Charder MG 4800 Скачать руководство пользователя страница 5

 

I. Safety Notes 

 

Thank you for choosing this Charder Medical device. It is designed to be 
easy and straightforward to operate, but if you encounter any problems 
not addressed in this manual, please contact your local Charder service 
partner. 
 
Before beginning operation of the device, please read this user manual 
carefully, and keep it in a safe place for reference. It contains important 
instructions regarding installation, proper usage, and maintenance. 
 

Intended Use 

This device is intended to measure the handgrip of subjects, for diagnosis 
of strength-related issues by professionals. 
 

General Handling 

 

Ensure the correct spring is installed before usage. 

 

Make sure the display shows zero before use. The device is designed 
to detect when a stable force has been achieved, and the indicator 
will beep to indicate that the reading can be taken. 

 

Safety Instructions 

Before putting device into use, please read this user manual carefully. It 
contains important instructions for installation, usage, and maintenance 
of device. 
 
The manufacturer shall not be liable for damages caused by failure to 
heed the following instructions: 
 

 

Batteries should be kept away from children. If swallowed, promptly 
seek medical assistance. 

 

Expected service life: 5 years. 

 

Always comply with appropriate regulations when using electrical 
components under increased safety requirements. 

 

Observe permissible ambient temperatures for use 

 
Environmental 

 

All batteries contain toxic compounds; batteries should be disposed 
of via designated competent organizations. Batteries should not be 
incinerated. 

 

Содержание MG 4800

Страница 1: ...1 USER MANUAL MG4800 Handgrip Dynamometer Please keep the instruction manual at hand all the time for future reference...

Страница 2: ...collection for waste of electrical and electronic equipment in accordance with Directive 2002 96 EC Manufacturer of medical device Manufacturing year of medical device Carefully read user manual befor...

Страница 3: ...national copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liable for any damage caused by a failure...

Страница 4: ...Batteries 8 III Display and Key Functions 9 IV Using Device 10 A Correct Grip 10 B Incorrect Grip 12 C Mode Switching 13 D Real Mode 14 E Count Mode 15 F AVG Mode 16 G Max Mode 17 V Product Specificat...

Страница 5: ...zero before use The device is designed to detect when a stable force has been achieved and the indicator will beep to indicate that the reading can be taken Safety Instructions Before putting device...

Страница 6: ...roof of purchase No responsibility shall be accepted for damage caused through any of the following reasons unsuitable or improper storage or use incorrect installation or commissioning by the owner o...

Страница 7: ...ock or injury as well as adversely affect the precision of measurements Do not place the device in direct sunlight or in close proximity to an intense heat source Excessively high temperatures may dam...

Страница 8: ...ounter clockwise to loosen 2 Insert new CR 2450 lithium battery 3 Secure battery cover rotate clockwise to tighten NOTE If device is to be placed in storage for extended period of time e g 3 months pl...

Страница 9: ...device is off press to power on Press to zero value Press and hold for 3 seconds to turn off NOTE please release device do not squeeze before zeroing value Mode press to toggle between different mode...

Страница 10: ...10 IV Using Device A Correct Grip...

Страница 11: ...11...

Страница 12: ...12 B Incorrect Grip...

Страница 13: ...d off in any other mode it will start in that mode the next time it is powered on Real time display and Unit setup Counts the number of times subject reaches target force Measures maximum force exerte...

Страница 14: ...14 D Real Mode Real Mode is a dynamic mode The force value will fluctuate according to force exerted during usage Real Time Display Release Grip Release kg lb setup...

Страница 15: ...15 E Count Mode Count Mode sets a target grip force to be achieved by the subject Grip force must reach target goal in order to be counted SETUP TARGET GRIP FORCE COUNTING OPERATION...

Страница 16: ...hands Ex Subject grips device with left and right hand Physician presses SET to calculate the average value of the last two usages NOTE force must exceed 2 kg to be registered 1st 2nd Calculate avera...

Страница 17: ...hand Percentage goal is set Subject then grips using left hand and device will evaluate if grip strength exceeds defined percentage of last measurement If gripping force is less than 31 of last use r...

Страница 18: ...Force over zero Force is over limit when device is powered on Ensure nothing is pushing on device and power on again If problem persists please contact distributor Counting Error too low Force is unde...

Страница 19: ...lb Unit kg lb LCD Screen 0 5 inch LCD screen 4 digits Dimensions Overall 212 W x 55 D x 101 H mm Grip Span 64 mm Device Weight 0 4 kg Key Functions On Off Zero Mode Set Data Transmission Power Supply...

Страница 20: ...irective 2014 30 EU Low Voltage Directive 2014 35 EU FCC Class B Declaration of Conformity This device complies with the limits for a Class B digital device persuant to Part 15 of the FCC rules Manufa...

Отзывы: