Chart Inc.

407 7th Street NW 
New Prague, MN 56071 USA 
(800) 400-4683

Product Manual

APPS-160

Содержание APPS-160

Страница 1: ...Part Number 11929931 Rev B 2014 Chart Inc Designed and Built by Chart Inc 407 7th Street NW New Prague MN 56071 USA 800 400 4683 Product Manual APPS 160...

Страница 2: ......

Страница 3: ...al 1 Terms 1 Acronyms Abbreviations 2 Safety 3 General 3 Nitrogen and Argon 4 Installation Operation 5 Installation 5 Start Up 5 Operation 5 Adjustments 6 Operating Pressure 6 Liquid Nitrogen Level 6...

Страница 4: ...iv Table of Contents Product Manual APPS 160 Revision Log Revision Level Date Description B 07 25 2014 Convert to new layout and combine with manual PN 13428250 for 220V...

Страница 5: ...e control on liquid use Mini bulk storage for under sized vacuum lines Low cost alternative to two bulk tanks Two operating pressure ranges available Stainless steel plumbing Product Manual The APPS 1...

Страница 6: ...onyms abbreviations are used throughout this manual APPS 160 Adjustable Pressure Phase Separator dB Decibel GPM Gallons per minute Hz Hertz MAWP Maximum Allowable Working Pressure OD Outer Dimension P...

Страница 7: ...posed to an atmosphere containing only 8 to 12 oxygen In this environment unconsciousness can be immediate with virtually no warning When the oxygen content of air is reduced to about 15 to 16 the fla...

Страница 8: ...r sustain life Inhalation of high concentrations of these gases can cause anoxia resulting in dizziness nausea vomiting or unconsciousness and possibly death Individuals should be prohibited from ente...

Страница 9: ...properly installed The APPS 160 unit should be purged with warm dry nitrogen gas prior to introducing liquid to ensure that the unit does not have moisture in the inner vessel Turn APPS unit power swi...

Страница 10: ...ution To monitor adjustment power must be on and wires will be powered or hot Turn large brass hex nut In or clockwise will decrease set point Out or counterclockwise will increase set point Replace c...

Страница 11: ...valve or over tightened valve bolts The bolts should not be tighter than 12 foot pounds and should be evenly torqued If the gasket between the bodies leaks it needs to be replaced Mark the location of...

Страница 12: ...8 Product Manual APPS 160...

Страница 13: ...ction 1 2 male 45 flare 1 2 male 45 flare 1 2 male 45 flare 1 2 male 45 flare Outlet connection 1 female MVE bayonet 1 female MVE bayonet 1 female MVE bayonet 1 female MVE bayonet Vent connection 1 2...

Страница 14: ...Vessel PRV 100 psig 11915572 11915572 11915572 11915572 Vessel SRV 150 psig 11915581 11915581 11915581 11915581 Inlet piping RV 235 psig 1810062 1810062 1810062 1810062 Vent regulator 11756911 211058...

Страница 15: ...11 Specifications Product Manual APPS 160 Inlet Check Valve Inlet Strainer Inlet Connection Control Box On Off Switch Fill Valve Indicator Light Vent Valve Indicator Light...

Страница 16: ...ions Product Manual APPS 160 Control Box hot black wire connection Control Box neutral white wire connection Control Box ground green wire connection Liquid Level switch connections Liquid Level switc...

Страница 17: ...13 Specifications Product Manual APPS 160 Pressure switch connections Pressure switch adjustments Control Box Electrical Schematic...