Load Regulation:
Better than 8% NL to FL where FL =
10E9 Ohms

Environment:
10 - 30°C (50 - 86°F) at 10-80% RH
(non-condensing)

Power:
9 VDC alkaline battery
30 hours battery life

Size:
8.9 cm x 6.4 cm x 2.5 cm

Weight:
0.079 kg

Limited Warranty

Charleswater expressly warrants that for a period
of one (1) year from the date of purchase,
Charleswater Ionisation Test Kits will be free of
defects in material (parts). Within the warranty
period, the material will be tested, repaired or
replaced at Charleswater’s option, free of charge.
Call Customer Service at 00 44 (0) 1892-665313
for a Return Material Authorisation (RMA) and for
proper shipping instructions and address.  You
should include a copy of your original packing slip,
invoice, or other proof of purchase date.  Any unit
under warranty should be shipped prepaid to the
Charleswater factory. Warranty replacements will
take approximately two weeks.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS
MADE IN LIEU OF ALL OTHER PRODUCT
WARRANTIES, EXPRESSED AND IMPLIED,
INCLUDING MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE
WHICH ARE SPECIFICALLY DISCLAIMED.
The express warranty will not apply to defects
or damage due to accidents, neglect, misuse,
alterations, operator error, or failure to properly
maintain, clean or repair products.

Limit of Liability

In no event will Charleswater or any seller be
responsible or liable for any inury, loss or
damage, direct or consequential, arising out of
the use of or the inability to use the product.
Before using, users shall determine the
suitability of the product for their intended use,
and users assume all risk and liability
whatsoever in connection therewith.

Unit 17. Millbrook Business Park, Sybron Way • Crowborough, East Sussex TN6 3JZ United Kingdom

Phone: 00 44 (0) 1892-665313, Fax: 00 44 (0) 1892-668838 • E-mail: [email protected], Internet: Charleswater.co.uk

PPE-5084.E

Page 4 of 4

© 2007 CHARLESWATER LTD.

Содержание 99152

Страница 1: ...evice is removed from the region of the electrostatic field and grounded again a second CDM event will occur as charge of opposite polarity from the first event is transferred from the device Handbook ESD TR20 20 section 2 7 5 Field Induced Discharges Compliance verification should include periodic checks with a static field meter to determine if high charging material is present in the ESD protec...

Страница 2: ...ness Park Sybron Way Crowborough East Sussex TN6 3JZ United Kingdom Phone 00 44 0 1892 665313 Fax 00 44 0 1892 668838 E mail info charleswater co uk Internet Charleswater co uk PPE 5084 E Page 2 of 4 2007 CHARLESWATER LTD Per ESD TR53 2006 Compliance Verification of ESD Protective Equipment and Materials Air Ioniser Test Procedure Initial Test Setup Measurements should be made at the location wher...

Страница 3: ...brated If for any reason you believe the meter is not working correctly please contact Charleswater Customer Service CAUTION There are no user serviceable parts Any unauthorized service will void the warranty and result in additional repair charges Maintenance BATTERY REPLACEMENT The Digital Static Field Meter and operates from a standard 9 VDC alkaline battery Battery life is in excess of 30 hour...

Страница 4: ...ts will take approximately two weeks Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations operator error or failure to properly mainta...

Отзывы: