Figure 3. Installation of the monitor to the worksurface
one snap at a time.
NOTE:
Install the monitor to the worksurface by aligning
one snap at a time and applying a downward force
directly above that snap.
Figure 4. Operating the Jewel
®
Workstation Continuous
Mini Monitor.
The following procedure will outline how to correctly wire
the Jewel
®
Workstation Continuous Mini Monitor so as to
properly monitor an ESD protected workstation.
1. Confirm that the worksurface surface resistance is
5 x 10
8
ohms or less and has a conductive layer.
2. A convenient outlet should be located and tested for
proper wiring and grounding. We recommend the
Charleswater
99142
AC Outlet Analyzer to verify
proper wiring and ground.
3. Plug the AC Adapter into the outlet and connect
the mini plug into the back side of the Monitor. The
green Worksurface LED should be lit. The Monitor
is now ready for use. If the red Worksurface LED
is flashing, check the snap fasteners for proper
connection.
Installation on Micastat
®
Laminate
Materials Needed:
2
90202
Flush Mount Laminate Ground Inserts
1
90200
Installation Tool for Flush Mount Insert
1
10mm Socket and Rivet (100 per pack)
2 8-32 button cap screws
1. Install the
90202
Flush Mount Inserts in the snap
pattern for the monitor.
2. Once installed, remove the 8-32 screw supplied.
3. Place a 10mm snap socket on top of the installed
90202
brass insert.
4. Screw the 10mm snap socket into place on the insert
using an 8-32 button cap screw.
5. Do this for both inserts and snap attach the mini
monitor into place; it is now grounded to and
monitoring the Micastat
®
.
Operation
When the Jewel
®
Workstation Continuous Mini Monitor
is installed and is connected to an ESD protective work
surface, and it is grounded via an AC adapter cord, the
monitor’s green Worksurface LED and its red Operator
LEDs should be on. The monitor takes 6 seconds to
activate its alarm circuitry when it is first plugged in.
• The custom AC adapter connects the ground outlet to
the barrel on the output plug.
• The AC adapter therefore supplies the Monitor with
ground.
• The mat resistance is measured between the two
snaps on the bottom of the unit.
• This monitor simplifies the workstation, eliminating
the need for a separate mat ground cord.
TO USE THE MONITOR
1. Plug a wrist strap cord banana plug into the
monitored banana jack on the front of the unit. The
included banana plug / 10mm adapter may be
inserted into this jack if a wrist cord with a 10mm
snap is to be used with the monitor. This
automatically activates the operator channel. The red
operator LED should illuminate.
NOTE:
The monitor is not compatible with wrist cords
that have 1 megohm resistors at both terminations. The
termination with the 1 megohm resistor must always be
connected to the operator and not the monitor.