Charder HM80P Скачать руководство пользователя страница 6

 

the unit, Charder shall either repair the fault, or supply a 
replacement unit. Should the repairs or replacement delivery fail, 
statutory provisions shall be valid. The period of warranty shall be 
two years, beginning on the date of purchase. Please retain your 
receipt as proof of purchase. 

 

No responsibility shall be accepted for damage caused through any 
of the following reasons: unsuitable or improper storage or use, 
incorrect installation or commissioning by the owner or third parties, 
natural wear and tear, changes or modifications, incorrect or 
negligent handling, chemical, electrochemical, or electrical 
interference, unless damage is attributable to negligence on the part 
of Charder. 

 

This device does not contain any user-maintained parts. All 
maintenance, technical inspections, and repairs should be conducted 
by an authorized Charder service partner, using original Charder 
accessories and spare parts. Charder is not liable for any damages 
arising from improper maintenance or usage. Dismantlement of the 
device will void the warranty. 

 

Incident Reporting 

 

Any serious incident that has occurred in relation to the device 
should be reported to the manufacturer, EU representative (if device 
is used in EU member state), and competent authority of 
user/subject's member state.

Содержание HM80P

Страница 1: ...1 USER MANUAL HM80P Portable Height Meter Please keep the instruction manual at hand all the time for future reference...

Страница 2: ...al device Indicates that device conforms to Regulation EU 2017 745 Four digit number refers to Notified Body Manufacturing year of medical device Indicates that device is a medical device Device catal...

Страница 3: ...rnational copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liable for any damage caused by a failur...

Страница 4: ...afety Notes 5 A General Information 5 II Installation 7 A Parts 7 III Using Device 8 A Left handed usage 8 B Right handed usage 9 IV Product Specifications 10 A Device Information 10 V Declaration of...

Страница 5: ...ling Device should be placed on stable flat solid non slippery surface Ensure all parts are properly locked and tightened before operating the device Safety Instructions Before putting device into use...

Страница 6: ...incorrect or negligent handling chemical electrochemical or electrical interference unless damage is attributable to negligence on the part of Charder This device does not contain any user maintained...

Страница 7: ...7 II Installation A Parts 1 Left head piece 1 2 Left rod 1 3 Right rod 1 4 Right head piece 1 NOTE one side displays cm the other side displays inches...

Страница 8: ...e A Left handed usage 1 Fix right head piece at 0 cm 2 Straighten infant s feet 3 Slide left head piece until it touches the soles of the infant s feet 4 The reading on the left head piece is the leng...

Страница 9: ...handed usage 1 Fix left head piece at 0 cm 2 Straighten infant s feet 3 Slide right head piece until it touches the soles of the infant s feet 4 The reading on the right head piece is the length of t...

Страница 10: ...80P Height Measurement Range 10 80 cm 3 15 16 31 1 2 in Graduation 1 mm 1 16 in Accuracy 10 mm Dimensions Overall 890 W x 330 D x 100 H mm Device Weight 0 7 kg Operation Temperature Humidity 5 35 Opti...

Страница 11: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...

Страница 12: ...visions of the below stated directives 93 42 EEC as amended by 2007 47 EC Medical Device Directive Please see separate document showing on sticker of device for above CE marking Authorized EU Represen...