AC Power 

The SlimPAR H6 USB has an auto-ranging power supply and it can work with an input 
voltage range of 100  to  240 VAC, 50/60 Hz.  To determine the  product’s  power 
requirements  (circuit breaker, power outlet, and wiring), use the current value listed on 
the label affixed to the product’s back panel, or refer to the product’s specifications chart. 
The listed current rating indicates the product’s average current draw under normal 
conditions. 

 

 

Always connect the product to a protected circuit (circuit breaker or fuse). 
Make sure the product has an appropriate electrical ground to avoid the risk 
of electrocution or fire. 

 

To eliminate unnecessary wear and improve its lifespan, during periods of 
non-use completely disconnect the product from power via breaker or by 
unplugging it. 

 

Never connect the product to a rheostat (variable resistor) or dimmer circuit, even 
if the rheostat or dimmer channel serves only as a 0 to 100% switch. 

Fuse 

Replacement 

1.  Wedge the tip of a flat-head screwdriver into the slot of the fuse holder. 
2.  Pry the fuse holder out of the housing. 
3.  Remove the blown fuse from the holder and replace with a fuse of the exact same 

type and rating. 

4.  Insert the fuse holder back in place and reconnect power. 

 

 
 
 
 
 
 
 
 
 
 

 

Disconnect the product from the power outlet before replacing the fuse. 

Power Linking

 

The  product  provides power linking via the Edison  outlet located in the back of the 
product. Please see the diagram below for further explanation. 

Power Linking 

Diagram 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

You can power link up to 20  SlimPAR  H6  USB  products on 120 VAC or up to 39 
SlimPAR H6 USB products on 230 VAC. 

 

The power linking diagram corresponds to the North American version of the 
product  ONLY! If using the  product  in other markets, you must consult with the 
local  Chauvet  distributor as power linking connectors and requirements may 
differ in your country or region. 

 

 

Spare fuse holder 

(inside safety cap) 

Installed fuse  

(held by plastic clip) 

Safety cap 

1

st

 Product 

2

nd

 Product 

3

rd

 Product 

Additional 

Products 

All manuals and user guides at all-guides.com

Содержание SlimPAR H6

Страница 1: ...User Manual All manuals and user guides at all guides com ...

Страница 2: ... 9 DMX Linking 10 Configuration DMX 10 D Fi USB Connectivity 10 Configuration D Fi USB 10 DMX Personality and Starting Address 11 DMX Channel Assignments and Values 11 12CH 11 8 CH 12 6 CH 12 Configuration Standalone 13 Automatic Programs 13 Auto Program Speed 13 Sound Active Mode 13 Sound Sensitivity 13 Preset Color Mode 13 Custom Color Mixing 13 Dimmer Speed 13 IRC 6 Infrared Remote Control 14 I...

Страница 3: ... instructions may make the product not work cause damage to the product or cause harm to the operator Important installation or configuration information The product may not function correctly if this information is not used Useful information Disclaimer Chauvet believes that the information contained in this manual is accurate in all respects However Chauvet assumes no responsibility and specific...

Страница 4: ... the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots on the product ...

Страница 5: ...ug anything other than a D Fi USB into the USB port Doing so may cause damage to the product DMX In Out Power In Microphone D Fi USB Port Power Out Safety Cable Pass Through Fuse Holder Display Menu Buttons Back Panel View Front View Lenses IR Sensor All manuals and user guides at all guides com ...

Страница 6: ...Page 6 of 19 SlimPAR H6 USB User Manual Rev 1 Product Dimensions 9 6 in 244 mm 3 6 in 92 mm 8 3 in 211 mm All manuals and user guides at all guides com ...

Страница 7: ...nnel serves only as a 0 to 100 switch Fuse Replacement 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse holder out of the housing 3 Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating 4 Insert the fuse holder back in place and reconnect power Disconnect the product from the power outlet before replacing the fuse ...

Страница 8: ...ications for weight information When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple products mount the products close enough for power linking cables to reach The bracket adjustment knobs...

Страница 9: ...ed value Menu Map Main Level Programming Levels Description 6 CH d001 512 6 channel DMX mode 8 CH d001 512 8 channel DMX mode 12CH d001 512 12 channel DMX mode C C1 63 Static colors P automatic P1 6 color program snap P2 6 color program pulse P3 32 color program snap P4 32 color program fading S S 1 100 Program speed for P1 P4 Snd sound active Snd1 6 color program sound active Snd2 32 color progra...

Страница 10: ...duct s DMX Personality and DMX Address set the DIP switch D Fi receiving transmitting channel then plug it into the D Fi USB port WARNING DO NOT plug anything other than a D Fi USB into the USB port Doing so may cause damage to the product Once plugged in the D Fi USB will take over the product Wired DMX manual display control menu buttons and IRC will be unavailable until you unplug the D Fi USB ...

Страница 11: ...s and Values 12CH Channel Function Value Percent Setting 1 Dimmer 000 ó 255 0 100 2 Red 000 ó 255 0 100 3 Green 000 ó 255 0 100 4 Blue 000 ó 255 0 100 5 Amber 000 ó 255 0 100 6 White 000 ó 255 0 100 7 UV 000 ó 255 0 100 8 Strobe 000 ó 010 No function 011 ó 255 Strobe slow to fast 9 Color Macros Overrides Ch 2 7 000 ó 015 No function 016 ó 255 Color macros 10 Mode 000 ó 010 No function 011 ó 050 Au...

Страница 12: ...00 ó 255 0 100 5 Amber 000 ó 255 0 100 6 White 000 ó 255 0 100 7 UV 000 ó 255 0 100 8 Strobe 000 ó 010 No function 011 ó 255 Strobe slow to fast 6 CH Channel Function Value Percent Setting 1 Red 000 ó 255 0 100 2 Green 000 ó 255 0 100 3 Blue 000 ó 255 0 100 4 Amber 000 ó 255 0 100 5 White 000 ó 255 0 100 6 UV 000 ó 255 0 100 All manuals and user guides at all guides com ...

Страница 13: ...s ENTER The product will only respond to low frequencies of music bass and drums Sound Sensitivity To change the sound sensitivity on the SlimPAR H6 USB follow the instructions below 1 Press MENU repeatedly until SenS shows on the display 2 Use UP and DOWN to increase or decrease the sound sensitivity u 0 100 3 Press ENTER The product will return to the last selected mode Preset Color Mode To run ...

Страница 14: ...ess or to increase or decrease the sound sensitivity Manual Color Control To choose a specific color with the IRC 6 1 Press MANUAL on the IRC 6 2 Press any number between 0 9 to choose your color To manually control the RGB percentage 1 Press MANUAL on the IRC 6 2 Press R red G green B blue A amber UV P UV or W white to choose your color 3 Press or to increase or decrease the percentage of each co...

Страница 15: ...nnect more than 31 slaves to the master Master Slave Mode D Fi USB The D Fi USB allows a single SlimPAR H6 USB product the master to control the actions of one or more SlimPAR H6 USB products the slaves without the need of a DMX controller or DMX cables The master transmitter product will be set to operate in either Stand Alone mode or with the IRC 6 while the slave receiver products will be set t...

Страница 16: ...follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free cotton cloth or a lens c...

Страница 17: ...ducts 8 A 20 products 8 A 39 products Fuse T 1 A 250 V T 1 A 250 V Power I O U S Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S Local plug Light Source Type Power Lifespan LED 10 W 50 000 hours Color Quantity Current Hex color RGBAW UV 6 2 4 A Photometrics Parameter Value Strobe Rate 0 to 18 Hz Beam Angle 23 Field Angle 41 Illuminance...

Страница 18: ...t a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return Send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet will refuse any product returned wit...

Страница 19: ...w chauvetlighting eu General Information Chauvet Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO General Information Chauvet Mexico Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexico C P 52000 Voice 52 72...

Отзывы: