EN
6
WELL Panel QRG Rev. 6
QUICK REFERENCE GUIDE
Red Shift
On
Turns on or off Red Shift (amber LEDs imitate lamp when
dimming)
Off
Master/Slave
Master
DMX mode (Master)
Slave
Slave mode
Dimmer Mode
Off
Linear dimmer
Dimmer 1–3
Dimming curves
Dimmer 1
(fast) to
Dimmer 3
(slow)
Dimmer Curve
Linear
Liner dimmer
Square
Square curve dimmer
I Squa
Reverse square curve dimmer
Scurve
S curve dimmer
White Balance
Off
Uses factory default white setting
Manual
Red
125–255
Sets red LED maximum value
Green
Sets green LED maximum value
Blue
Sets blue LED maximum value
White
Sets white LED maximum value
LED
Frequency
600Hz
Sets the PWM frequency
1200Hz
2000Hz
4000Hz
6000Hz
25KHz
Wireless
Setting
Receive On/Off
On
Enables/disables wireless DMX
Off
Receive Reset
No
Resets wireless receiver
Yes
Line Voltage
Power Loss
Mode
Stay In State
If
line
power is lost, the fixture will continue to function as
programmed under
battery
power (default)
All At Full
After 5 seconds of
line
power loss, all LEDs will go to full power
(returns to normal operation when line power is restored)
Dim Out
After 5 seconds of
line
power loss, the LEDs will dim in a 10
second fade to black (returns to normal operation when line
power is restored)
Run Time
Off
Maximum intensity for all LEDs
3 Hours
Reduced intensity, limiting battery run time to 3 hours
5 Hours
Reduced intensity, limiting battery run time to 5 hours
8 Hours
Reduced intensity, limiting battery run time to 8 hours
12 Hours
Extends battery to the maximum run time of 12 hours
Back Light
10S
Turns off display backlight after 10 seconds of inactivity
30S
Turns off display backlight after 30 seconds of inactivity
2Min
Turns off display backlight after 2 minutes of inactivity
Always On
Display backlight always on
Key Lock
On
Locks display (password is
<UP>
,
<DOWN>
,
<UP>
,
<DOWN>
,
<ENTER>
)
Off
Information
Fixture Hours
<_ _ _ _H>
Shows total hours the product has been powered on
Version
<V_._>
Shows current firmware version
UID
<_ _ _ _ _ _>
Shows product UID
Factory Reset
No
Resets the product to factory default settings
Yes
Main Level
Programming Levels
Description