background image

Operating & Installation Instructions 

charnwood

I

I S L A N D

III

II

®

Содержание Island 1

Страница 1: ...Operating Installation Instructions charnwood I I S L A N D III II ...

Страница 2: ......

Страница 3: ...g 6 Trouble Shooting 7 If you need Further help 8 INSTALLATION INSTRUCTIONS Health Safety Precautions 9 Specification 9 Chimney 9 Hearth Fire Surround 10 Island I Dimensions 12 Lighting 5 Connection to Flues 10 Soot Doors 11 Pre Lighting Check 11 Commissioning 11 Island II Dimensions 13 Island III Dimensions 14 Parts Lists 15 17 Certification 18 I I S L A N D III II Ref Island I II III 06 13 Issue...

Страница 4: ...reguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 Do not use an aerosol spray on or near the stove when it is alight There is a risk of explosion or flash ignition of the spray FUEL This stove is intended primarily for burning wood Only dry well seasoned wood should be burnt on this appliance as burning wet unseas...

Страница 5: ...o evaporate When relighting the stove riddle slightly and then empty the ashpan CONTROLLING THE FIRE The fire is controlled by the single air control knob shown in Fig 1 Pull the knob out to make the fire burn faster push it in to make the fire burn slower TM This unique QuattroFlow air control provides carefully balanced primary secondary tertiary and bypass air to enable optimum burning conditio...

Страница 6: ...ng well After long periods where the fire has been out of use the chimney and appliance flueways should be cleaned before lighting Door Seals For the fire to operate correctly it is important that the door seals are in good condition Check that they do not become worn or frayed and replace them when necessary Servicing It is recommended that the fire is serviced once a year to keep it in first cla...

Страница 7: ... airwash air to enter the stove even when the air control is closed This can be adjusted to help with keeping the glass clean when the fire is slumbering It is always more difficult to keep the glass clean when running the stove very slowly for long periods Check that all flue connections and the blanking plate are well sealed It is also important that the chimney draw is sufficient when the chimn...

Страница 8: ...mney and flueways should then be cleaned If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately After a chimney fire the chimney should be carefully examined for any damage Expert advice should be sought if necessary IF YOU NEED FURTHER HELP If you need further help with your Charnwood Island then your Installer will be able to provide...

Страница 9: ... in which the appliance is installed to provide combustion air The has 5kW output and therefore a permanent air vent is not normally required The combustion air supply for Island 2 3 must be via a 2 permanently open vent Minimum free areas are 16 5cm 2 2 2 2 5 in 38 5cm 6 in 150 x 150mm internal square For the Island 3 be less than 175mm 7 inches internal diameter or 175 x 175mm internal square If...

Страница 10: ...antelpiece to protect it In order for the fire to operate correctly there must be an air gap behind the appliance of at least 40mm but be aware that this distance will need to be greater in some cases to meet Building Regulation requirements CONNECTIONS TO FLUES There are several ways of connecting the stove to the flue These are illustrated in figures 4 to 7 If a top flue connection as shown in F...

Страница 11: ... The bottom grate bars must all be fitted and should move freely and easilywhentheriddlingmechanism isoperated 2 The plates round the sides and back of the grate must be in position andsittingcorrectly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The method of location andpositioningof thethroat plateissh...

Страница 12: ...W BACK VIEW TOP VIEW 533 670 551 331 Max dim with door open 601 Optional Vertical Rear Flue Adapter 88 410 132 163 465 143 634 554 579 99 355 439 155 Optional External Air Manifold 464 87 554 726 379 439 190 178 555 514 760 554 705 299 225 213 420 100 590 Flue outlet to suit 150mm 6 flue pipe ISLAND I DIMENSIONS ...

Страница 13: ... BACK VIEW TOP VIEW 605 622 331 Max dim with door open 639 Optional Vertical Rear Flue Adapter 132 421 160 476 88 143 674 624 619 99 155 365 447 Optional External Air Manifold 87 504 765 624 710 875 624 820 584 447 190 393 48 179 595 301 295 289 451 120 705 Flue outlet to suit 150mm 6 flue pipe ISLAND II DIMENSIONS ...

Страница 14: ...S L A N D charnwood FRONT VIEW SIDE VIEW BACK VIEW HIGH LEG STORE STAND STANDARD LEG TOP VIEW Max dim with doors open 705 Optional Vertical Rear Flue Adapter 105 452 533 171 147 186 713 754 763 732 108 845 754 795 750 945 995 714 484 196 400 484 428 190 400 48 335 309 Optional External air manifold 588 107 670 189 820 339 Flue outlet to suit 175mm 7 flue pipe ...

Страница 15: ...and I 19 002 AY30 Carrier Bar 44 012 TW09 Blanking Plate 20 012 AY13 Idler Rod 45 010 AY51 Clamping Plate 21 012 AY15 Riddler Rod 46 002 CH12B Flue Collar 22 004 AY17 Ashpan 47 008 NV38 Flue Fixing Rope Seal 23 002 AY07B Front Firebar 48 012 AY11 Serial No Label 23a 002 AY08 Deepening Bar 49 010 TW33 Vert Rear Flue Connector Opt l Extra 24 008 KV16 R H Door Handle 50 010 EW51 Ash Carrier Optional ...

Страница 16: ...e 19 002 BY30 Carrier Bar 45 010 AY51 Clamping Plate 20 012 AY13 Idler Rod 46 002 CH12B Flue Collar 21 012 AY15 Riddler Rod 47 008 NV38 Flue Fixing Rope Seal 22 004 BY17 Ashpan 48 012 BY11 Serial No Label 23 002 BY07B Front Firebar 49 010 TW33 Vert Rear Flue Connector Opt l Extra 23a 002 BY08 Deepening Bar 50 010 BW51 Ash Carrier Optional Extra 24 008 KV16 R H Door Handle 51 010 BY83 Smoke Reducin...

Страница 17: ...ler Rod 44 001 CY10 Firebox Island III 21 004 CY17L Ashpan L H 45 010 CY37 Blanking Plate 22 004 CY17R Ashpan R H 46 010 CY61 Clamping Plate 23 002 CY07C Front Firebar 47 002 CY45 Flue Collar 23a 002 CY08C Deepening Bar 48 008 CY38 Flue Fixing Rope Seal 24 008 KV16 R H Door Handle 49 012 CY11 Serial No Label 25 002 AY14 Door Catch Cam 50 010 CY34 Vert Rear Flue Connector Opt l Extra 26 008 KV13 L ...

Страница 18: ... EFFICIENCY FUEL TYPES A Division of A J Wells Sons Limited Registered in England No 03809371 10 charnwood I S L A N D I III II Island I AY50 CPD 2010 450mm 600mm 0 29 254 C 5 0kW 77 9 Wood Logs Island II BY50 CPD 2006 450mm 600mm 0 50 290 C 8 0kW 78 0 Wood Logs Island III CY44 CPD 2006 600mm 600mm 0 30 365 C 12 0kW 76 4 Wood Logs Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS...

Страница 19: ......

Страница 20: ...d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r REF ISLAND I II III 06 13 ISSUE L ...

Отзывы: