65

Charnwood Island II (BP-Australia) Parts List

Issue A

Item Part No.

Description

Item Part No.

Description

*These items are not shown on the drawing.
# Please specify colour when ordering.

To obtain spare parts please contact your local stockist giving Model, Part No. 
and Description. In case of difficulty contact the manufacturer at the address 
shown. This drawing is for identification purposes only.

1

008/BP035

Door Seal Set Inc. Adhesive

2*

008/FW29

Door Seal Adhesive

3

002/CG20

Grate Bar

4

002/CG20S12

Set of Grate Bars (12)

5

002/BU015L

LH Side Fire Plate

6

002/BU015R

RH Side Fire Plate

7

002/BP016

Back Fire Plate

8

010/BP039

LH Carrier Bar Support

9

010/AP040

RH Carrier Bar Support

10

010/BP033

Mover Bar

11

002/BY30

Carrier Bar

12

012/FW14

Idler Rod

13

010/BU077

Riddler Rod Assembly

14

002/AP098

Riddler Spigot

15

004/BP017

Ashpan

16

002/BP008

Deepening Bar

17

002/BP007

Front Fence (Lower)

18

004/BP052

Front Ash Shedding Plate

19

006/BP018

Glass

20

008/BP045

Glass Seal

21

004/KV23

Glass Retainer

22

011/BP029S

Set of Fire Bricks (4)

23

004/XV30

Brick Retainer (4)

24

011/BP031S

Set of Throatplate Bricks (2)

24a 010/BP077

Throat Plate Brick Hanger

25

010/BP032

Upper Throatplate

26

008/KV16

RH Door Handle

27

002/AY14

Door Catch Cam

28

008/FFW015

M12 Double Coil Spring Washer

29

004/ST008

Tabbed Locking Washer

30

008/FFN001

M12 Half Nut

31

008/KV13

LH Door Knob

32

008/ST068/4

Hinge Pin Set (4)

33# 002/AP024

Hinge Post

34

004/EZ095

Riddling/Ashpan Tool

35

004/AP051

Tool Holder

36

008/BP110

Air Control Gasket

37

010/BP111

Air Control Top Slider Plate

38

004/BP112

Wood/Multifuel Surround Plate

39

004/BP113

Wood/Multifuel Selection Slide

40

010/BP114

Air Control Lower Plate

41

008/KZ006

Air Box Gasket

42

004/BP115

Air Control Slider

43

004/BR015

Clicker Retainer Plate

44

008/ES36/01

Brass Ball Catch

45

004/EZ016

Control Rod

46

008/AY37

Air Control Knob

47

008/BR052

Felt Washer

48

004/KZ039

Air Box Cover

49

008/CR063

Duct Gasket

50

004/CR064

Blanking Plate

51

004/CR048

Air Inlet Spigot

52

008/FFS062

Defra Stop

53# 003/BP001A

LH Door Assembly

54# 003/BP002A

RH Door Assembly

55

001/BP010

Firebox (Island II BP)

56

012/TW09

Blanking Plate

57

010/AY51

Clamping Plate

58# 002/CH12B

Flue Collar

59* 008/NV38

Flue Fixing Rope Seal

60

012/BPA011

Serial No. Label

61

012/BPA180

Compliance Plate

62# 010/TW33

Vert. Rear Flue Connector (Opt'l Extra)

63* 010/EW51

Ash Carrier (Opt'l Extra)

64# 010/BP080

Heatshield

65

010//BPA170

Heatshield Extension

66# 010/BP012S

Set of Low Legs (Option)

67# 010/AY85S

Set of High Legs (Option)

68# 010/BP087

Store Stand (Option)

Содержание ISLAND II-BP

Страница 1: ... Operating Installation Instructions AUSTRALIA II BP ...

Страница 2: ......

Страница 3: ...HEALTH AND SAFETY PRECAUTIONS 10 FLUE 10 HEARTH AND FIRE SURROUND 10 CONNECTIONS TO FLUES 11 PRE LIGHTING CHECK 11 COMMISSIONING 11 COOKING PLATE 11 CLEARANCES 12 STANDARD HEARTH DIMENSIONS 13 CORNER HEARTH DIMENSIONS 14 FLUE CLEARANCES DIAGRAM 15 STANDARD DEFAULT TRIPLE SKIN FLUE KIT 16 INSULATED ROOM SEAL FLUE KIT 17 INSULATED ROOM SEAL FLUE KIT 18 INSULATED ROOM SEAL FLUE KIT 19 COMPLIANCE DATA...

Страница 4: ...indling and paper or firelighters Keep air control fully out and door cracked open Once kindling is alight add smaller logs Keep air control fully out and close door Add larger logs once fire is established Air control can be reduced to minimum MAINTENANCE AND CLEANING GLASS Wipe with damp lint free cloth Any stubborn deposits on the glass may be removed with a proprietary stove glass cleaner or c...

Страница 5: ...is not designed to burn household waste LIGHTING On initial lighting the stove may smoke and give off an odour as the silicon paint with which the firebox is painted reacts to the heat This is normal and will cease after a short time but meanwhile the room should be kept well ventilated At first only light a small fire and burn it slowly for two hours to allow any residual moisture in the flue to ...

Страница 6: ...t once or twice a week Fig 2 Operating the wood ash removal grate RIDDLING When burning wood ash should be allowed to build up and only riddled when the ash begins to cover the rear fireplate The fire should be riddled with the door shut see Fig 2 Place the operating tool onto the riddling lever and rotate between the open and closed positions several times Too much riddling can result in emptying...

Страница 7: ...n open the door and allow it to cool Clean the glass using a damp cloth and then wiping over with a dry cloth Any stubborn deposits on the glass may be removed with a proprietary stove glass cleaner or ceramic hob cleaner Do not use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure When Not in Use If the fire is going to be out of us...

Страница 8: ...ues the manufacturers instructions with regard to sweeping should be consulted TROUBLE SHOOTING Fire Will Not Burn Check that a the air inlet is not obstructed in any way b flues and flue are clear c a suitable fuel is being used d there is an adequate air supply into the room e If an extractor fan is fitted that it is not causing lack of flue draft when operating f there is sufficient draw in the...

Страница 9: ...door is tightly closed b The air control slider is fully closed c A suitable fuel is being used d Door seals and air slide are intact Flue Fires If the flue is thoroughly and regularly swept flue fires should not occur However if a flue fire does occur close the air control and tightly close the door of the appliance This should cause the flue fire to go out in which case the controls should be ke...

Страница 10: ...ust give sufficient draw when warm minimum of 12pa 0 05 wg The height of the flue must comply with local building regulation requirements The internal dimensions of the flue MUST NOT BE LESS THAN 150mm 6 The listed flue s construction and installation must comply with the requirements of AS NZS2918 2018 and must also meet local building codes The flue must be suitable for burning solid fuel lined ...

Страница 11: ... the appliance For location and positioning see Fig 5 Check that the front fence is fitted correctly and that the door closes properly COMMISSIONING Ensure that the rear heatshield extension is fitted to the back of the heaishield part 010 BPA170 with 2 x 12mm self tapping screws This part must be supplied and fitted to the stove On completion of the installation allow a suitable period of time fo...

Страница 12: ...12 CLEARANCES A A B A B C D PARALLEL POSITION COMBUSTIBLE WALLS CORNER POSITION Standard Clearance A 225mm B 385mm C 450mm D 757mm ISLAND II BP Corner Clearance A 275mm B 578mm ...

Страница 13: ...875mm C 470mm D 275mm E 225mm TO WALL MIN DIMENSIONS TO WALL A 1158mm B 875mm C 470mm D 275mm E 458mm VERTICAL REAR FLUE ADAPTOR VERTICAL REAR FLUE ADAPTOR ISLAND II BP NON COMBUSTIBLE MATERIAL Minimum thickness 24mm Minimum thermal resistivity 0 052m2 K W Installed in accordance with AS NZS 2918 2018 3 3 2 B C D D A B E C D D A B E C D D A ...

Страница 14: ...REAR FLUE ADAPTOR CORNER HEARTH A 875mm B 578mm C 470mm WITH VERTICAL REAR FLUE ADAPTOR A 875mm B 578mm C 470mm D 458mm ISLAND II BP C A B B B B C D D A NON COMBUSTIBLE MATERIAL Minimum thickness 24mm Minimum thermal resistivity 0 052m2 K W Installed in accordance with AS NZS 2918 2018 3 3 2 ...

Страница 15: ... top Increase from 1000 min until clear within 3000 of flue top DIMENSIONS IN MILLIMETRES Summary of minimum height of flue sytem exit requirements from AS NZS 2918 2018 More than 3000 More than 3000 600 min 600 min 3000 Any nearby structure Increase as necessary until nothing within 6000 of flue top ...

Страница 16: ...16 150 1000 1000 1000 1000 25 600 Cowl Triple skin flue Flashing Optional Decorative Flue Solid OR Mesh Ceiling Ring Dropbox STANDARD DEFAULT TRIPLE SKIN FLUE KIT ...

Страница 17: ...17 INSULATED ROOM SEAL FLUE KIT 185 1000 1000 1000 25 50 Single skin flue Room sealed flue adaptor Ceiling ring Heatshield Starter length flue Cowl Room sealed flue with locking band STANDARD FLUE KIT ...

Страница 18: ...18 INSULATED ROOM SEAL FLUE KIT FULLY SEALED FLUE KIT 1000 1000 1000 1000 25 50 Cowl Ceiling ring Heatshield Starter length flue Room sealed flue with locking band ...

Страница 19: ...mm clearance to any timber to the side and underneath Min 470 Max 620 Cowl Adjustable wall bracket Cleaning access Wall Plate INSULATED ROOM SEAL FLUE KIT REAR FLUE KIT Room sealed flue with locking band Room sealed flue with locking band Room sealed flue adaptor 90 degree tee with cap Wall plate gal Ceiling ring Roof support brace ...

Страница 20: ...20 COMPLIANCE DATA ISLAND II BP COMPLIANCE DATA Compliance plate riveted onto rear heatshield ...

Страница 21: ...EG HIGH LEG STORE STAND FRONT SIDE REAR PLAN VIEW Optional rear flue adaptor To suit 150mm 6 flue pipe 160 134 160 418 482 96 614 728 675 105 602 366 160 448 79 76 560 66 621 813 760 584 795 848 299 225 80 186 680 392 330 190 151 645 ...

Страница 22: ...r 4 24 011 BP031S Set of Throatplate Bricks 2 24a 010 BP077 Throat Plate Brick Hanger 25 010 BP032 Upper Throatplate 26 008 KV16 RH Door Handle 27 002 AY14 Door Catch Cam 28 008 FFW015 M12 Double Coil Spring Washer 29 004 ST008 Tabbed Locking Washer 30 008 FFN001 M12 Half Nut 31 008 KV13 LH Door Knob 32 008 ST068 4 Hinge Pin Set 4 33 002 AP024 Hinge Post 34 004 EZ095 Riddling Ashpan Tool 35 004 AP...

Страница 23: ...and must be accompanied by proof of purchase Nothing in this guarantee shall affect your statutory rights EXCLUSIONS AND LIMITATIONS This Guarantee does not cover the following Charnwood will not be liable for any consequential loss or incidental loss damage or injury however caused This guarantee will become void if the appliance is not installed by a suitably qualified and is not installed in ac...

Страница 24: ...your premier dealer ...

Отзывы: