About Aura Dual Pole Mount 

By adding the Pole Mount, specifically designed for Aura, you open up the possibilities for 
installing two chargers on a 60 mm outer diameter pole e.g. an existing motor heater pole.  
 
Contact your supplier for more information about your specific Aura Dual Pole Mount. 

Contents of the package 

In the packaging, below is included: 

 

Aura Dual Pole Mount 

 

Installation kit, zip-lock bag containing O-ring 60 x 2mm, 4 pcs. of M6 bolts, 4 

pcs. of M6 nuts, 8 pcs. M6 washers, 5 pcs M4 screws, 1 tooth washer M4 and 6 

pcs. of M6 pin stop screws. 

NOTE: The four M6 x 20 mm screws included in the Aura product kit will be used 

for mounting Aura on the pole mount. 

 

Installation manual 

 

Data sheet of the included terminal block 

Provided by the installer 

 

Torx drive T30 (used for M6 x 20 mm screws included in the Aura product kit) 

 

Torx drive T20 (used for M4 x 8 mm screws) 

 

SDK PZ2 (Terminal block) 

 

2 x M6 socket wrench size 10 with extender (used for M6 screws / nuts) 

 

Hex key M6 (used for M6 pin stop screws) 

 

Screwdriver (manual or power tool) 

 

Proper cables for L1

L3, N, PE and necessary tools for cutting, stripping etc. 

 

Before installation 

Make sure that the right conditions and materials are in place before installation. The 
installation must be done in accordance with the instructions in this installation manual as 
well as basic safety precautions. 
 

Содержание Aura Pole Mount

Страница 1: ...Charge Amps Aura Dual Pole Mount Installation manual...

Страница 2: ...ps com www chargeamps com Org No 556897 7192 Registered office Solna 2 Table of Contents User Agreement 3 Greetings installer 4 About Aura Dual Pole Mount 5 Contents of the package 5 Provided by the i...

Страница 3: ...cannot be used without two Charge Amps Auras installed properly The Aura Dual Pole Mount and the two Charge Amps Auras should be regarded as one assembly The power should be switched off during the co...

Страница 4: ...7192 Registered office Solna 4 Greetings installer This installation manual is intended for qualified Aura Pole Mount installers and describes how to install the product safely and properly Installati...

Страница 5: ...cs of M6 bolts 4 pcs of M6 nuts 8 pcs M6 washers 5 pcs M4 screws 1 tooth washer M4 and 6 pcs of M6 pin stop screws NOTE The four M6 x 20 mm screws included in the Aura product kit will be used for mou...

Страница 6: ...t 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 6 Model view Aura Dual Pole Mount 1 Aura Dual Pole Mount 2 Din Rail 3 Lid 4 1 pcs EPDM Gasket 5 4...

Страница 7: ...ng on the preferred height of the charger the 60 mm pole might have to be cut That power is shut off during the whole installation Step 1 The terminal block or any other preferred electronic component...

Страница 8: ...den 2B SE 169 75 Solna Sweden Contact 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 8 Step 3 Slide the O ring onto the pole Then slide the pole m...

Страница 9: ...1 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 9 Step 4 Tighten the 6 pcs of M6 pin stop screws which fixates the pole mount onto the pole Use the hex key M6...

Страница 10: ...info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 10 Step 5 1 Unscrew the two M6 x 20 screws from the bottom of the Aura and remove the bracket highlighted in blue in...

Страница 11: ...chargeamps com Org No 556897 7192 Registered office Solna 11 Attach the two M6 x 20 screws so that it connects the pole mount and the Aura The screws should just temporarily fixate the Aura they shoul...

Страница 12: ...s AB Fr sundaleden 2B SE 169 75 Solna Sweden Contact 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 12 Step 7 1 Slide the next Aura unit to the po...

Страница 13: ...1 Address Charge Amps AB Fr sundaleden 2B SE 169 75 Solna Sweden Contact 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 13 Side Front view 3 Tight...

Страница 14: ...the front Depending on the installation type Option1 1 If you got two incoming power cables pull them through the pole mount 2 Close the lid make sure that no cable or obstacle is in contact with the...

Страница 15: ...tact 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 15 2 Connect the earthing circuit to the earthing screw M4 tooth washer 3 Cut new appropriate...

Страница 16: ...e the lid make sure that no cable or obstacle is in contact with the lid If a cable push on the lid the IP 44 protection will fail Option 3 1 If you got one incoming power cable and one outgoing read...

Страница 17: ...geamps com Org No 556897 7192 Registered office Solna 17 2 Cut new appropriate cables connect them to upper side of the terminal block and pull them through the bottom of the Aura Connect the first se...

Страница 18: ...55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 18 4 Close the lid make sure that no cable or obstacle is in contact with the lid If a cable push on the...

Страница 19: ...en installed properly Product recycling Recycling is part of any products lifecycle Aura Dual Pole Mount contains stainless steel and should be recycled accordingly Rights The information in this docu...

Отзывы: