Charder R460 Скачать руководство пользователя страница 3

R460 Keg Scale 

                                                                                               . 

 2 

INTRODUCTION

 

This user manual will guide you through the correct operating procedure for the 

R460 Keg Scale, please read this manual thoroughly before operation and keep it 

at hand for future reference. 

 

R460 Keg Scale Maximum Weight Capacity: 200kg. 

 

 

SAFETY PRECAUTIONS 

Please follow these safety precautions: 

X

 

DO NOT insert liquids or foreign object. 

X

 

DO NOT operate the scale in hostile environments. 

X

 

DO NOT drop loads/leave permanent load on the platform. 

X

 

DO NOT place the scale upside down on the pan. 

X

 

DO NOT open the scale. Attempts to make repairs might cause injuries. 

Product warranty considered void if this stipulation is ignored. 

The scale must only be repaired by authorized personnel. 

Ö

 

Verify power adapter input voltage matches the local power supply. 

Ö

 

Unplug power adaptor and remove battery before assembling the scale. 

 

Risk of explosion can occur if battery is replaced with the wrong type or 

connected improperly. Do not disassemble, repair or otherwise manipulate the 

battery socket. 

Obey local laws and regulations on battery disposal. 

 

DISPOSAL 

 

In conformance with the European Directive 2002/96 EC on Waste Electrical 

and Electronic Equipment (WEEE), this device may not be disposed of with 

domestic waste. 

 

This also applies to countries outside the EU, according to their specific 

requirements. 

 

Please dispose of this product in accordance with local regulations at the 
collecting point specified for electrical and electronic equipment. 

 

For more detailed information about recycling this product, please contact the 

local distributor from which you purchased this device. 

 

 

Содержание R460

Страница 1: ...Please read this manual carefully before operating the device and keep it at hand for future reference R460 KEG SCALE USER MANUAL www charder com...

Страница 2: ...CTION 2 SAFETY PRECAUTIONS 2 DISPOSAL 2 LIMITED WARRANTY 3 MAINTENANCE 3 PACKAGING 4 INSTALLATION 5 OPERATION 8 ERROR MESSAGES 9 TROUBLESHOOT 9 SETTINGS CONFIGURATION 10 SETTINGS CONFIGURATION 11 SCAL...

Страница 3: ...ized personnel Verify power adapter input voltage matches the local power supply Unplug power adaptor and remove battery before assembling the scale Risk of explosion can occur if battery is replaced...

Страница 4: ...of the product use on improper voltage or current use contrary to the operating instructions abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty do...

Страница 5: ...tripping Make sure remote display s batteries are brand new and installed in the right direction Make sure platform is placed on a flat horizontal and steady surface also not surrounded by sundries M...

Страница 6: ...e scale using the supplied 15V DC power supply insert the plug from the power supply cable into the power jack on the left side of the indicator and then plug power supply into proper electrical outle...

Страница 7: ...other side of display cable into the bottom of platform flatten the cable as shown Optional Bracket Mount Installation Without Bracket via Magnetic Joint Magnetic joint behind at the back of the disp...

Страница 8: ...drill holes 2 Insert plastic tip screws included into drilled holes 3 Screw in with screw drivers and tighten to secure mounting bracket to wall 4 Route display cable through large hole in center bot...

Страница 9: ...ght is displayed D Hold This indicator will be turned on after pressing the HOLD key E Net This indicator will be turned on after pressing TARE key to tare weight of item on scale F Zero This indicato...

Страница 10: ...battery Abnormal power supply Check power cable connection ON OFF button malfunction Contact authorized Charder service agent in your area Questionable Weight or The Scale Does Not Zero External objec...

Страница 11: ...b Press TARE to enter setting c Press HOLD to view options 120S 180S 240S 300S OFF d Press TARE to select e Press HOLD 6 times to END then press TARE to save setting and restart the scale 3 Toggling t...

Страница 12: ...on the scale hold TARE button for 6 seconds Press TARE to confirm each selection kg lb lb oz Save Setting Restart the Scale Default Measure Unit Auto Turn Off Time Beep Sound Toggle Backlight Toggle F...

Страница 13: ...essing the UNIT button 3 times 2 Zero value count digit will show on display the digit is for reference only no change is needed press TARE to continue 3 Default calibration weight 100kg will blink on...

Страница 14: ...atteries Weighing Units kg lb Display 1 LCD with backlight Key Function HOLD ON OFF TARE UNIT Operating Temperature and Humidity 5 C 35 C 41 F 95 F 15 85 RH Application Mode Weighing Hold Tare Constru...

Страница 15: ...__________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________________________...

Страница 16: ...B digital device pursuant to Part 15 of the FCC Rules Charder Electronic Co LTD No 103 Guozhong Rd Dali Dist Taichung City 41262 Taiwan R O C www charder com Tel 886 4 2406 3766 Fax 886 4 2406 5612 20...

Отзывы: