Chauvet Arena Hazer 3 Скачать руководство пользователя страница 1

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

User Manual

 

Содержание Arena Hazer 3

Страница 1: ...User Manual ...

Страница 2: ...ing 7 Orientation 7 Rigging 7 4 Operation 8 Control Panel Operation 8 Menu Map 8 DMX Channel Assignments and Values 8 Configuration DMX Mode 9 Starting Address 9 Configuration Stand alone Modes 10 Timer Mode 10 Volume Mode 10 5 Technical Information 11 General Maintenance 11 Storage 11 General Troubleshooting 12 Returns Procedure 13 Contact Information 13 DMX Primer 14 Starting Address 14 Fixture ...

Страница 3: ...fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status Menu Settings A sequence of menu options to be followed ON A value to be entered or selected Icons Icon Meaning This paragraph contains critical installation configuration or operation information Failu...

Страница 4: ... fuse Make sure to replace the fuse with another of the same type and rating The maximum ambient temperature Ta is 104 F 40 C Do not operate this product at higher temperatures In the event of a serious operating problem stop using the unit immediately Never try to repair this product Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized te...

Страница 5: ...2 Page 5 of 16 2 INTRODUCTION Product Overview Fluid reservoir cover Haze output nozzle Air filter Rubber feet 4 Carrying handle LCD screen Control Panel DMX 3 pin 5 pin Power Switch ON OFF Power Input NEUTRIK powerCON A Main Breaker ...

Страница 6: ...onnect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Resetting the Breaker This product is equipped with a resettable circuit breaker on the power input circuit In the event that the breaker trips the power will be cut to the entire product Please see the instructions below for resetting this breaker 1 Remove ...

Страница 7: ...er 3 Please see the Technical Specifications section of this manual for weight information Always consider ease of access to the unit for maintenance and programming purposes before deciding on a location for this product Overhead rigging is potentially dangerous and should only be attempted by certified experienced riggers The installer user is responsible for ensuring that the Arena Hazer 3 is r...

Страница 8: ...escription Interval Set 1 200s Modify the interval time for the timer mode Duration Set 1 200s Modify the duration time for the timer mode Timer Out 1 100 Modify the haze volume for the timer mode Volume Out 1 100 Modify the volume output for volume mode Fan Speed OFF 1 100 Modify the fan speed for both the time volume modes DMX512 Add 1 512 Set the DMX starting address Fluid Sensor ON OFF Turn on...

Страница 9: ...s you must always consider the number of DMX channels assigned to the selected DMX mode If you choose a starting address that is too high you could limit the access to some of the channels of the DMX mode in use The Arena Hazer 3 uses up to two DMX channels which defines the highest configurable address to 511 If you are not familiar with the DMX protocol you may refer to the DMX Primer section in...

Страница 10: ...P or DOWN to select the volume of haze 9 Press FUNCTION repeatedly until Fan Speed shows on the display 10 Use UP or DOWN to select fan speed Setting this to OFF will disable the fan in Timer Mode 11 Press TIMER to activate the mode with the above settings Volume Mode To enable the Volume mode do the following 1 Connect this product to a suitable power outlet 2 Turn this product on 3 Press FUNCTIO...

Страница 11: ... in a well ventilated area until the tank is almost empty Do not allow the pump to run dry 5 Cleaning is now complete Refill with fog liquid Run the machine briefly to clear any cleaning solution from the pump and heater FCQ Fog Cleaner Quart was specifically developed by Chauvet to clean your Arena Hazer 3 Make sure you use FCQ regularly to increase the life of your product Storage Before storing...

Страница 12: ...e the right fader s on the controller Wrong DMX personality on the fixture Set the correct DMX fixture s personality Assign the faders accordingly Wrong polarity setting on the DMX controller Change the signal polarity on the controller Loose or damaged DMX cable Check the DMX cable before the faulty unit Internal problem Send product for repair Intermittent DMX Problems Signal cables are not DMX ...

Страница 13: ...ur name Your address Your phone number The RMA number A brief description of the problem Be sure to pack the fixture properly Any shipping damage resulting from inadequate packaging will be the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace returned product s Cont...

Страница 14: ...l control fixture A This means that the user should assign the starting address of fixture B to 005 or higher For a starting address of 005 the DMX controller would use channels 005 to 010 to control fixture B It is possible to control multiple fixtures of the same type by assigning each one of them the same starting address In this case all the fixtures would respond in unison synchronized to the...

Страница 15: ...tor on the other end The DMX protocol indicates that the XLR connectors must have five pins However most lighting fixtures use the 3 pin XLR connector The pin assignment of the 3 pin and 5 pin XLR connectors in a DMX cable is as follows Male Plug Female Plug Signal 3 Pin 5 Pin 5 Pin 3 Pin Signal Common 1 1 1 1 Common Data 2 2 2 2 Data Data 3 3 3 3 Data Not used 4 4 Not used Not used 5 5 Not used Y...

Страница 16: ... V 60 Hz 230 V 50 Hz Consumption 1 640 W 13 71 A 1 640 W 6 86 A Internal breaker size 15 A 125 V 8 A 250 V Power I O Input Connectors Neutrik powerCON A Cord plug Edison US market Operation Consumption Capacity Heat up Time Tank Capacity Fluid Consumption 2 min 2 5 l 18 ml min Approved Fluids Chauvet Pro Haze Fluid Gallon Chauvet Haze Fluid Gallon PHF HFG Thermal Maximum External Temp Cooling Syst...

Отзывы: