background image

®

charnwood

T:+44  (0)1983  537799  •  F:+44  (0)1983  537788  •  [email protected]  •  WWW.CHARNWOOD.COM 

  BISHOPS  WAY,  NEWPORT,  ISLE  OF  WIGHT    PO30  5WS,  UNITED  KINGDOM

 

Issue B

 

ISLAND III  (cz) 

 PARTS LIST

®

charnwood

I

I S L A N D

III

II

* These items are not shown on the drawing.

# Please specify colour when ordering.

To obtain spare parts please contact your local stockist giving Model, Part Number 

and Description. In case of difficulty contact the manufacturer at the address 

shown.

This drawing is for identification purposes only.

Item

Part No

Description

Item

Part No

Description

1*

008/CY40S

Door Seal Set Inc. Adhesive

33

004/BX048

Tool Holder

2*

008/FW29

Door Seal Adhesive

34

002/PX89

Riddler Knob

3

002/CG20

Bottom Grate Bar

35

004/CY21

Air Bypass Slide

4

002/CG20S16

Set of Grate Bars (16)

36

004/CY22P

Primary Air Inlet Flap

5

010/CY14L

Side Fire Plate L.H.

37

004/CY22S

Secondary Air Inlet Flap

6

010/CY14R

Side Fire Plate R.H.

38

004/AY22-1S

Secondary/Bypass Air Inlet Flap

7

010/CY16

Back Fire Plate

39

004/CY24

Flap Mounting Rod (Inc. Fixings)

8

006/CY18

Glass (Inc Seal)

40

004/CY32

Air Control Rod

9*

008/CY41

Glass Seal 

41

004/CY23

Actuator Assembly

10

004/KV23

Glass Retainer

42

008/CY39

Upper Quattro Box Gasket

11

011/CY29S

Set of Fire Bricks (4)

43

010/CY20

Upper Quattro Box

12

004/XV30

Brick Retainer

44

010/CY19

Lower Quattro Box

13

010/CY31

Throat Plate

45#

002/CY01/A

Left Hand Door Assembly

14

008/CY26S

Set of Air Inlet Flap Pads

46#

002/CY02/A

Right Hand Door Assembly

15

012/CY33

Mover Bar

47

001/CZ010

Firebox (Island IIIZ)

16

002/CY30

Carrier Bar

48

010/CY37

Blanking Plate

17

012/AY13

Idler Rod

49

010/CY61

Clamping Plate

18

012/AY15

Riddler Rod 

50

002/CY45

Flue Collar

19

004/CX17L

Ashpan L.H.

51

008/CY38

Flue Fixing Rope Seal

20

004/CX17R

Ashpan R.H.

52

012/CZ011

Serial No. Label

21

002/CY07C

Front Firebar

53#

010/CY34

Vert. Rear Flue Connector (Opt'l Extra)

22

002/CY08C

Deepening Bar

54*

010/BW51

Ash Carrier (Optional Extra)

23

008/KV16

R.H. Door Handle

55*

010/CY83

Smoke Reducing Kit

24

002/AY14

Door Catch Cam

56

010/CY52A

External Air Manifold Kit

25

008/FFW015

M12 Double Coil spring Washer

57#

005/CX093L

LH Curved Panel (Opt'l Extra)

26

004/ST008

Tabbed Locking Washer

58#

0045/CX093R

RH Curved Panel (Opt'l Extra)

27

008/FFN001

M12 Half Nut

59

010/AX096

Panel Fixing Bracket

28

008/KV13

L.H. Door Knob

60#

010/CX080

Heatshield (Opt'l Extra)

29

008/BW39/S

Hinge Pin Set

61#

010/CY12S

Set of Low Legs (4)

30

002/PY24

Hinge Post

62#

010/CY64S

Set of High Legs (4)

31

008/AY37

Air Control Knob

63#

010/CY87

Store Stand

32

008/PX95

Riddling/Ashpan Tool

22

21

16

34

6

18

7

19

20

45

23

25

24

26

27

8

10

 62

 63

11

12

13

11

58

48

51

49

50

53

 60

56

57

47

 61

 59

42

43

38

37

36

41

40

31

35

39

44

3

4

15

17

33

32

30

52

5

28

29

37 14

46

16

11/11/2024- Updated parts lists to Issue B

Содержание Island

Страница 1: ...Operating Installation Instructions charnwood I I S L A N D III II Version AZ BZ CZ ...

Страница 2: ......

Страница 3: ...LLATION INSTRUCTIONS Health Safety Precautions 8 Specification 8 Chimney 8 Hearth Fire Surround 9 Island I Dimensions 11 Riddling 3 Controlling The Fire 3 Ash Clearance 3 Lighting 4 CO Alarms 8 Connection to Flues 9 Soot Doors 10 Pre Lighting Check 10 Commissioning 10 Island II Dimensions 12 Parts Lists 14 16 Certification 17 Island III Dimensions 13 I I S L A N D III II Ref Island I II III z 06 1...

Страница 4: ...For the same reason hard woods such as Ash Beech and Oak are better than soft woods such as Pine and Spruce Burning wet unseasoned wood will also result in considerably reduced outputs The wood should be cut and split and then left to season in a well ventilated dry place for at least one year but preferably two years before use PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE ITS USE WILL...

Страница 5: ... the tool should be in the 1 o clock position for open grate or in the 5 o clock position for closed grate Patent No 2389414 Fig 2 Multifuel Grate OPERATING INSTRUCTIONS charnwood I I S L A N D III II CONTROLLING THE FIRE The fire is controlled by the single air control knob shown in Fig 3 Pull the knob out to make the fire burn faster push it in to make the fire burn slower TM This unique Quattro...

Страница 6: ... heat This is normal and will cease after a short time but meanwhile the room should be kept well ventilated At first only light a small fire and burn it slowly for two hours to allow any residual moisture in the bricks to evaporate Light the stove using dry kindling wood and paper or fire lighters Set the grate into the closed position Place the paper or fire lighters and kindling on the grate an...

Страница 7: ...ds as these can scratch the surface which will weaken the glass and cause premature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire When Not in Use If the fire is going to be out of use for a long period for instance in the summer then to prevent condensation and hence corrosion the air control should be left fully open and the fire doors left ajar It i...

Страница 8: ...ing keep the fuel as far back from the front firebar as possible do not try to fit too much fuel into the firebox c Wet wood or logs overhanging the front firebars will cause the glass to blacken d There is a bypass slide that can be adjusted to suit the particular installation This allows a small amount of airwash air to enter the stove even when the air control is closed This can be adjusted to ...

Страница 9: ...n the above action is taken then the fire brigade should be called immediately After a chimney fire the chimney should be carefully examined for any damage Expert advice should be sought if necessary IF YOU NEED FURTHER HELP If you need further help with your Charnwood Island then your Installer will be able to provide the answers to most questions Your Local Charnwood Premier Dealer has a great d...

Страница 10: ...y or ensuring regular servicing and maintenance of the appliance and chimney system CHIMNEY In order for the appliance to perform satisfactorily the chimney height must not be less than 4 metres measured vertically from the outlet of the stove to the top of the chimney For the Island 1 Island 2 the chimney must not be less than 150mm 6 inches internal diameter or 150 x 150mm internal square For th...

Страница 11: ...round the appliance to ensure that maximum heat is transferred to the room and also to prevent the fireplace from overheating A gap of 150mm 6 inches each side and 300mm 12 inches above the appliance should give sufficient air circulation If a wooden mantelpiece or beam is used in the fireplace it should be a minimum of 460mm 18 inches and preferably 600mm 24 inches from the appliance In some situ...

Страница 12: ...e bottom grate bars must all be fitted and should move freely and easilywhentheriddingmechanism isoperated 2 The plates round the sides and back of the grate must be in position andsittingcorrectly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The method of location andpositioningof thethroat plateisshowni...

Страница 13: ... Max dim with door open 601 Optional Vertical Rear Flue Adapter 88 410 132 163 465 143 634 565 579 99 355 439 155 Optional External Air Manifold 464 87 565 726 379 439 190 178 555 514 760 565 705 299 225 213 420 100 590 Flue outlet to suit 150mm 6 flue pipe ISLAND I DIMENSIONS mm charnwood I I S L A N D III II 11 ...

Страница 14: ...dim with door open 639 Optional Vertical Rear Flue Adapter 132 421 160 476 88 143 674 634 619 99 155 365 447 Optional External Air Manifold 87 504 765 634 710 875 634 820 584 447 190 393 48 179 595 301 295 289 451 120 705 Flue outlet to suit 150mm 6 flue pipe ISLAND II DIMENSIONS mm charnwood I I S L A N D III II 12 ...

Страница 15: ...W Max dim with doors open 705 Optional Vertical Rear Flue Adapter 105 452 533 171 147 186 713 765 763 732 108 845 765 795 750 945 995 714 484 196 400 484 428 190 400 48 335 309 Optional External air manifold 588 107 670 189 820 339 Flue outlet to suit 175mm 7 flue pipe ISLAND III DIMENSIONS mm charnwood I I S L A N D III II 13 ...

Страница 16: ...r 4 43 010 AY19 Lower Quattro Box 13 010 AY47 Throat Plate 44 002 AY01 A LH Door Assembly 14 008 AY26S Set of Air Inlet Flap Pads 45 002 AY02 A RH Door Assembly 15 012 AY33 Mover Bar 46 001 AZ010 Firebox Island I az 16 002 AY30 Carrier Bar 47 012 TW09 Blanking Plate 17 012 AY13 Idler Rod 48 010 AY51 Clamping Plate 18 012 AY15 Riddler Rod 49 002 CH12B Flue Collar 19 004 AX17 Ashpan 50 008 NV38 Flue...

Страница 17: ...0 Upper Quattro Box 12 004 XV30 Brick Retainer 43 010 AY19 Lower Quattro Box 13 008 AY26S Set of Air Inlet Flap Pads 44 002 BY01 A Left Hand Door Assembly 14 012 BY33 Mover Bar 45 002 BY02 A Right Hand Door Assembly 15 002 BY30 Carrier Bar 46 001 BZ010 Firebox Island IIZ 16 010 BY47 Throat Plate 47 012 TW09 Blanking Plate 17 012 AY13 Idler Rod 48 010 AY51 Clamping Plate 18 012 AY15 Riddler Rod 49 ...

Страница 18: ... Box 12 004 XV30 Brick Retainer 44 010 CY19 Lower Quattro Box 13 010 CY31 Throat Plate 45 002 CY01 A Left Hand Door Assembly 14 008 CY26S Set of Air Inlet Flap Pads 46 002 CY02 A Right Hand Door Assembly 15 012 CY33 Mover Bar 47 001 CZ010 Firebox Island IIIZ 16 002 CY30 Carrier Bar 48 010 CY37 Blanking Plate 17 012 AY13 Idler Rod 49 010 CY61 Clamping Plate 18 012 AY15 Riddler Rod 50 002 CY45 Flue ...

Страница 19: ...FICIENCY FUEL TYPES A Division of A J Wells Sons Limited Registered in England No 03809371 14 charnwood I S L A N D I III II Island I AZ50 CPD 2014 450mm 600mm 0 29 254 C 5 0kW 77 9 Wood Logs Island II BZ50 CPD 2014 450mm 600mm 0 50 290 C 8 0kW 78 0 Wood Logs Island III CZ44 CPD 2014 600mm 600mm 0 30 365 C 12 0kW 76 4 Wood Logs Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS SO...

Страница 20: ...e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r ISLAND I II III z 06 14 REV 1 ...

Отзывы: