background image

hot water system the unvalved radiator(s) on the gravity circuit must

have an output of at least 1.25 kW. This is to prevent boiling in case

of pump failure. All pipework in the primary circuit must be 28 mm

diameter and the gravity flow pipe must rise continuously from the

boiler to the open vent. Two typical systems are shown in Figures 5

and 6.

If the appliance is used to heat a small central heating system then the

heat output to the room from the fire will be reduced.

Fitting a radiator in the same room as the fire is recommended as it

will allow greater flexibility in the way that the system is operated as

well as ensuring that there is sufficient heat.

Connect the heating system to the boiler ensuring that the primary

flow pipe rises continuously from the appliance to the vent. Fill the

system with water and check for leaks.

The circulating pump may be controlled by means of time switches,

room thermostats or outdoor thermostats. Radiators may be either

manually or thermostatically controlled. These controls will all work

in conjunction with the thermostat on the appliance and the low limit

pipe thermostat.

We recommend fitting a pipe thermostat onto the gravity return to

act as a low limit thermostat This should be wired into the mains

supply to the pump so that if the gravity return temperature drops

below 45º C then the pump will cut out. This will help to prevent

condensation forming on the boiler faces and will thereby increase the

life of the boiler. It will also ensure that priority is given to the

SYSTEM CONTROLS

Register Plate
With Soot Door

Alternative

Soot Door Positions

Fig. 11. Horizontal Register Plate With Optional
Vertical Rear Flue Connector

197mm

Register Plate
With Soot Door

Alternative

Soot Door Positions

Fig. 10. Horizontal Register Plate With Top Flue Connection

Register Plate

With Soot Door

Alternative

Soot Door Positions

Fig. 9. Horizontal Register Plate With Rear Flue Connection

Register Plate

Soot Door

In Side or Rear

Of Chimney

Fig. 8. Vertical Register Plate With Bricked Up Fireplace

INSTALLATION  INSTRUCTIONS

®

charnwood

I S L A N D

11

Содержание Island III

Страница 1: ...Operating Installation Instructions I S L A N D charnwood ...

Страница 2: ......

Страница 3: ...e flueway cleaning Chimney Sweeping Trouble Shooting If you need any Further Help Health Safety Precautions Chimney Hearth Fire Surround Connection to Flues Soot Doors Thermostat Dimensions 4 4 4 5 5 5 5 5 6 6 6 6 7 8 9 9 9 12 12 12 13 INSTALLATION INSTRUCTIONS Lighting Central Heating System System Controls Pre Lighting Check Commissioning Parts Lists Certification 4 10 11 12 12 14 15 I S L A N D...

Страница 4: ... minimum effort If any operation such as riddling the grate or opening and closing the doors begins to require extra force then the cause must be investigated and corrected to prevent damage being caused to the stove Remember that the stove will be hot and is made from hard materials ensure that you have a good balance before operating the fire When using the stove in situations where children age...

Страница 5: ...ct with the underside of the grate as this will seriously damage the grate bars The ashpan is handled using the tool provided Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins To make ash removal easier there is a special Charnwood ash carrier available This may be purchased from your supplier or in case of difficulty from ourselves For correct firing w...

Страница 6: ... Cleaning Cleaning the Glass hob cleaner Some deposits on the glass may be burnt off simply by running the fire at a fast rate for a few minutes Do not use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire If the fire is going to be out of use for a ...

Страница 7: ...btained Keeping the glass clean requires a certain amount of experimentation due to the differences in the draw of different chimneys The following points should be noted and with a little care should enable the glass to be kept clean in most situations a The airwash relies on a supply of heated air to keep the glass clean therefore when lighting the stove allow the firebed to become well establis...

Страница 8: ...hat it is not distorted c the door seals are in good condition d If the hot water goes cold when the pump is turned on or if some radiators are hotter than others then the system may need balancing the pump may be pumping the water too quickly around the system Fire blazing out of control Over Firing Freezing Lack of Heat To Radiators Hot Water or the radiators may need bleeding Please ask your in...

Страница 9: ...he hearth must be at least 12mm 0 5inches thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state he chimney must not be less than 175 mm 7 inches internal diameter or 175 x 175mm internal square If an existing chimney is to be used it must be swept and checked it must be in good condition free from ...

Страница 10: ...d corrosion a suitable inhibitor should be used The system must be correctly vented as shown in Figs 5 and 6 The height differential between the header tank and the appliance must not exceed 15 2 metres 50 feet If all four boiler tappings are used then if possible diagonal pairs should be connected for domestic hot water and central heating Where a common return is used an injector tee must be inc...

Страница 11: ...Radiators may be either manually or thermostatically controlled These controls will all work in conjunction with the thermostat on the appliance and the low limit pipe thermostat We recommend fitting a pipe thermostat onto the gravity return to act as a low limit thermostat This should be wired into the mains supply to the pump so that if the gravity return temperature drops below 45º C then the p...

Страница 12: ...MOSTAT With the control knob at the minimum setting the flap should be just closed as shown in Fig 13 To adjust the distance slacken the locking nut and adjust as necessary When set correctly re tighten the locking nut Ensure that the flap opens and closes freely as the knob is turned and that the opening is completely covered when the flap is closed Beforeinitiallightingthefollowingpoints shouldb...

Страница 13: ...Flue Outlet To Suit 175mm 7 Flue Pipe 196 830 185 603 458 726 488 133 754 780 738 95 714 ISLAND IIIB DIMENSIONS charnwood I S L A N D 13 ...

Страница 14: ...DS29S Set of Fire Bricks 4 14 008 FW48 Thermostat 15 010 DS31 Throat Plate 16 010 DS32 Front Throatplate 17 012 CY33 Mover Bar 18 002 CY30 Carrier Bar 19 012 AY13 Idler Rod 20 012 AY15 Riddler Rod 21 004 CY17L Ashpan L H 22 004 CY17R Ashpan R H 23 002 CY07C Front Fence Island 3 24 008 KV16 R H Door Handle 25 002 AY14 Door Catch Cam 26 008 KV13 L H Door Knob 27 008 BW39 S Hinge Pin Set 4 per set 28...

Страница 15: ... WELLS SONS LTD EN13240 2001 ROOMHEATERS BOILER FIRED BY WOOD FUEL EC certificate of conformity no Maximum operating pressure Fuel types Minimum distance to combustible materials Side Rear Emission of CO in flue gases Flue gas temperature Space heating output Water heating output Energy efficiency DS50 CPD 2007 1 5 bar 200mm 120mm 0 67 354 C 9 0kW 9 0kW 73 3 Wood Logs ...

Страница 16: ... i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 44 0 1983 537777 F 44 0 1983 537788 CHARNWOOD AJWELLS CO UK WWW CHARNWOOD COM charnwood y o u r p re m i e r d e a l e r REV ISLAND IIIB 03 09 ...

Отзывы: