Page 5 of 44
Rogue R2X Wash VW User Manual Rev. 3
Setup
3. Setup
AC Power
The Rogue R2X Wash VW has an auto-ranging power supply and it can work with an input voltage range
of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current
value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
The listed current rating indicates the product’s average current draw under normal conditions.
AC Plug
The Rogue R2X Wash VW comes with a power input cable terminated with a Neutrik
®
powerCON
®
A
connector on one end and an Edison plug on the other end (U.S. market). If the power input cable that
came with your product has no plug, or if you need the change the plug, use the table below to wire the
new plug.
Power Linking
The product supports power linking of up to 3 Rogue R2X Wash VW products at 100 V, up to 4 products at
120 V, up to 7 products at 208, or up to 8 products at 230 or 240 V. This product comes with a power input
cable. Power-linking cables are available for purchase from Chauvet.
Fuse Replacement
1.
Disconnect this product from the power outlet.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove the blown fuse and replace with another fuse of the same type and rating (F 5 A, 250 V).
4.
Screw the fuse holder cap back in place and reconnect power.
Remote Device Management (RDM)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate
bi-directionally along existing DMX cabling. Check the DMX controller’s User Manual or with the
manufacturer as not all DMX controllers have this capability. The Rogue R2X Wash VW supports RDM
protocol that allows feedback to make changes to menu map options.
•
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure
the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
•
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green