background image

that it begins to block the passage of
air into the firebox at the side of the
grate. When this is the case do not
remove all of the ash using the
riddling mechanism but keep a layer
about half an inch thick as this
enables the wood to burn more
effectively. When burning wood or
peat use the airwash control in the
same way as described (see
"CONTROLLING THE FIRE" )but
keep the door airslides closed once
the desired temperature has been
reached.

OVERNIGHT

BURNING

For overnight burning the fire doors
must be closed.

When burning solid fuel the ashpan
should be emptied and the fire
riddled. The air controls should be
turned up to maximum for a brief
period and then when the fire is
burning brightly it should be loaded
with fuel. When the new fuel has
ignited, the door airslides should be
almost closed and the airwash control
moved to a low setting. Some
experimentation will be necessary to
find the settings most suitable for the
particular fuel used and the draw on
the chimney. To revive the fire,
empty the ashpan, riddle, and open
the air controls to maximum. When
the fire is burning well load on more
fuel as necessary and move the air
controls to the desired setting.

When burning wood use large logs
rather than small ones. Proceed as
above, but do not riddle the fire
either when shutting down or
reviving.

MAINTENANCE

Cleaning

The stove is finished with a high
temperature paint which will
withstand the temperatures
encountered in normal use. This may
be cleaned with a damp lint-free cloth
when the stove is cold. Should
re-painting become necessary, high
temperature paints are available from
your supplier or from stove shops.

Cleaning the Glass

The glass in the doors is a special
ceramic glass which is able to

withstand high temperatures. Before
cleaning the glass open the doors and
allow them to cool. Clean the glass
using a damp cloth and then wiping
over with a dry cloth. Any stubborn
deposits on the glass may be removed
with a proprietary stove glass cleaner
or ceramic hob cleaner. Some
deposits on the glass may be burnt off
simply by running the fire at a fast
rate for a few minutes. Do not use

abrasive cleaners or pads as these can
scratch the surface which will weaken
the glass and cause premature failure.
Aerosol spray cleaners should not be
used near the appliance whilst it is
under fire.

When not in use

If the fire is going to be out of use for
a long period, (for instance in the
summer,) then to prevent condensa-
tion, and hence corrosion, the
thermostat should be left at the
maximum setting and the main doors

left ajar. It is also advisable to sweep
the chimney and clean out the fire.
Spraying the inside of the doors and
firebox with a light oil, such as
WD40, will also help to keep all
internal parts working well.

After long periods where the fire has
been out of use, the chimney and
appliance flueways should be cleaned
before lighting.

Door Seals

For the fire to operate correctly it is
important that the door seals are in
good condition. Check that they do
not become worn or frayed and
replace them when necessary.

Servicing

It is recommended that the fire is
serviced once a year to keep it in first
class working order. After cleaning
out the firebox thoroughly, check that
all internal parts are in good working
order, replacing any parts that are
beginning to show signs of wear.
Check that the doors seals are in
good condition and that the doors
seal correctly. A servicing guide is
available on request.

THROAT PLATE AND

FLUEWAY CLEANING

It is important that the throat plate
and all the stove flueways are kept
clean. When burning smokeless fuels
they should be cleaned monthly.
When burning other fuels they should
be cleaned at least once a week, and
more frequently if necessary. It is not
necessary to let the fire out
completely to carry out these
operations.

The throat plate is lowered using the
tool. The front of the throat plate is
pulled forward and then lowered as
shown in figure 3. Any sooty deposits
should then be swept from the plate
and into the fire.

Return the throat plate to its correct
position - raise the front of the plate,
push it back and then lower it onto
the retaining lugs.

CHIMNEY SWEEPING

The chimney should be swept at least
twice a year. Where a top outlet is
used it will generally be possible to

Tool

Pull Forward and Swing Down

Tool

Throat Plate

Throat Plate

Pull Forward and Swing Down

Country 8

Country 12

Fig. 3. Throat Plate Location

Page 5

TW16 3/99

Содержание Country 12 Mk2

Страница 1: ...on Instructions CHARNWOOD Country 8 MkII and Country 12 MkII Flat Top Low Canopy High Canopy Multifuel Roomheaters Bishops Way Newport Isle of Wight PO30 5WS U K Tel 01983 537799 Fax 01983 537788 E Mail charnwood ajwells co uk ...

Страница 2: ... Trouble Shooting 6 Installation Instructions Health Safety Precautions 7 Performance 7 Chimney 7 Hearth and Fire Surround 7 Hot Water System 7 Fitting The Optional Add In Boiler 8 Connections To Flues 8 Soot Doors 9 Pre Lighting Check 9 Commissioning 9 Overall Dimensions Country 8 10 Overall Dimensions Country 12 11 CHARNWOOD COUNTRY 8 Mk II COUNTRY 12 Mk II Operating and Installation Instruction...

Страница 3: ...son in a well ventilated dry place for at least one year but preferably two years before use Peat Ensure that the peat is well dried before use Burning wet peat will give rise to heavy tar deposits and reduced outputs PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE ITS USE WILL INVALIDATE THE GUARANTEE At first you may find it helpful to try several fuels to find the most suitable If you ...

Страница 4: ...ning wood or peat ash should be allowed to build up and generally weekly riddling will be sufficient The fire should be riddled with the doors shut see Fig 2 Place the tool onto the riddling lever and rotate between the 1 o clock and 3 o clock positions several times Too much riddling can result in emptying unburnt fuel into the ashpan and should therefore be avoided If any clinker forms it should...

Страница 5: ...t use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire When not in use If the fire is going to be out of use for a long period for instance in the summer then to prevent condensa tion and hence corrosion the thermostat should be left at the maximum ...

Страница 6: ...hanging the front firebars will cause the glass to blacken It is always more difficult to keep the glass clean when running the stove very slowly for long periods If blackening of the glass still occurs check that the top of the stove is bolted on securely and that the seal between the top and the body is intact Also check that all flue connections and the blanking plate are well sealed It is also...

Страница 7: ...sought regarding the necessity of having the chimney lined If it is found necessary to line the chimney then a lining suitable for Solid Fuel must be used If there is no existing chimney then a prefabricated block chimney or a twin walled insulated stainless steel flue to BS 4543 can be used either internally or externally These chimneys must be fitted in accordance with the manufacturers instruct...

Страница 8: ...hers over the tappings on the outside of the appliance and fit the backnuts ensuring that the boiler is held tightly against the rear inside face of the appliance and that the top edge of the boiler is level or runs uphill to the flow tapping Gaps between the boiler and the firebricks should be filled with fire cement Replace the back fireplate the side fireplates and the front firebar On the Coun...

Страница 9: ...ust all be fitted and should move freely and easily when the riddling mechanism is operated 2 The plates round the sides and back of the grate must be in position and sitting correctly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The method of location and positioning of the throat plate is shown in fig 3...

Страница 10: ...High Canopy Country 8 LC Low Canopy Country 8 FT Flat Top 552 508 381 1012 526 526 526 381 752 552 513 322 513 381 513 513 322 513 322 639 513 460 1072 106 587 812 126 699 587 587 46 469 46 461 125 Country 8 MkII Dimensions All dimensions are in mm Page 10 TW16 3 99 ...

Страница 11: ...0 180 210 180 210 655 1098 320 462 386 518 1158 584 106 45 655 793 320 Ø154 462 386 518 853 584 125 489 45 658 595 320 Ø154 462 386 518 718 584 125 468 45 Ø154 616 480 Country 12 HC High Canopy Country 12 LC Low Canopy Country 12 FT Flat Top Page 11 TW16 3 99 ...

Отзывы: