background image

11

®

in the ‘minimum distances to combustibles’ section (pages 12 - 14)  
When the fire door is open, it extends beyond the flat front of the 
stove by 450mm.

If in doubt as to the positioning of the stove, expert advice should be 
sought either from the supplier or the local building inspector. The 
fireplace must allow good circulation of air around the appliance to 
ensure that maximum heat is transferred to the room and also to 
prevent the fireplace from overheating. A gap of 150mm (6”) each 
side and 300mm (12”) above the appliance should give sufficient air 
circulation. If a wooden mantelpiece or beam is used in the fireplace 
it should be a minimum of 460mm (18”), and preferably 600mm 
(24”) from the appliance. In some situations it may be necessary to 
shield the beam or mantelpiece to protect it.

In order for the fire to operate correctly the rear air inlet must not 
be obstructed.

The appliance should be installed on a floor with adequate load-
bearing capacity. If an existing construction does not meet this 
requirement then please take suitable measures to achieve this. (e.g. 
load distributing plate.)

CONNECTIONS TO FLUES

The Arc 7 must be connected to the flue using flue pipe of 150mm 
(6”) diameter  : and is tested for both Air Cooled triple Skin Flue 
Kits & Room Seal Insulated flue Kits that have been tested to AS/
NZS2918:2018 

Horizontal lengths of flue must be kept to a minimum and should not 
be more in length than the flue diameter.

The stove comes with the blanking plate (fig. 7) fitted to the

 

rear 

flue outlet. The seal for the top outlet is a 155mm dia ring of rope 
seal. The seal for the rear outlet is a length of adhesive backed 
fibre webbing supplied with instructions ref: TIS093. This is applied 
to the flue collar or the Vertical Rear Flue adapter for rear outlet 
installations.

The  top outlet connection is made directly to the cast top of the Arc 
7, the Arc 7 is supplied with a flue collar for rear outlet installations.

PRE LIGHTING CHECK

Ensure that the baffle and upper baffle is fitted in the roof of the 
appliance. For location and positioning see Fig. 6.

Check that the front fence is fitted correctly and that the door closes 
properly.

COMMISSIONING

Ensure that the rear heatshield extension is fitted to the back of the 
heaishield (part  010/BPA170) with 2 x 12mm self tapping screws. 

This part must be supplied and fitted to the stove

. On completion 

of the installation allow a suitable period of time for the fire cement 
and mortar to dry out before lighting the fire. Make a layer of ash 
or sand on the base of the stove before lighting. Check to ensure 
that smoke and fumes are taken from the appliance up the flue and 
emitted safely. Also check all joints and seals. On completion of the 
installation and commissioning please leave the operating instructions 
with the customer and advise them on the use of the appliance. 

COOKING PLATE

010/BP150S - 6 inch kit used on the Arc 7
The kit comprises of a cooking plate and four trivets and can only be 
fitted to the stove if a rear flue connection is made.

Fig. 7. Flue Blanking Plate.

INSTALLATION INSTRUCTIONS

Back of Stove

Blanking Plate

Glass Fibre Webbing

Blanking Plate

Seal Blanking Plate with 

Glass Fibre Webbing

Clamping plate finishes flush 

with the inside face of the 

firebox top and bottom.

Inside of Stove

Clamping Plate

M8 Nut

Содержание ARC 7

Страница 1: ... Operating Installation Instructions AUSTRALIA ...

Страница 2: ......

Страница 3: ...Y PRECAUTIONS 10 FLUE 10 HEARTH AND FIRE SURROUND 10 CONNECTIONS TO FLUES 11 PRE LIGHTING CHECK 11 COMMISSIONING 11 COOKING PLATE 11 CLEARANCES 15 STANDARD HEARTH DIMENSIONS 16 CORNER HEARTH DIMENSIONS 17 FLUE CLEARANCES DIAGRAM 18 STANDARD DEFAULT TRIPLE SKIN FLUE KIT 19 INSULATED ROOM SEAL FLUE KIT 20 INSULATED ROOM SEAL FLUE KIT 21 INSULATED ROOM SEAL FLUE KIT 22 COMPLIANCE DATA 23 ARC 7 DIMENS...

Страница 4: ...ol can be reduced to minimum Baffle Improves efficiency of stove by slowing down flue gases Door Keep closed when stove is in use Door handle Pull to open Riddler knob Use operating tool to riddle Fuel retainer Ensure fuel does not protrude beyond retainer MAINTENANCE AND CLEANING GLASS Wipe with damp lint free cloth Any stubborn deposits on the glass may be removed with a proprietary stove glass ...

Страница 5: ...t designed to burn household waste LIGHTING On initial lighting the stove may smoke and give off an odour as the silicon paint with which the firebox is painted reacts to the heat This is normal and will cease after a short time but meanwhile the room should be kept well ventilated At first only light a small fire and burn it slowly for two hours to allow any residual moisture in the flue to evapo...

Страница 6: ...ld be moved between the clockwise and anticlockwise positions several times When burning wood the ash should be allowed to build up and riddling should only be carried out once or twice a week Fig 2 Operating the wood ash removal grate RIDDLING When burning wood ash should be allowed to build up and only riddled when the ash begins to cover the rear fireplate The fire should be riddled with the do...

Страница 7: ...aning The stove is finished with a high temperature paint which will withstand the temperatures encountered in normal use This may be cleaned with a damp lint free cloth when the stove is cold Should re painting become necessary high temperature paints are available from your supplier or from stove shops Cleaning the Glass Most deposits on the glass may be burnt off simply by running the fire at a...

Страница 8: ... gas temperature from a stove may loosen soot deposits with the consequent risk of flue blockage It is therefore recommended that the flue be swept a second time within a month of regular use after installation Your Charnwood flue should be swept at least twice a year Where the top outlet or vertical rear flue connector is used it will generally be possible to sweep the flue through the appliance ...

Страница 9: ...ng immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely dispose of the fuel from the appliance c Check for flue or flue blockage and clean if required d Do not attempt to re light the fire until cause of fuming has been identified if necessary seek professional advice The most common cause of fume emission is a f...

Страница 10: ...able please contact Charnwood for more information Instruction sheet ref TIS 120 It is recommended that a carbon monoxide alarm is installed in the same room as the appliance in accordance with the alarm manufacturer s instructions SPECIFICATION FLUE In order for the appliance to perform satisfactorily the flue must give sufficient draw when warm minimum of 12pa 0 05 wg The height of the flue must...

Страница 11: ...dia ring of rope seal The seal for the rear outlet is a length of adhesive backed fibre webbing supplied with instructions ref TIS093 This is applied to the flue collar or the Vertical Rear Flue adapter for rear outlet installations The top outlet connection is made directly to the cast top of the Arc 7 the Arc 7 is supplied with a flue collar for rear outlet installations PRE LIGHTING CHECK Ensur...

Страница 12: ...12 CLEARANCES PARALLEL POSITION COMBUSTIBLE WALLS CORNER POSITION Standard Clearance A 200mm B 369mm C 400mm D 648mm ARC 7 STORE STAND LOW Corner Clearance A 275mm B 533mm A B C D A A B ...

Страница 13: ...mm E 200mm MIN DIMENSIONS TO WALL A 1490mm B 755mm C 420mm D 275mm E 458mm VERTICAL REAR FLUE ADAPTOR ARC 7 STORE STAND LOW NON COMBUSTIBLE MATERIAL Minimum thickness 24mm Minimum thermal resistivity 0 026m2 K W Installed in accordance with AS NZS 2918 2018 3 3 2 DEFAULT HEARTH B C D D A TO WALL B E C D D A VERTICAL REAR FLUE ADAPTOR B E C D D A ...

Страница 14: ... FLUE ADAPTOR CORNER HEARTH A 755mm B 275mm C 420mm WITH VERTICAL REAR FLUE ADAPTOR A 755mm B 275mm C 420mm D 458mm ARC 7 STORE STAND LOW C A B B NON COMBUSTIBLE MATERIAL Minimum thickness 24mm Minimum thermal resistivity 0 026m2 K W Installed in accordance with AS NZS 2918 2018 3 3 2 C A B B D D ...

Страница 15: ... top Increase from 1000 min until clear within 3000 of flue top DIMENSIONS IN MILLIMETRES Summary of minimum height of flue sytem exit requirements from AS NZS 2918 2018 More than 3000 More than 3000 600 min 600 min 3000 Any nearby structure Increase as necessary until nothing within 6000 of flue top ...

Страница 16: ...16 150 1000 1000 1000 1000 25 600 Cowl Triple skin flue Flashing Optional Decorative Flue Solid OR Mesh Ceiling Ring Dropbox STANDARD DEFAULT TRIPLE SKIN FLUE KIT ...

Страница 17: ...17 INSULATED ROOM SEAL FLUE KIT 185 1000 1000 1000 25 50 Single skin flue Room sealed flue adaptor Ceiling ring Heatshield Starter length flue Cowl Room sealed flue with locking band STANDARD FLUE KIT ...

Страница 18: ...18 INSULATED ROOM SEAL FLUE KIT FULLY SEALED FLUE KIT 1000 1000 1000 1000 25 50 Cowl Ceiling ring Heatshield Starter length flue Room sealed flue with locking band ...

Страница 19: ...mm clearance to any timber to the side and underneath Min 470 Max 620 Cowl Adjustable wall bracket Cleaning access Wall Plate INSULATED ROOM SEAL FLUE KIT REAR FLUE KIT Room sealed flue with locking band Room sealed flue with locking band Room sealed flue adaptor 90 degree tee with cap Wall plate gal Ceiling ring Roof support brace ...

Страница 20: ...20 COMPLIANCE DATA ARC 7 COMPLIANCE DATA Compliance plate riveted onto rear heatshield ...

Страница 21: ...ARC 7 DIMENSIONS LOW STAND STORE STAND FRONT SIDE REAR PLAN VIEW Optional rear flue adaptor To suit 150mm 6 flue pipe 516 138 169 455 493 502 1040 1023 159 449 311 832 493 502 449 815 159 79 98 79 894 686 ...

Страница 22: ...ling Gasket 26 010 KZ133 Blanking Plate Retainer 27 010 AY51 Clamping Plate 28 010 EZ012 Top Retaining Bracket 29 002 KZ003 Door Back Plate 30 002 KZ001 A Door Casting 31 010 EZ061 Upper Latch Receiver Plate 32 010 KZ058 Lock Linkage Assembly 33 008 EZ106 Door Handle 34 010 KZ064 Lower Latch Reciever Plate 35 002 KZ053 Lower Hinge Bracket 36 002 KZ054 Upper Hinge Bracket 37 010 KZ044 Air Control S...

Страница 23: ...Z009 Cast Top 24 010 KZ132 Blanking Plate 25 008 KS134 Flue Sealing Gasket 26 010 KZ133 Blanking Plate Retainer 27 010 AY51 Clamping Plate 28 010 EZ012 Top Retaining Bracket 29 002 KZ003 Door Back Plate 30 002 KZ001 A Door Casting 31 010 EZ061 Upper Latch Receiver Plate 32 010 KZ058 Rod Handle Assembly 33 008 EZ106 Door Handle 34 010 KZ064 Lower Latch Reciever Plate 35 002 KZ053 Lower Hinge Bracke...

Страница 24: ...facturer at the address shown This drawing is for identification purposes only Prices are shown in pounds sterling with vat at 20 They are correct at the date shown but may be subject to change without notice E O E 1 010 KZ120 Drawer Kit Optional Extra 196 00 235 20 2 010 KZ127 Drawer NA 3 010 KZ096 Drawer Base Plate 27 00 32 40 4 004 KZ129L LH Drawer Support 12 80 15 36 5 004 KZ129R RH Drawer Sup...

Страница 25: ...and must be accompanied by proof of purchase Nothing in this guarantee shall affect your statutory rights EXCLUSIONS AND LIMITATIONS This Guarantee does not cover the following Charnwood will not be liable for any consequential loss or incidental loss damage or injury however caused This guarantee will become void if the appliance is not installed by a suitably qualified and is not installed in ac...

Страница 26: ...your premier dealer ...

Отзывы: