Geyser P7 QRG Rev. 2
Mounting
Before mounting this product, read the
. Use at least 2 mounting points per product.
Inverting the Tank
To prevent leaking or spilling, always position the fluid tank with its cap in the uppermost position, above the fog fluid line.
When mounting the Geyser P7 overhead, invert the fluid tank by doing the following:
1.
Detach the removable shield by removing the thumb-screw.
2.
Pull the fluid tank out and set it on a flat surface.
3.
Detach the fluid tank plate by removing 4 screws.
4.
Secure the fluid tank plate to the opposite side with the 4 screws.
5.
Insert the fluid tank.
6.
Secure the removable shield by inserting the end without the thumbscrew into the slot, and screwing in the
thumbscrew.
Mounting Diagram
•
To prevent leaking or spilling, always position the fluid tank with its cap in the uppermost
position, above the fog fluid line.
•
Do not fill the fluid tank to the cap when mounted horizontally.
Fluid Tank Plate
Screws (x4)
Omega Bracket Placement Options
Omega Bracket (x2)
Safety Cable
Safety Cable
Mounting Clamp (x2)
Upwards Fog Output
Downwards Fog Output
Horizontal Fog Output
Omega Bracket (x2)
Omega Bracket (x2)
Mounting Clamp (x2)
Mounting Clamp (x2)
Surface Mounting