3S-16S LiPolymer battery Monitor and Saver                                    BM16LP V2.0

 

www.chargery.com

                                                                                                                           

page 2    total 5

 

Chargery Battery Saver BM16LP is for 3S ~ 16S LiPolymer battery applied to E-bike, E-scooter etc., 

High light red LED and loud beepers (85Db) make sure battery operation safety. The unit is with TFT 

color  LCD  display  battery  voltage,  cell  voltage,  2  battery  temperature,  and  battery  SOC  (State  of 

Charge).  You  can  setup  over  discharge  warning  cell  voltage, 

over  charge  warning  voltage

,  the 

highest battery temperature and the lowest battery gauge for warning.   

   

During battery discharge, if any cell voltage under setup value, or battery temperature over setup or 

battery gauge under setup, the BM16LP can sound and LED flash alternately prevent any cell from 

over discharged.   

During battery charge, if any cell voltage over setup value, or battery temperature over setup, the 

BM16LF can sound and LED flash alternately prevent any cell from over charged.   

 

When you stop driving your bike or scooter, you can check the lowest cell voltage, so you can find the 

worst cell---the lowest voltage cell. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

New features 

 

BM16LP can indicate battery SOC or called battery gauge similar with car dashboard. Cell count, 

battery pack voltage and battery gauge (%) is displayed simultaneously. 

 

BM16LP will record the lowest voltage of each cell during discharge, after you stop driving your 

bike, scooter etc., you can press UP or DOWN    button to display these voltages (

cell number 

background color is green, and the lowest cell voltage displayed in 

RED

 text

), press the 

button again display real voltage.   

 

Beeper sound and LED flash alarm alternately while any cell over charged or over discharged. 

 

Two temperature sensors monitor battery temperature during charge or discharge. 

 

At any time, you can press SET button shortly turn off the display and press again resume. 

 

While alarming, press SET button shortly turn off alarm. 

 

Operating guideline 

1.

 

Connect the battery to BM16LP, keep the polarity correct. The detailed connection diagram is as 

the following figure 1 and figure 2. 

2.

 

The unit will initialize the beeper and LED, beeper sounds once time, warning LED flash once time. 

3.

 

2 seconds later, the BM16LP will display battery SOC (State Of Charge) as same as car dashboard., 

two  battery  temperatures,  cell  count,  battery  pack  voltage,  and  battery  gauge  in  digital 

Socket 1 

Socket 2 

Cell 1- 
Cell 2- 
Cell 3- 
Cell 4- 
Cell 5- 
Cell 6- 
Cell 7- 
Cell 8- 
Cell 8+ 

Cell 9- 
Cell 10- 
Cell 11- 
Cell 12- 
Cell 13- 
Cell 14- 
Cell 15- 
Cell 16- 
Cell 16+ 

SET 

DOWN    UP 

LED 

BEEPER 

Temperature sensor 

Temperature sensor 

Содержание BM16LP

Страница 1: ...ontrolled high performance Battery Monitor For 3S 16S LiPoly battery pack Chargery Power Co Ltd Head Office Add Chuangye Road Nanshan Shenzhen 518054 China Zip code 518054 Tel 86 755 2643 6165 Fax 86 755 2641 2865 Email admin chargery com cn Web www chargery com ...

Страница 2: ...oard Cell count battery pack voltage and battery gauge is displayed simultaneously BM16LP will record the lowest voltage of each cell during discharge after you stop driving your bike scooter etc you can press UP or DOWN button to display these voltages cell number background color is green and the lowest cell voltage displayed in RED text press the button again display real voltage Beeper sound a...

Страница 3: ...m pin distance balance connector for all kinds of battery Connection Diagram There are 2 sockets connecting to battery pack socket 1 is for 3S 8S and socket 2 for 9S 16S battery 1 One 3S to 8S battery can plug into the socket 1 directly 6S connections as following Figure 1 2 For two battery packs connect them in series first and then plug battery 1 into socket 1 and battery 2 into socket 2 separat...

Страница 4: ...erature 1 Connect your battery to BM16LP 2 Press SET button for 3 seconds enter into Program Setup menu 3 Press UP or DOWN button select the item press SET shortly make the value flash and press UP or DOWN change the value Press SET button shortly confirm the change After finish all setup press SET for 3 seconds quit the setup menu 4 Over charge warning voltage range is 3 90 4 30V per cell step 0 ...

Страница 5: ...acturing defect the accessory will be replaced or repaired Your selling dealer is your first point of contact for warranty issues Return postage costs are the responsibility of the user in all cases Please submit copy of original receipt with the return Damage due to physical shock dropping on the floor etc inappropriate power supply unstable output voltage and insufficient power etc water moistur...

Отзывы: