11
®
in the ‘minimum distances to combustibles’ section (pages 12 - 14)
When the fire door is open, it extends beyond the flat front of the
stove by 450mm.
If in doubt as to the positioning of the stove, expert advice should be
sought either from the supplier or the local building inspector. The
fireplace must allow good circulation of air around the appliance to
ensure that maximum heat is transferred to the room and also to
prevent the fireplace from overheating. A gap of 150mm (6”) each
side and 300mm (12”) above the appliance should give sufficient air
circulation. If a wooden mantelpiece or beam is used in the fireplace
it should be a minimum of 460mm (18”), and preferably 600mm
(24”) from the appliance. In some situations it may be necessary to
shield the beam or mantelpiece to protect it.
In order for the fire to operate correctly the rear air inlet must not
be obstructed.
The appliance should be installed on a floor with adequate load-
bearing capacity. If an existing construction does not meet this
requirement then please take suitable measures to achieve this. (e.g.
load distributing plate.)
CONNECTIONS TO FLUES
The Arc 7 must be connected to the flue using flue pipe of 150mm
(6”) diameter : and is tested for both Air Cooled triple Skin Flue
Kits & Room Seal Insulated flue Kits that have been tested to AS/
NZS2918:2018
Horizontal lengths of flue must be kept to a minimum and should not
be more in length than the flue diameter.
The stove comes with the blanking plate (fig. 7) fitted to the
rear
flue outlet. The seal for the top outlet is a 155mm dia ring of rope
seal. The seal for the rear outlet is a length of adhesive backed
fibre webbing supplied with instructions ref: TIS093. This is applied
to the flue collar or the Vertical Rear Flue adapter for rear outlet
installations.
The top outlet connection is made directly to the cast top of the Arc
7, the Arc 7 is supplied with a flue collar for rear outlet installations.
PRE LIGHTING CHECK
Ensure that the baffle and upper baffle is fitted in the roof of the
appliance. For location and positioning see Fig. 6.
Check that the front fence is fitted correctly and that the door closes
properly.
COMMISSIONING
Ensure that the rear heatshield extension is fitted to the back of the
heaishield (part 010/BPA170) with 2 x 12mm self tapping screws.
This part must be supplied and fitted to the stove
. On completion
of the installation allow a suitable period of time for the fire cement
and mortar to dry out before lighting the fire. Make a layer of ash
or sand on the base of the stove before lighting. Check to ensure
that smoke and fumes are taken from the appliance up the flue and
emitted safely. Also check all joints and seals. On completion of the
installation and commissioning please leave the operating instructions
with the customer and advise them on the use of the appliance.
COOKING PLATE
010/BP150S - 6 inch kit used on the Arc 7
The kit comprises of a cooking plate and four trivets and can only be
fitted to the stove if a rear flue connection is made.
Fig. 7. Flue Blanking Plate.
INSTALLATION INSTRUCTIONS
Back of Stove
Blanking Plate
Glass Fibre Webbing
Blanking Plate
Seal Blanking Plate with
Glass Fibre Webbing
Clamping plate finishes flush
with the inside face of the
firebox top and bottom.
Inside of Stove
Clamping Plate
M8 Nut