INSTALLATION INSTRUCTIONS
Fig. 11 Limiting Dimensions of Surround and Opening
Dimension A:
Min. 615mm
Max. 650mm
Min. 620mm
Max 650mm
Dimension B:
Min. 410mm
Max. 440mm
Min. 510mm
Max. 540mm
Dimension C:
Min. 380mm
Min. 400mm
The shaded grey area on the face of the surround is
the minimum flat area required for inset installation.
B
A
C
700mm
600mm
HEARTH AND FIRE SURROUND
The stove must be installed above a fireproof hearth of minimum
250mm depth in accordance with local building regulations, but
ideally 580mm deep to match the projection of the open door. The
positioning of the stove and the size of the hearth
If a wooden mantelpiece or beam is used in the fireplace it should be
a minimum of dimension ‘D’ fr
om the appliance. In some situations it
may be necessary to shield the beam or mantelpiece to protect it.
In order for the appliance to fit into the fire surround there must be a
flat area around the opening. Details are shown in Fig. 11.
are governed by
building regulations for Class 1 appliances. If in doubt as to the
positioning of the stove expert advice should be sought either from
the supplier or the local building inspector.
Bay 5
Bay 5GT
Top of stove
Fireplace
(Non-combustible)
Calcium silicate board
80mm for Bay 5
100mm for Bay 5GT
100mm air gap
Air vent through insulation and
wall of fireplace (Two on each side)
Ø80mm for Bay 5
Ø100mm for Bay 5GT
PREPARATION OF FIREPLACE
If the fireplace contains combustible materials, two air vents of 80mm
(Bay 5) or 100mm (Bay 5GT) diameter must be fitted through the
insulation and the wall of the fireplace to provide a continual air flow
around the stove. Similar vents must be placed between the closure
plate and the top of the stove to ventilate the cavity. It is
recommended that Calcium Silicate board is used (80mm board for
Bay 5, 100mm board for Bay 5GT), with a 100mm air gap between
the stove and the insulation (see Fig. 10).
If the fireplace does not contain combustible materials, it is still
recommended to have a layer of insulation or ventilate the space
between the casing and the outer wall. The insulation may consist of a
layer of mineral fibre or a vermiculite concrete mix (see Step 4). If
rockwool is being used, insert this into the opening before sliding in
the convection casing.
Before fitting the appliance into an existing fireplace remove the
fireback and any loose in-fill material.
The surround and opening for the appliance must conform with
Fig.11. The flat area around the opening should be a minimum of
700mm wide and 600mm high. Ensure that the hearth and the base
in the opening are flat, level, and at right angles to the surround.
For the Bay 5GT, consider where the low voltage power supply for
the fans is to be situated, and install electrical conduit from that point
to back left of the convection casing.
Fig. 10 Air vents and insulation in a fireplace containing combustible
materials
Fig. 9 Minimum Distances from Combustibles
charnwood
BAY
A
Bay 5 Bay 5GT
Dimension A: 190mm 150mm
Dimension B: 250mm 250mm
Dimension C: 900mm 1000mm
Dimension D: 350mm 460mm
Hearth
Mantelpiece
A
B
D
C
From centre of
glass into room