575W Magnetic Circuit Breaker with GFI Fuse 120V 20mm Glass 15A Fast Blow Fuse 230V 20mm Glass 10A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 8 ORDERING INFORMATION Spectrum 575W ART 575W Technical...

Отзывы: