SK5BB Operator’s Manual
Service and Specifications - 19
Service
Service and Specifications
Service
10-Hour
Check Hydraulic Hoses and Fittings
Check hydraulic hoses for leaks every 10 hours.
Task
Notes
Check hydraulic hoses and fittings (with hydraulic swing)
Check condition of backfill blade
Fluid or air pressure could pierce skin and cause injury or
death. Stay away.
NOTICE:
•
Escaping pressurized fluid can cause injury or pierce skin and poison.
•
Before disconnecting a hydraulic line, turn engine off and operate all controls to relieve pressure.
Lower, block, or support any raised component with a hoist. Cover connection with heavy cloth and
loosen connector nut slightly to relieve residual pressure. Catch all fluid in a container.
•
Before using system, check that all connections are tight and all lines are undamaged.
•
Fluid leaks can be hard to detect. Use a piece of cardboard or wood, rather than hands, to search
for leaks.
•
Wear protective clothing, including gloves and eye protection.
•
If you are injured, seek immediate medical attention from a doctor familiar with this type of injury.