Chauvet 86 Скачать руководство пользователя страница 10

 
5. Appendix 

10 

1/6/2010 10:35 AM 

5.

 

A

PPENDIX

 

DMX Primer 

There are 512 channels in a DMX connection. Channels may be assigned in any manner. A fixture 

capable of receiving DMX will require one or a number of sequential channels. The user must assign 

a starting address on the fixture that indicates the first channel reserved in the controller. There are 

many different types of DMX controllable fixtures and they all may vary in the total number of 

channels required. Choosing a start address should be planned in advance. Channels should never 

overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set 

incorrectly. You can however, control multiple fixtures of the same type using the same starting 

address as long as the intended result is that of unison movement or operation. In other words, the 

fixtures will be slaved together and all respond exactly the same.  

DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is 

where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which 

the fixtures are connected is not important and has no effect on how a controller communicates to 

each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures 

using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The 

shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). 

 

General Maintenance 

To maintain optimum performance and minimize wear, fixtures should be cleaned frequently.  Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should 

be cleaned at least twice a month. Dust build up reduces light output performance and can cause 

overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off 

fixture before conducting maintenance. 

 

Unplug fixture from power.  

 

Use a vacuum or air compressor and a soft brush to remove dust collected on external 

vents. 

 

Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl 

Alcohol and a soft lint free cotton cloth or lens tissue.  

 

Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens.  

 

Gently polish optical surfaces until they are free of haze and lint.  

The cleaning of external optical lenses and/or mirrors must be carried out periodically to optimize light 

output. Cleaning frequency depends on the environment in which the fixture operates. Damp, smoky 

or particularly dirty 

surroundings can cause greater accumulation of dirt on the unit’s optics. Clean 

with soft cloth using normal glass cleaning fluid. Clean the external optics at least every 20 days. 

Clean the fixture at least every 30/60 days. 

 

Always dry the parts carefully after cleaning them. 

 

Never spin a fan using compressed air. 

Содержание 86

Страница 1: ... 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...3 SETUP 6 AC POWER 6 Power Linking 6 MOUNTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 CONFIGURING THE STARTING ADDRESS 8 DMX OPERATION 8 MASTER SLAVE MODE AUTO MODE STATIC 8 STANDALONE OPERATION 8 Automatic 8 Sound Active 9 Static 9 Fixture Linking 9 DMX CHANNEL VALUES 9 5 APPENDIX 10 DMX PRIMER 10 GENERAL MAINTENANCE 10 DATA CABLING 11 DMX Data Cable 11 Cable Connectors 11 FIXTURE LI...

Страница 3: ...r text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This manual ...

Страница 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by un...

Страница 5: ...tic color strobing and pulse effects with or without DMX controller Additional Features Additional power output max 37 units Built in automated programs via master slave Built in sound activated programs via master slave Product Overview Microphone Sensitivity Adjustment Knob Power In Microphone DMX In DIP Switches Power Out DMX Out Fuseholder ...

Страница 6: ...switch To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the ediso...

Страница 7: ...r a hanging clamp The hole in each bracket is 13 mm in size When rigging consider routine maintenance and control panel access Please see the following steps for installation If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this When aiming the fixtures you may u...

Страница 8: ... set the starting address for this mode If this is your first time using DMX then it is recommended that you refer to the DMX Primer section in the Appendix of this manual Mode DIP switches DMX 1 9 set to the DMX starting address 10 On Master Slave Mode Auto Mode Static This mode allows a single unit to run a standalone program while 1 or more other units follow the same operation This requires th...

Страница 9: ...sitivity adjustment knob Please see the chart below for further explanation Mode DIP switches Strobe 9 On Static This unit has 3 different standalone static dimming levels These are accessed via the DIP switches on the back of the fixture Please see the chart below for further explanation Mode DIP switches Minimum Intensity 1 On Medium Intensity 2 On Maximum Intensity 1 2 On Fixture Linking In ord...

Страница 10: ...e with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up ...

Страница 11: ...your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number...

Страница 12: ... CHART Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not used Pin 4 Not used Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connect...

Страница 13: ...l wiring internal and or external Device does not power up No power Check for power on power outlet Loose power cord Check power cord Fixture is not responding to DMX Wrong DMX addressing Check Control Panel and unit addressing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faul...

Страница 14: ... UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of ...

Страница 15: ...ower Consumption 120 VAC 60 Hz 11 W 0 2 A max 0 2 A inrush Power Consumption 230 VAC 50 Hz 14 W 0 1 A max 0 2 A inrush Power output 37 units max Fuse F 2 A 250 V LIGHT SOURCE LED 86 x 5 mm white 100 000 hrs PHOTO OPTIC Luminance 1 m 1 430 lux Beam Angle 20 Field Angle 38 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION DIAMONDsplash 86 DIAMONDSPLASH86 WARRANTY INFORMATION Warran...

Отзывы: