Chauvet Arena HAZER 2 Скачать руководство пользователя страница 13

 
Arena Hazer™ 2 User Manual 

13 

4/20/2010 4:23 PM

 

5.

 

A

PPENDIX

 

DMX Primer 

There are 512 channels in a DMX connection. Channels may be assigned in any manner. A fixture 

capable of receiving DMX will require one or a number of sequential channels. The user must assign 

a starting address on the fixture that indicates the first channel reserved in the controller. There are 

many different types of DMX controllable fixtures and they all may vary in the total number of 

channels required. Choosing a start address should be planned in advance. Channels should never 

overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set 

incorrectly. You can however, control multiple fixtures of the same type using the same starting 

address as long as the intended result is that of unison movement or operation. In other words, the 

fixtures will be slaved together and all respond exactly the same.  

DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is 

where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which 

the fixtures are connected is not important and has no effect on how a controller communicates to 

each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures 

using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The 

shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). 

General Maintenance 

To maintain optimum performance and minimize wear, fixtures should be cleaned frequently.  Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should 

be cleaned at least twice a month. Dust build up reduces light output performance and can cause 

overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off 

fixture before conducting maintenance. 

 

Unplug fixture from power.  

 

Use a vacuum or air compressor and a soft brush to remove dust collected on external 

vents. 

 

Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl 

Alcohol and a soft lint free cotton cloth or lens tissue.  

 

Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens.  

 

Gently polish optical surfaces until they are free of haze and lint.  

The cleaning of external optical lenses and/or mirrors must be carried out periodically to optimize light 

output. Cleaning frequency depends on the environment in which the fixture operates. Damp, smoky 
or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. Clean 

with soft cloth using normal glass cleaning fluid. Clean the external optics at least every 20 days. 

Clean the fixture at least every 30/60 days. 

 

Always dry the parts carefully after cleaning them. 

 

Never spin a fan using compressed air.

Содержание Arena HAZER 2

Страница 1: ...d FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Sound Activated DMX Master Slave 115 V 230 V Switch Resettable Breaker User Serviceable Duty Cycle ...

Страница 2: ...G INSTRUCTIONS 9 CONFIGURING THE STARTING ADDRESS 9 CONTROL PANEL FUNCTIONS 9 CONTROL PANEL FUNCTIONS CONT 10 DMX 10 DMX CHANNEL VALUES 10 ADJUSTABLE BLOWER ANGLES 10 LED INDICATORS 11 AUTO CUT OFF FEATURE 11 GENERAL TROUBLESHOOTING 12 CONTACT US 12 5 APPENDIX 13 DMX PRIMER 13 GENERAL MAINTENANCE 13 WARNING 14 Maintenance 14 Storage 14 FIXTURE LINKING 15 Data Cabling 15 DMX Data Cable 15 Cable Con...

Страница 3: ...the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons Th...

Страница 4: ...ed Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs...

Страница 5: ...ed remote or DMX Adjustable blower speed via wired remote or DMX Additional Features Adjustable blower angle 3 pin and 5 pin DMX connections Wired remote with LCD screen 2 5 L tank capacity 8 min heat up Low fluid indicator and auto shut down LED illuminated tank Water based hazer DMX Channel Summary CHANNEL FUNCTION 1 Blower 2 Haze ...

Страница 6: ...2 User Manual 6 4 20 2010 4 23 PM Product Overview 5 pin DMX in out Door latch Wired remote with LCD backlit control panel 3 pin DMX in out LED illuminated tank Power switch Power in Breaker Carrying handle Blower ...

Страница 7: ...Arena Hazer 2 User Manual 7 4 20 2010 4 23 PM Product Dimensions ...

Страница 8: ...t this breaker trips you may reset it very easily 1 Unplug the product from the power outlet 2 Allow to cool for 5 15 min 3 Press on the breaker button until it remains in place In the event that this breaker will not reset contact CHAUVET for troubleshooting The fixture may need to be serviced LED Illuminated Tank The fluid tank on this hazer is equipped with LEDs in order to provide visual fluid...

Страница 9: ...annels If this is your first time using DMX we recommend reading the DMX Primer section in the Appendix Control Panel Functions Access control panel functions using the six buttons located underneath the LCD Display on the included wired remote The Control Panel shows the current state of the unit It also has a sub menu which is used for setting the DMX starting address You may select any combinat...

Страница 10: ...ection in the Appendix of this manual 1 Press FUNCTION 2 Using FAN ADDRESS and buttons select the desired DMX address 3 Press FUNCTION DMX Channel Values CHANNEL VALUE FUNCTION 1 000 255 Blower 0 100 2 000 255 Haze 0 100 Adjustable Blower Angles The blower output angle may be adjusted by using a knob located on the side of the hazer 1 Loosen the knob by turning it counter clockwise 2 Using the kno...

Страница 11: ...t and the tank LED is flashing blue It will take approximately 30 seconds to 1 minute for this feature to engage once the fluid has emptied from the tank In order for the hazer to automatically reset the trigger must be released This may be from the wired remote or via a DMX controller If it is via a DMX controller then the DMX channel will have to be brought to a value of 000 0 in order to allow ...

Страница 12: ...able connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier right after fixture with strong signal Too many fixtures Install an optically coupled DMX splitter after unit 32 Interference from AC wires Keep DMX cables...

Страница 13: ...ir cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust bu...

Страница 14: ...aning solution to tank Plug unit in and begin warm up 2 Run the unit in a well ventilated area until the tank is almost empty Do not allow the pump to run dry 3 Replace nozzle 4 Cleaning is now complete Refill with fog liquid Run the machine briefly to clear any cleaning solution from the pump and heater 5 Do not operate the machine without liquid at any time Storage 1 When storing the machine run...

Страница 15: ...n cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable must have the following characteristics Type shielded 2 conductor twiste...

Страница 16: ...ERSION CHART Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not used Pin 4 Not used Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin c...

Страница 17: ...n proper UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibi...

Страница 18: ...umption 47 ml min Output 3 500 cfm THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input 3 pin locking 3 pin XLR male socket Data output 3 pin locking 3 pin XLR female socket Data pin configuration 3 pin pin 1 shield pin 2 pin 3 Data input 5 pin locking 5 pin XLR male socket Data output 5 pin locking 5 pin XLR female socket Data pin configuration 5 pin pin 1 shield pin 2 pi...

Отзывы: